• Title/Summary/Keyword: total sound pressure level

Search Result 55, Processing Time 0.023 seconds

Characteristic of Road Traffic Noise According to Road Vertical Alignment (도로 종단선형에 따른 도로교통 소음 특성 분석)

  • Moon, Hak Ryong;Han, Dae Cheol;Kang, Won Pyoung
    • International Journal of Highway Engineering
    • /
    • v.15 no.4
    • /
    • pp.95-105
    • /
    • 2013
  • PURPOSES: The purpose of this study is to research the influence of road traffic noise by road slope through the analysis of the field road traffic noise and determine consideration of road slope in the case of appling active noise cancellation. METHODS: This study measures vehicle's noise by the NCPX method at the three field sections such as uphill, downhill, and flatland. Total sound pressure and sound pressure level by the 1/3 octave band frequency are calculated through the raw field data. Total sound pressure level is compared by ANOVA test and T test statistically. The results obtained are compared in accordance with the road slope and the progress of the uphill section. RESULTS : The noise characteristic of early, medium, and last parts of uphill was found to be consistent when the vehicle was travelling uphill section. The result of statistical test, it was shown that total sound pressures are not different each other. According to the comparison by the geometry, sound pressure of the uphill section was higher than those of the flatland and downhill section in high frequency band. By the result of statistical test, total sound pressure are different according to geometry in the case of high vehicle speed. In the comparison result by road slope, each sound pressure level was found to be consistent in total frequency. However, total sound pressure proportionally increased according to road slope. CONCLUSIONS: It is found that the effect of road slope on noise generation was little in this experimental sites.

Numerical Investigation of Performance Characteristics for Cooling Tower Axial Fans with Sweep (스윕을 가진 냉각탑용 축류홴의 성능 특성에 관한 수치해석적 연구)

  • Oh, K.J.
    • Journal of Power System Engineering
    • /
    • v.13 no.4
    • /
    • pp.31-37
    • /
    • 2009
  • The purpose of this numerical study was to investigate performance characteristics for cooling tower axial fans with sweep. Performance data for the fans with various sweep angles were obtained in terms of the setting angle at a constant flow rate. Viscous flow calculations were carried out to obtain Performance data of the total pressure rise and hydraulic efficiency. A solution of the Ffowcs Williams-Hawkings equations was used to calculate the sound pressure level at three times fan diameter away from the fan. The calculated performance data well represented performance characteristics of the cooling tower axial fan. The total pressure rise and hydraulic efficiency at the same setting angle decreased with sweep angle. Sound pressure level slightly decreased for the fan with a sweep angle of 10 degree. No significant effect of the sweep geometry was found on the sound pressure level.

  • PDF

Analysis of Vehicle Noise Effect by Microphone Position and Road Geometry (도로 기하구조에 따른 차량 Microphone 위치별 소음 영향 분석)

  • Moon, Hak Ryong;Han, Dae Cheol;Kang, Won Pyoung
    • International Journal of Highway Engineering
    • /
    • v.15 no.4
    • /
    • pp.75-83
    • /
    • 2013
  • PURPOSES: The purpose of study is to understand the characteristic of driving noise from the front and rear tire for effective active noise cancellation application. METHODS : As literature review, noise measurement methods were reviewed. Noise measurement conducted at three kind of section by road slope using CPX(Close Proximity Method). Noise data was compared by total sound pressure level and 1/3 octave band frequency sound pressure level. Also, each section was compared by T-test using SPSS. RESULTS : In the case of the uphill section, it was shown that the sound pressure level of the front tire at Sugwang-Ri and Sinchon-RI sections was higher than that of the rear tire in low and high frequency band. In the case of high slope section of Sangsaek-Ri, the sound pressure level of the front tire was higher than that of the rear tire in high frequency. Also, in the case of the downhill section, it was shown that the sound pressure level of the front tire at Sugwang-Ri and Sinchon-RI sections was higher than that of the rear tire in low frequency band. However, the sound pressure levels of both the front and rear tires were approximately the same in the high slope section of Sangsaek-Ri. The result of T-test showed that total sound pressures of the front and rear tires were not different from each other in the case of high slope and high speed. CONCLUSIONS: Road slope was not an important variable for effective active noise cancellation.

