Evaluation for the simultaneous Removal of Organic Matters and Nutrients by the RBC and tapered Aeration Processes with Bacillus sp. for the high Strength of Dairy Wastewater (바실러스 미생물을 이용한 고농도 유가공 폐수처리에 있어서 유기물질과 영양염류의 동시제거에 대한 평가)

  • Lee, Sang-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.2
    • /
    • pp.195-202
    • /
    • 2010
  • The evaluation of organic matters and nutrients removal was investigated for the synthetic wastewater and the high strength of dairy wastewater. Two different systems were performed for this research. System A composing of a single RBC with tapered aeration was fed with the synthetic wastewater for 74 days with 173L/day of influent, 200% of internal return and 100% of sludge return for the period 1 and 2. The feed conditions were maintained 346L/day of influent, 50% of internal return and sludge return for the period 3. The dairy wastewater was introduced to evaluate treatment efficiency for system B composing of dual RBCs and tapered aeration tanks for 50 days of experimental run time, in which hydraulic rates were maintained at the constant ratios of 346L/day, 50% of internal return and 50% of sludge return. The spiral string media made of nylon fibre was attached by Bacillus sp. in RBC for both systems. The specific area of string media was $1.4m^2$/m and biomass was maintained at the concentrations of 23g/m. The synthetic wastewater was supplied by 1,800mg/L of glucose, 500mg/L of $NH_4Cl$, and 500mg/L of $KH_2PO_4$ to system A. The dairy wastewater was supplied to system B from dairy production plant. The average influent concentrations were 1,334mg/L of BOD, 2,014mg/L of CODcr, 160mg/L of T-N, and 12mg/L of T-P in system A. The average influent concentrations of parameters were 1,006 mg/L for BOD, 1,875mg/L for $COD_{cr}$, 51.6mg/L for T-N and 8.9mg/L for T-P in system B. Results indicated that removal efficiencies of BOD and $COD_{cr}$ were more than 90% however, the removal efficiency of T-N was 87%, and that of T-P was 82% for system A. Removal efficiencies were 98.5% of BOD, 91.3% of nitrogen and 89% of phosphorus for system B. The removal efficiencies of organic matters, T-N and T-P were higher in system B than in system A. The effluent quality issued by the stringent national legislations for the discharge of the high strength of dairy products wastewater can be improved using sequential RBCsand tapered aeration reactors rather than a single RBC and tapered aeration reactors with Bacillus sp.

Removal of organic Carbon, Nitrogen and Phosphorus in Wastewater based on tapered Aeration with Bacillus sp. (점감포기에 의한 바실러스 특성을 이용한 폐수의 유기물질 및 질소, 인 처리에 관한 연구)

  • Kim, Pan-Soo;Lee, Sang-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.4
    • /
    • pp.861-866
    • /
    • 2007
  • This study was conducted to investigate an aeration tank with RBC process attached Bacillus sp. known as a suitable microorganism for the removing of organic carbon, nitrogen and phosphorus. An aeration tank was based on tapered aeration because Bacillus sp. was well grown in this like environment conditions. The biofilm process with Bacillus sp. as an advanced treatment process could be a best technology for the prominent removal of organic carbon, nitrogen and phosphorus if the mechanism in the process is verified. The operation conditions of DO in the tapered aeration tank were maintained as $1.2{\sim}1.5mg/L$ in aeration tank1, as $0.3{\sim}0.5mg/L$ in aeration tank 2 and less than 0.2 mg/L in aeration tank 3, respectively. Lab-scale experiments were conducted, at room temperature, internal recycle rate was from 200% to 50% and returned sludge rate was from 100% to 50%. As a result, concentration of organic carbons, nitrogen and phosphorus in Period 1 (the time of Bacillus sp. adapted to environment) were decreased gradually. Ultimately, each removal rate in this biological experiment were TCODCr 94%, BOD 87%, T-N 85%, T-P 89% in Period 2. Hence, this process showed an excellent performance of the removal of organic carbon, nitrogen and phosphorus and this is an effective system fur treating of wastewater.

