• Title/Summary/Keyword: surface sterilization

Search Result 127, Processing Time 0.023 seconds

Manufacture of Sterilizing Media with Shell Powder and It's Application to the Filter of Water Clarifier (패각분말을 이용한 살균성 메디아의 제조 및 정수기용 필터에 대한 응용)

  • Shin, Choon-Hwan
    • Journal of Environmental Science International
    • /
    • v.15 no.11
    • /
    • pp.1027-1034
    • /
    • 2006
  • Antimicrobial powder was made by exchanging silver ion on calcined oyster shell. On the purpose of application to water clarifier, bail-type media mixed with antimicrobial powder and $0{\sim}30%$ white kaoline were made. The sterilization effect, pore size distribution and zeta potential was tested to indicate the condition for the media of water clarifier. From these tests, it was confirmed that this media have an excellent sterilization power on $G^-\;and\;G^+$ germs. As the concentration of the exchanged silver ion increased, the surface charge density of the anions on the surface of the media also increased. The surface pore size decreased with the concentration of silver ion and 20% more white kaoline ratio. Consequently, mixing ratio of white kaoline would appear to indicate the optimun condition as media have sterilization power.

The Effect of Heat Sterilization on the Surface Topography and the Tensile Properties in Various Nickel Titanium Wires Including a Korean Product (열멸균과정이 nickel titanium호선의 기계적 성질과 표면상태에 미치는 영향)

  • Kim, Byoung-Ho;Nahm, Dong-Seok;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.28 no.6 s.71
    • /
    • pp.927-935
    • /
    • 1998
  • The purpose of this study is to investigate the changes of mechanical properties and surface topography of various nickel titanium wires after heat sterilization for recycling with quantitative method. The materials used were four kinds of nickel titanium orthodontic wires including a Korean product. Experimental specimens were treated with two kinds of heat sterilization methods ; dry heat ($180^{\circ}C$, 60min) and autoclave ($121^{\circ}C$, 15-20psi, 30min). Mechanical properties were evaluated by tensile test with Instron 4466 (load cell capacity:.1000 kg, cross head speed:5mm/min, grip distince:40mm in room temperature). Surface topography of various wires was compared with each other qualitatively by using scanning electron microscopy and quantitatively by using profilometer. The findings were analyzed statistically with student t-tests. The results were as follows; 1. Neither method of heat sterilization had any effects on tensile properties of the nickel-titanium wires used in this experiment. 2. Before heat sterilization, the surface smoothness was highest in Optimalloy, followed by Align and Sentalloy, with NiTi showing the lowest smoothness value. 3. In surface topography, Align and Optimalloy were not influenced by heat sterilization. NiTi, on the other hand, had increased roughness after dry heat sterilization and Sentalloy showed the same tendency after each of the two heat sterilization procedures.

  • PDF

Determination of Optimum Sterilization Condition for the Production of Retort Pouched Curry Sauce (레토르트 카레 소스 생산을 위한 최적살균 조건의 설정)

  • Chung, Myong-Soo;Cha, Hwan-Soo;Koo, Bon-Youl;Ahn, Peong-Ug;Choi, Chun-Un
    • Korean Journal of Food Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.723-731
    • /
    • 1991
  • In order to optimize sterilization conditions of retort pouched curry sauce, sterilization processes for eighteen conditions by varying temperature, time and method were conducted through $3^{2}{\times}2^{1}$ experimental factorial design. Quality evaluations before and after sterilization included measurements of vitamin (niacin) retention, pH and color differences, and organoleptic test(taste, color and viscosity). $F_{o}$ values were also measured at each condition. Product qualities were mainly affected by sterilization temperature and time, whereas sterilization method had no significant effect. Effect of sterilization time on product qualities was higher than that of sterilization temperature. From the response surface analysis, an optimum range of sterilization condition simultaneously satisfying desired specifications was determined to be $123.5^{\circ}C$, 21.5 min to $127.5^{\circ}C$, 17.0 min. In this range, the sterility($F_{o}$ value) at a cold point during sterilization was approximately 15.0 min.

  • PDF

Reuse of Oyster Shell Waste as Antimicrobial Water Treatment Agent by Silver Ion Exchange

  • Jo, Myung-Chan;Byeong-II Noh;Shin, Choon-Hwan
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.4 no.3
    • /
    • pp.185-193
    • /
    • 2000
  • A water treatment agent with antimicrobial activity(Ag-Os) was created by exchanging silver ion($Ag^{+}$) on calcined oyster shell powder. The desorption of the exchanged silver ion was negligible, thereby indicating a stable antimicrobial water treatment agent. The sterilization effect of Ag-Os on underwater microorganisms was then investigated. An MIC (Minimum Inhibitory Concentration) test result indicated that Ag-Os had an excellent sterilization effect on G-germs, such as Escherichia coli and Pseudomonas aeruginosa. Most germs were annihilated with an Ag-Os concentration of 200 ppm and contact time of 60 minutes. The sterilization effect was mainly dependent on the contact time. The zeta potential of the Ag-Os powder adsorbed on sand was measured relative to the concentration of exchanged silver ion. As the concentration of the exchanged silver ion increased, the surface charge density of the anions on the surface of the Ag-Os powder adsorbed on sand also increased. Accordingly, this result indicated that a higher silver ion than ion exchange capacity was present on the particle surface due to adsorption. Consequently, this increased concentration of exchanged silver ion would appear to significantly enhance the sterilization power.