Constructed Sound Field of an Induction Motor Using Cylindrical Acoustic Holography (원통형 음향 홀로그래피를 이용하여 구성한 유도전동기의 방사 음장)

  • 김시문;김양한
    • Journal of KSNVE
    • /
    • v.7 no.6
    • /
    • pp.919-929
    • /
    • 1997
  • Induction motors are used in many areas to transform electrical energy to mechanical energy. In the design of an induction motor, not only energy efficiency but also noise becomes an important factor. To effectively address the noise problem, it will be convenient if one can see where and how noise is generated and propagated. In this study sound radiation by an induction motor is visualized using cylindrical acoustic holography. To minimize the bias error by window effect Minimum Error Window(MEW) is used. Its performance is verified by numerical simulations. Based on these theoretical understanding, sound pressure measurement with an induction motor are performed. Not only sound radiation are visualized but sound pressure level and sound power level are also estimated. Results show that the main source is located at nearly bottom part of the motor and the total sound pressure level is 49dB, which satisfies the guideline value suggested by the KS C 4202.

  • PDF

A Study for Comparing Road Noise by Surface Types using NCPX (NCPX를 이용한 도로 표층 유형별 노면 소음 비교 연구)

  • Kang, Won Pyoung;Moon, Hak Ryong
    • International Journal of Highway Engineering
    • /
    • v.15 no.6
    • /
    • pp.61-68
    • /
    • 2013
  • PURPOSES : The purpose of this study is to study the noise reducing effect of Micro Surfacing by comparing general asphalt, longitudinal tining and Slurry Seal. METHODS : This study measures vehicles' noise of each section by the NCPX method that can measure noise between the road surface and the tire at the field. Total sound pressure and sound pressure level by the 1/3 octave band frequency are calculated through the field data of each section. Total sound pressure level is compared by ANOVA test statistically. After ANOVA test, post-hoc test is conducted to know mean difference of surface type by Tukey. RESULTS : As the result of CPB analysis to confirm sound pressure levels by frequency, it was shown that sound pressure levels by frequency are totally similar except for those of frequency bands between 100Hz and 500Hz. The result of ANOVA test and post-hoc test, it was shown that sections of surface type have a difference. The result of Micro Surfacing was lower 2~5dB(A) than other surface type. CONCLUSIONS : It is found that the noise reduction performance of Micro Surfacing was better than other surface type.

The Study on the Characteristic Sound Intensity and Frequency of Noise Exposure at Occupational Sites (산업장 소음의 강도 및 주파수 특성에 관한 조사연구)

  • Kim, Kwang Jong;Cha, Chul Whan
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.2
    • /
    • pp.181-191
    • /
    • 1991
  • The present study determined the overall noise level and the distribution of sound pressure level over audible frequency range of noise produced at various work sites. Work-related noise greater than 80dBA produced from 98 separate work sites at 37 manufacturing companies and machine shops were analysed for the overall sound level (dBA) and frequency distribution. In addition, to determine the possible hearing loss related to work site noise, a hearing test was also conducted on 1,374 workers in these work sites. The results of the study were as follows ; 1. Of the total 98 work sites, 57 work sites(58.2%) produced noise exceeding threshold limit value (${\geq}90dBA$) set by the Ministry 01 Labor. In terms of different manufacturing industries the proportion of work sites which exceeded 90dBA was the highest for the cut-stone products industry with 6/6 work sites and lowest for the commercial printing industry with 1/13 work sites. 2. The percentage of workers who were exposed to noise greater than 90dBA was 19.8% (1,040 workers) 01 the total 5,261 workers. In terms of different industries, cut-stone products industry had the most workers exposed to noise exceeding 90dBA with 82.8%, textile bleaching and dyeing industry was next at 30.6% followed by fabricated metal products industry with 27.9%, plastic products manufacturing industry had the lowest percentage of workers exposed to 90dBA exceeding noise with 4.5%. 3. There was a statistically significant correlation between the frequency of noise-induced hearing loss and the percentage of workers exposed to noise exceeding 90dBA (P<0.05). 4. The frequency analysis of noise produced at the 98 work sites revealed that 44 work sites (44.9%) had the maximum sound pressure level at high-frequencies greater than 2KHz. In addition, significantly higher sound pressure level was detected at the high-frequencies at 90dBA exceeding work sites as compared to below 90dBA work sites (P<0.01). 5. The differences in sound level meter's A-and C-weighted sound pressure levels were analysed by frequencies. Of the 28 work sites which showed 0-1 dB difference in the two weighted sound levels, 20 work sites (71.4%) had significantly higher sound pressure levels at high-frequencies greater than 2KHz (P<0.01). Furthermore, there was a tendency for higher sound pressure levels to occur in the high-frequency range as the differences in the two weighted sound levels decreased.

