• Title/Summary/Keyword: tiered wall

Search Result 24, Processing Time 0.029 seconds

Analysis of the Behavior of Tiered Reinforced Soil Retaining Wall Considering the Offset Distance by Surcharge Load (상재하중 이격거리에 따른 다단식 보강토옹벽의 거동특성 분석)

  • Han, Jung-Geun;Kim, Ji-Sun;Hong, Ki-Kwon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.10 no.4
    • /
    • pp.31-40
    • /
    • 2007
  • Recently, the scale in the field of reinforced soil retaining wall has been grown up like tiered reinforced soil retaining wall. However, there have been increasing number of collapse accidents and large scale of collapse. The design manual adopted in the construction fields have been inconsistent in tiered reinforced soil retaining wall. Therefore, this study performed finite element analysis on 90 cases and analyzed characteristic behavior of lower wall which was one of the effect factors on the stability of tiered reinforced soil retaining wall. The facing displacement of each walls and the behavior of the whole ground were interpreted by the numerical analysis depending on the lower offset distance by the upper wall as well as the upper offset distance by the surcharge load. The results showed that the behavior of tiered reinforced soil retaining wall was differed by condition of surcharge load and each offset distance was found to be important factor.

Behavior of Soil-reinforced Retaining Walls in Tiered Arrangement (계단식 보강토 옹벽의 거동 특성)

  • Yoo, Choong-Sik;Kim, Joo-Suk
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.3
    • /
    • pp.61-72
    • /
    • 2002
  • This paper presents the results of investigation on the behavior of soil-reinforced segmental retaining walls in tiered arrangement using the finite element method of analysis. 2D finite element analyses were performed on tiered walls with two levels of offset distance. Cases with equivalent surcharge as suggested by the NCMA design guideline were additionally analyzed in an attempt to confirm the appropriateness of the equivalent surcharge model adopted by NCMA. Deformation characteristics of a tiered wall with small offset distance suggest a compound mode of failure and support current design approaches requiring a global slope stability analysis for design. Also revealed is that the interaction between the upper and lower walls significantly affects not only the performance of the lower wall but also the upper wall, suggesting that the upper walls should also be designed with due consideration of the interaction.

High MSE wall design on weak foundations

  • Mahmoud Forghani;Ali Komak Panah;Salaheddin Hamidi
    • Geomechanics and Engineering
    • /
    • v.36 no.4
    • /
    • pp.329-341
    • /
    • 2024
  • Retaining structures are one of the most important elements in the stabilization of excavations and slopes in various engineering projects. Mechanically stabilized earth (MSE) walls are widely used as retaining structures due to their flexibility, easy and economical construction. These benefits are especially prominent for projects built on soft and weak foundation soils, which have relatively low resistance and high compressibility. For high retaining walls on weak foundations, conventional design methods are not cost-effective. Therefore, two alternative solutions for different foundation weakness are proposed in this research: optimized multi-tiered MSE walls and single tier wall with foundation improvement. The cost optimization considers both the construction components and the land price. The results show that the optimal solution depends on several factors, including the foundation strength and more importantly, the land price. For low land price, the optimized multi-tiered wall is more economical, while for high land price (urban areas), the foundation improvement is preferable. As the foundation strength decreases, the foundation improvement becomes inevitable.

A Case Study on Behavior of High-Raised Reinforced Soil Wall (고성토 보강토옹벽의 거동에 관한 사례연구)

  • Cho, Sam-Deok;Lee, Kwang-Wu;Lee, Hoon-Yeon;Chang, Ki-Soo
    • Journal of the Korean Geosynthetics Society
    • /
    • v.5 no.4
    • /
    • pp.35-42
    • /
    • 2006
  • This paper describes a field experience on geogrid-reinforced soil walls rising up to 29.5m in height. Since experiences of design and construction on very high-raised geogrid reinforced soil wall were limited, thorough design and construction management was performed for safe construction of the wall. Regarding design of the wall, both internal and external stabilities were examined based on the design guideline specified by FHWA and overall slope stability analyses were performed by using Bishop simplified method. Moreover, a series of instrumentations were performed. The results of instrumentation for two tiered reinforced soil wall showed that not only the deformations of both the wall face and the reinforcement but also the horizontal earth pressures acting on the wall facing were very small. These results indicate that the reinforced soil wall technology can be applied successfully for high-raised tiered wall more than 20m heights and FHWA design guideline is very conservative for that large wall.

  • PDF

A Study on Comparison of Korean and Western Furniture Terminology - Focusing on Traditional Cupboard - (한국과 서구의 가구 용어 비교 연구 - 전통 찬장을 중심으로 -)

  • Moon, Sun-Ok;Jang, Hyun-Young
    • Journal of the Korea Furniture Society
    • /
    • v.24 no.4
    • /
    • pp.389-399
    • /
    • 2013
  • This study focuses a comparison of Korean and Western Furniture culture on traditional cupboard terms to make the people understand and distinguish the form of the various Korean and Western cupboard made by the craftsmanship before the industrial Revolution. As the result, the Korean cupboard shows Kangwon Chanjang/cupboard, Gyeonggi Chanjang/cupboard by the local name, dwiju Chanjang/cupboard, three-tiered Chanjang/cupboard, four-tired Chanjang/cupboard, two-tiered Chantak/cupboard, three-tiered Chantak/cupboard in the terms of the form. Korean cupboards are called Chanjang and Chantak. The Western cupboard shows cupboard, buffet, livery cupboard, cupboard-bed, corner cupboard, court cupboard, turkey-breast cupboard, pot cupboard, press, press cupboard, hall cupboard, sideboard, hunt sideboard, huntboard, cabinet, corner cabinet, writing cabinet, art cabinet, china cabinet, dresser, safe, meat safe, wall closet, wall cupboard, hanging corner cupboard, food cupboard in the terms of the various forms.