  • PDF

Optimum Sterilization Conditions and Quality Characteristics of the Retort-Sterilized Crab Analog (레토르트 Crab Analog의 살균 최적화 및 품질 특성)

  • Yun, Jae-Ung;Oh, Dong-Hun;Kim, Byeong-Gyun;An, Byung-Soo;Choi, Jong-Duck;Oh, Kwang-Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.44 no.1
    • /
    • pp.31-36
    • /
    • 2011
  • This study developed a normal temperature-circulatable retort-sterilized crab analog (RSCA) with a long shelf-life by retort sterilization. We examined the optimum sterilization conditions and quality characteristics of the RSCA. A central composite design for response surface methodology (RSM) was adopted to optimize of the retort sterilization. The central composite design consisted of 11 samples: four factorial points, four star points, and three central points. The sterilization temperature and $F_0$-value for retort sterilization were the independent variables, and the shearing force, whiteness, and sensory score for texture were the dependent variable. The RSM analysis of the multiple response optimization for the RSCA using the Minitap statistical programing gave an $F_0$-value of 3.3 min. at $117.5^{\circ}C$. The RSM analysis also indicated that the sterilization temperature during retort sterilization was the most influential factor, while the $F_0$-value had little effect on the quality of the RSCA. The moisture, pH and volatile basic nitrogen contents of the RSCA product were 73.1%, 7.3 and 17.2 mg/100 g, respectively, and viable cells count was >18 CFU/g. And sensory quality characteristics of this RSCA was similar to those of a commercial crab analog.

Assessment of decontamination of gutta-percha cone and the change of surface texture after rapid chemical disinfection (화학소독제 처리 후 가타파차 콘의 멸균 효과 및 표면 성상의 변화 평가)

  • Pang, Nan-Sim;Jung, Il-Young;Yu, Yoon-Jung;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.2
    • /
    • pp.133-139
    • /
    • 2006
  • The purposes of this study were firstly to identify the microbial species on gutta-percha (GP) cones exposed at outpatient clinics using polymerase chain reaction, and secondly to evaluate the rapid sterilization effect of two chemical disinfectants at chair side. It also evaluated the alteration of surface texture of GP cones after 5-min soaking into two chemical disinfectants. A total of 100 GP cones from two endodontic departments were randomly selected for microbial detection using PCR assay with universal primer. After inoculation on the sterilized GP cones with the same microorganism identified by PCR assay, they were soaked in two chemical disinfectants: 5% NaOCl and 2% chlorhexidine for 1, 3, 5, and 10 minutes. The sterilization effect was evaluated by turbidity and subculture. The change of surface textures using a scanning electron microscope was also examined after 5 min-soaking in two chemical disinfectants. Results showed that four bacterial species were detected in 17 GP cones, and all the species belonged to the genus Staphylococcus. Two chemical disinfectants were effective in sterilization with just 1 minute soaking. On the SEM picture of NaOCl-soaked GP cone, a cluster of cuboidal crystals was seen on the cone surface. Present data demonstrate that two chemical disinfectants are useful for rapid sterilization of GP cone just before obturation at chair side, while CHX-soaked GP cone has cleaner surface without crystal precipitation than that of NaOCl-treated cone.

Experimental Study on the Irradiation and Surface Sterilization Effect of Ultra Violet Ray in Air Conditioning System (공조시스템에서 UV Ray의 조사 및 표면살균성능에 관한 실험적 연구)

  • 홍진관
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.3
    • /
    • pp.250-257
    • /
    • 2004
  • Recently, the use of UVC lamps inside building air-conditioning system has been increasing in both medical and nonmedical buildings for the control of environmental microorganisms. In the present study, irradiance performance test of UVC lamp was carried out and surface sterilization effect of UV ray was investigated by using UV ray irradiation experimental chamber and pilot system. Experimental results show that the effective irradiance of UVC lamp is strongly dependent on air velocity and temperature with exception of relative huminity in air-conditioning system. An individual microbiological kill effectiveness experiment also shows that the fractional kill of two microbiological samples such as E. Coli and Legionella is roughly the same as the estimated fractional kill in the case of chamber test and pilot system test.