  • PDF

Design of Low Noise Axial Flow Fan Using Specific Sound Presssure Level (비소음 측정을 이용한 저소음 축류홴 설계)

  • 김창준;이동익
    • Journal of KSNVE
    • /
    • v.10 no.5
    • /
    • pp.873-879
    • /
    • 2000
  • Experimental investigation was conducted to study the effects of pitch angle maximum camber on the performance and noise of an axial-flow fan used in outdoor-unit of air -conditioner. For this study the axial-flow fan whose pitch angle can be varied was made and the Specific sound Pressure Level and other coefficients were measured using the anechoic fan tester. It is found that pitch angle affects more severly than the maximum camber on the fan performance. On the while the maximum camber affects much on the specific sound power level. Present results show that it is important to choose the optimum pitch angle and maximum camber to design the high-performance and low-noise axial-flow fan and specific noise measured in the anechoic fan tester can be sued effectively for the design of low-noise fan.

  • PDF

A Study on Development of the Prediction Model Related to the Sound Pressure in Terms of Frequencies, Using the Pass-by and NCPX Method (Pass-by계측과 NCPX계측에 의한 주파수 별 음압 예측 모델 개발에 관한 연구)

  • Kim, Do Wan;Mun, Sungho;An, Deok Soon;Son, Hyeon Jang
    • International Journal of Highway Engineering
    • /
    • v.15 no.6
    • /
    • pp.79-91
    • /
    • 2013
  • PURPOSES : The methods of measuring the sound from the noise source are Pass-by method and NCPX (Noble Close Proximity) method. These measuring methods were used to determine the linkage of TAPL (Total Acoustic Pressure Level) and SPL (Sound Pressure Level) in terms of frequencies. METHODS : The frequency analysis methods are DFT (Discrete Fourier Transform) and FFT (Fast Fourier Transform), CPB (Constant Percentage Bandwidth). The CPB analysis was used in this study, based on the 1/3 octave band option configured for the frequency analysis. Furthermore, the regression analysis was used at the condition related to the sound attenuation effect. The MPE (Mean Percentage Error) and RMSE (Root Mean Squared Error) were utilized for calculating the error. RESULTS : From the results of the CPB frequency analysis, the predicted SPL along the frequency has 99.1% maximum precision with the measured SPL, resulting in roughly 1 dB(A) error. The TAPL results have precision by 99.37% with the measured TAPL. The predicted TAPL results at this study by using the SPL prediction model along the frequency have the maximum precision of 98.37% with the vehicle velocity. CONCLUSIONS : The Predicted SPL model along the frequency and the TAPL result by using the predicted SPL model have a high level of accuracy through this study. But the vehicle velocity-TAPL prediction model from the previous study by using the log regression analysis cannot be consistent with the TAPL result by using the predicted SPL model.

Allowable sound pressure levels of ceiling mounted air-conditioning sounds (천장형 에어컨 소음의 허용 음압레벨 도출)

  • You, Jin;Jeong, Choong-Il;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.689-692
    • /
    • 2008
  • Noises from ceiling mounted air-conditioning units were recorded in various actual situations such as offices, classrooms and libraries. Eight specimens of air-conditioners from major domestic and foreign manufacturers' were investigated in this study. A head and torso simulator was located 1.5 m beneath the air-conditioner panel for the measurements and sound pressure levels of the recording sounds were varied from 28 to 55 dBA with 3 dB steps for subjective evaluations. A total of 88 stimuli was randomly presented to subjects using a headphone system in semi-anechoic chamber. Two-categorized (noisiness and amenity) nine-point scale was used as evaluation method. The third scale ('point 3') among the nine-point scale was set as the threshold of allowable level of the air-conditioning sounds in consideration of the real situations. The results indicate that the allowable sound pressure level is around 34 dBA for both noisiness and amenity categories.

  • PDF

High Performance Piezoelectric Microspeakers and Thin Speaker Array System

  • Kim, Hye-Jin;Koo, Kun-Mo;Lee, Sung-Q;Park, Kang-Ho;Kim, Jong-Dae
    • ETRI Journal
    • /
    • v.31 no.6
    • /
    • pp.680-687
    • /
    • 2009
  • This paper reports on an improved piezoelectric microspeaker with a high sound pressure level of 90 dB, a total harmonic distortion of less than 15%, and coherence higher than 0.9. The fabricated Pb(Zr,Ti)$O_3$ (PZT) microspeakers have a thickness of only 1 mm including the speaker frame and an active area of 18 mm${\times}$20 mm. To achieve higher sound pressure and lower distortion, the PZT piezoelectric microspeaker has a well-designed speaker frame and a piezoelectric diaphragm consisting of a tilted PZT membrane and silicone buffer layer. From the simulation and measurement results, we confirmed that the silicon buffer layer can lower the first resonant frequency, which enhances the microspeaker's sound pressure at a low frequency range and can also reduce useless distortion generated by the harmonics. The fabricated PZT piezoelectric microspeakers are implemented on a multichannel speaker array system for personal acoustical space generation. The output sound pressure at a 30 cm distance away from the center of the speaker line array is 15 dB higher than the sound pressure at the neighboring region 30 degrees from the vertical axis.