  • PDF

The role of wall configuration and reinforcement type in selecting the pseudo-static coefficients for reinforced soil walls

  • Majid Yazdandoust;Amirhossein Rasouli Jamnani;Mohsen Sabermahani
    • Geomechanics and Engineering
    • /
    • v.35 no.5
    • /
    • pp.555-570
    • /
    • 2023
  • In the current study, a series of experimental and analytical evaluations were performed to introduce the horizontal pseudo static coefficient (kh) as a function of the wall configuration and the reinforcement type for analyzing reinforced soil walls. For this purpose, eight shaking table tests were performed on reduced-scale models of integrated and two-tiered walls reinforced by metal strip and geogrid to determine the distribution of dynamic lateral pressure in the walls. Then, the physical models were analyzed using Mononobe-Okabe method to estimate the value of kh required to establish the dynamic lateral pressures similar to those observed in shaking table tests. Based on the results, the horizontal pseudo static coefficient and the position of resultant lateral force (R) were introduced as a function of the horizontal peak ground acceleration (HPGA), the wall configuration, the reinforcement type as well as maximum wall displacement.

Geosynthetic-Reinforced Segmental Retaining Walls in Tiered Arrangement - Case Study and Field Trial Wall Instrumentation (다단식 보강토 옹벽의 설계 - 사례연구 및 시험시공)

  • Yoo, Chung-Sik;Jung, Hyuk-Sang
    • Journal of the Korean Geosynthetics Society
    • /
    • v.3 no.1
    • /
    • pp.27-36
    • /
    • 2004
  • This paper presents the results of stability analyses on soil-reinforced segmental retaining walls in a tiered arrangement. Four different walls were examined to investigate the appropriateness of their designs within the context of the current design guidelines based on limit equilibrium. Slope stability analysis against the compound failure mode, which is frequently ignored during design, was also performed based on the method recommended by FHWA design guidelines. Also presented are the results of instrumentation on a full-scale field trial wall constructed as part of this study. The implications of the findings from this study are discussed.

  • PDF

Failure Mechanism of Geosynthetic-Reinforced Segmental Retaining Wall in a Tiered Configuration (계단식 보강토옹벽의 파괴 메카니즘 연구)

  • Yoo, Chung Sik;Jung, Hyuk Sang;Lee, Bong Won
    • Journal of the Korean Geosynthetics Society
    • /
    • v.3 no.4
    • /
    • pp.13-19
    • /
    • 2004
  • This paper presents the results of an investigation on the failure mechanism of geosynthetic-reinforced segmental retaining walls in tiered arrangement using reduced-scale model tests. In this laboratory model tests, a reduced scale model of the full-scale geosynthetic-reinforced wall which was constructed in Geotechnical Experimental Site at Sungkyunkwan University was used to perform a study on the failure mechanism. In order to a high degree of realism, the geometry of the wall and the material properties were selected applying Similitude Laws was used to perform laboratory model tests. And contrary to the previous failure tests with various surcharge pressures, the failure by the tired wall weight was observed. Primary variables considered in the model tests include the different offset distance between the tiers and the different reinforcement length in the lower tier and as a result of the parametric study, a different failure pattern was observed.

  • PDF

Design Case Study of Geosynthetic Reinforced Segmental Retaining Walls in Tiered Configuration (다단식 보강토 옹벽의 설계 사례 연구)

  • 유충식;허병주
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.115-125
    • /
    • 2003
  • This paper presents the results of design case study on soil-reinforced segmental retaining walls in tiered configuration. Six different field walls were examined to investigate the appropriateness of their designs within the context of the current design guidelines based on limit equilibrium. Slope stability analysis against the compound failure mode, which is frequently ignored during design, was additionally performed based on the method recommended by FHWA design guidelines. The results indicate that the as-built designs of some of the walls examined do not meet the minimum factors of safety for the external and Internal stabilities, and for the compound failure mode. The implications of the findings from this study are discussed.

Importance of global slope stability analysis in design of geosynthetic reinforced walls in tiered configuration (계단식 보강토 옹벽 설계시 사면안정해석의 중요성)

  • Yoo, Chung-Sik;Kim, Sun-Bin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.176-183
    • /
    • 2008
  • This paper highlights the importance of carrying out global slope stability analysis as part of design calculations for geosynethetic walls in tiered configuration. Four design case histories were selected to examine the appropriateness of their design by performing additional slope stability analyses using the shear strength reduction method with in the frame work of finite element analysis. The results indicated that all of the walls examined, which were designed to meet the current design guide lines, did not satisfy the global slope stability requirement, and that longer reinforcements are required in the upper tiers to achieve the minimum factor of safety. Practical implications of the findings are discussed.

  • PDF