  • PDF

Sedimentation and EPS Production by the Change of Dissolved Oxygen Concentration for the Aeration Tank to treat Wastewater with Bacillus sp. (바실러스 미생물을 이용한 하수처리에서 포기조의 DO농도 변화에 따른 EPS 물질생성과 슬러지 침강성에 관한 연구)

  • Lee, Sang-Ho;Son, Han-Hyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.3
    • /
    • pp.627-631
    • /
    • 2007
  • The factors affecting on sludge sedimentation are reported as F/M ratio, ingredient, composition of influent substrate, dissolved oxygen concentration, temperature, pH, filamentous bacteria and SRT. Aeration tank applying Bacillus sp. has an important role for maintaining the dominant microorganism species to make steady progress for spore growth affecting sedimentation. This research aims to investigate the affecting factor for the sedimentation in B3 system and RABC system with aeration tank applying tapered aeration. Extracellular polymeric substances(EPS), protein and carbohydrate can be produced for the extreme condition, that is down to 0.2 mg/L of dissolved oxygen in the aeration tank. This research found out the relation between the sedimentation and the EPS production, especially the ratio of protein/carbohydrate. The spore of Bacillus sp. was formed at the low DO then microorganisms produced EPS. The results showed that the production of EPS was 109.95 mgEPS/gSS at 1.6 mg/L of DO, however it was 131.77 mgEPS/gSS at 0.5 mg/L of DO. The sedimentation was affected by protein content in EPS and the ratio of protein and carbohydrate. The settleability of sludge was not affected by the ratio of protein/carbohydrate in B3 process, meanwhile settleability was affected by the ratio of it in RABC process, respectively.

  • PDF

Bacterial Community Structure of Food Wastewater Treatment System Combined with Rotating Biological Contactor and Tapered Aeration Reactor (회전접촉장치와 점감포기 반응조를 이용한 식품폐수 처리시설의 세균군집 구조)

  • Jeong, Soon-Jae;Nam, Ji-Hyun;Bae, Woo-Keun;Lee, Dong-Hun
    • Korean Journal of Microbiology
    • /
    • v.46 no.2
    • /
    • pp.169-176
    • /
    • 2010
  • A pilot-scale wastewater treatment plant combined with rotating biological contactor and tapered aeration reactors was operated with the wastewater discharged from a food factory for 5 months. The bacterial communities of this plant were investigated by terminal restriction fragment length polymorphism (T-RFLP) and phylogenetic analysis of 16S rRNA genes. In spite of high concentration of nitrogen and phosphorus as well as organic carbon, removal efficiency of chemical oxygen demand, total nitrogen, and total phosphorus was 98%, 93%, and 95%, respectively. Bacterial community at the initial operation stage was clearly distinguished from that of the stable operation stage. The most predominant phylum in the sample of stable stage was Bacteroidetes. Major population of operation period was Haliscomenobacter, Sphaerotilus, and candidate division TM7, which were classified as filamentous bacteria. However, sludge bulking caused by these bacteria was not observed. The population that has a close relationship with Haliscomenobacter increased during the stable operation stage, emerging as the most predominant group. These results suggest that the filamentous bacteria participated in nutrient removal when using rotating biological contactor and tapered aeration reactor.

Treatment of Dairy Wastewater by the Combination of RBC and tapered Aeration (RBC와 점감포기조의 복합구성에 따른 유가공폐수 처리에 관한 연구)

  • Lee, Sang-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1733-1738
    • /
    • 2008
  • The treatment efficiency of rotating biological contactors (RBCs) for the high strength of dairy wastewater was investigated. Two different systems were conducted composing of a single RBC with tapered aeration reactors for the system A and a sequential RBCs following tapered aeration reactors for the system B. Experiments using dairy wastewater were conducted for 50 days period of time, in which hydraulic rates were maintained at the constant ratios of 346L per day and variable BOD concentrations were at the range from 1,358mg/L to 829mg/L, the $COD_{cr}$, concentration of the range were from 2,384mg/L to 1,329mg/L, the range of T-N concentrations was from 66mg/L to 38mg/L, and 50% of internal recycle and 50% of sludge return were performed. Results indicated that the removal efficiencies of the system B were higher than those of the system A. The removal efficiencies of system A for the BOD, $COD_{cr}$, T-N and T-P were 97.8%, 96.7%, 87.2% and 82%, respectively. The removal efficiencies of system B for the BOD, $COD_{cr}$, T-N and T-P were as of 98.5%, 98.5%, 91.3% and 89%.