EFFECT OF DIFFERENT STERILIZATION METHODS ON THE SURFACE MORPHOLOGY OF PPDO-hybrid-PLGA NANOFIBER SCAFFOLD AND ATTACHMENTS OF PC12 CELL (다양한 소독방법이 PPDO-hybrid-PLGA nanofiber scaffold의 형태와 세포부착에 미치는 영향에 관한 연구)

  • Lee, Ju-Hyon;Min, Hyun-Gi;Jung, Ju-Young;Kang, Na-Ra
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.6
    • /
    • pp.635-639
    • /
    • 2008
  • Objectives : the effect of different sterilization methods on the surface morphology of PPDO-hybrid-PLGA nanofiber scaffold and attachments of PC12 cell were investigated. Methods : Poly (p-dioxone)-hybrid-Poly (lactide-glycolide) (PPDO-hybrid-PLGA) nanofiber scaffold, fabricated in a tube form with 1.5 mm internal diameter, 0.2 mm thickness and 5 mm length, was prepared using electrospinning method. To study the surface morphology using SEM, The study group and control group in respective were; Control:Non-sterilized scaffold, Group I:scaffold sterilized with 70% Alcohol, Group II: scaffold sterilized with Ethylene Oxide at $65^{\circ}C$, and Group III: scaffold sterilized with Ethylene Oxide at $37^{\circ}C$. To investigate viability of the PC12 cell on the scaffold, The study group and control group in respective were; Control: sterilized with 70% Alcohol, Group I: sterilized with Ethylene Oxide at $65^{\circ}C$, and Group II: sterilized with Ethylene Oxide at $37^{\circ}C$. Results : 1. The surface morphology was slightly changed in Group I, II and Group III, compared with control. 2. The attachment of PC12 cells in Group I, II was not higher than in control Discussion : The attachment of PC12 cell is not influenced by different sterilization methods.

A Study of Homogeneous Sterilization of Micro-sized Food Powder by Rotatable Low-Temperature Plasma System (회전형 저온 플라즈마 시스템을 이용한 분말식품의 균일한 살균 연구)

  • Kim, Myung Chan;Park, Duck Mo;Han, Jin Soo;Woo, In Bong;Kim, Dong Hoo;Jang, Seong Eun;Yoon, Chan Suk;Kim, In
    • The Korean Journal of Food And Nutrition
    • /
    • v.31 no.2
    • /
    • pp.301-307
    • /
    • 2018
  • In this study, a relatively effective process is used to sterilize Escherichia coli on the surface of micro-sized calcium citrate powder using nitrogen and argon as process gases in a low-temperature vacuum plasma treatment. The purpose of this study is to confirm and to introduce the effectiveness of homogeneous surface treatment for the sterilization of fine inorganic powder by the rotatable low-temperature RF plasma system designed by ourselves. The results of the test using 3M petrifilm showed that there were no remarkable spots in the case of the surface of plasma treated powder, whereas the untreated powder showed many blue spots, which indicating that the E. coli was alive. After 5 days, in the same samples, the blue spots were seen to be larger and darker than before, while the plasma-treated powder showed no changes. The results from FE-SEM analysis showed that the E. coli was damaged and/or destroyed by reactive species generated in the plasma space, resulting in the E. coli being sterilized. Furthermore, the sterilization effects according to the selected parameters ($N_2$ and Ar; flow rate 30 and 50 sccm) adapted in this study were mutually similar, regardless of such different process parameters, and this indicates that homogeneous treatment of powder surfaces could be more effective than conventional methods. Therefore, the plasma apparatus used in this study may be a practical method to use in a powerful sterilization process in powder-type food.

Sterilization of Bacteria and Fungi in Cultural Heritages using Atmospheric Pressure Plasma Jet System (대기압 플라즈마 제트 시스템을 이용한 문화재 내 세균류 및 진균류의 살균)

  • Jo, Sung-Il;Park, Dong-Min;Lee, Byeong Hoon;So, Myoung-Gi;Ha, Suk-Jin;Jeong, Goo-Hwan
    • Journal of the Korean institute of surface engineering
    • /
    • v.53 no.6
    • /
    • pp.285-292
    • /
    • 2020
  • Ancient cultural heritage made up of wood and organic fibers have been easily disintegrated or decomposed by various microorganisms like bacteria and fungi. Here, we demonstrate the effectiveness of an atmospheric pressure plasma jet (APPJ) system to sterilize the microorganisms in tangible cultural heritage. We collected several specimens from the surface of ancient documents and wooden artifacts. Finally, two bacteria and two fungi were prepared and sterilized using the APPJ treatment. The APPJ system is beneficial to its simple apparatus, quick operation time, and cost-effectiveness. Bacteria were almost sterilized within only 1 min treatment using 15 % O2 and applied bias voltage of 100 V. In case of the fungi, sterilization rate reached over 83 % but difficult to reach over 90 % even 10 min treatment. According to the plasma diagnostics using optical emission spectroscopy, it was found that the reactive oxygen species such as OH groups are critical for sterilization of microorganisms. Although further efforts should be performed, we believe that efficient sterilization could be realized by the simple, quick, and portable APPJ treatment system.