• Title/Summary/Keyword: tube current

Search Result 908, Processing Time 0.032 seconds

The Study of Corrosion of Heat Exchanger Tube for Absorption Refrigeration Machine (흡수식냉동기용 열교환기 세관의 부식에 관한 연구)

  • 임우조;정기철;윤병두
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.147-152
    • /
    • 2002
  • This paper was studied on corrosion of heat exchanger tube for absorption refrigeration machine. In the 62 % lithium bromide solution at $60^{\circ}C$, polarization test of Cu, Al-brass, 10 % cupro nickel(90-10 % Cu-Ni) and 30 % cupronickel(70-30 % Cu-Ni) tube was carried out. And polarization behavior, polarization resistance characteristics, open circuit potential, anodic polarization of heat exchanger tube for absorption refrigeration machine were considered. The main results are as following: The open circuit potential of Al-brass tube becomes less noble than that of Cu tube, corrosion current density of that becomes lower than Cu tube. The open circuit potential of cupronickel tube is more noble than that of Cu tube, corrosion current density of that is controlled than Cu tube. The passivation critical current of 30 % Cu-Ni tube is lower than that of 10 % Cu-Ni tube, potential of passive region of that is more wide than 10 % Cu-Ni tube.

  • PDF

Analysis of the Magnetic Effect on the Tube Infrastructure for a Super Speed Tube Train

  • Lee, Hyung-Woo;Cho, Su-Yeon;Cho, Woo-Yeon;Lee, Ju;Kwon, Hyeok-Bin
    • International Journal of Railway
    • /
    • v.2 no.4
    • /
    • pp.170-174
    • /
    • 2009
  • Super speed tube train is introduced to increase the speed of ground transportation. The super speed tube train levitates magnetically and runs in a partial vacuum tube, which can reduce the air resistance significantly. However, the strong magnetic force enough to propel the massive train can affect to the tube infrastructure. In this paper, authors have analyzed the leakage flux patterns and induced eddy current on the tube by using 3-dimensional Finite Element Method. These effects are investigated, especially by varying the materials and diameters of the tube. From the simulation results, the aluminum tube with the diameter of 3[m] is needed to be concerned because the induced eddy current produces joule heat, raises the inside temperature of the tube, and might be able to lead to electro-chemical corrosion on the tube, consequently reduce the durability.

  • PDF

Feasibility of Using the Clamp Meter in Measuring X-Ray Tube Current

  • Kim, Sung-Chul
    • International Journal of Contents
    • /
    • v.9 no.1
    • /
    • pp.38-41
    • /
    • 2013
  • The clamp meter maintains electric safety as a non-invasive method while measuring the absolute value of tube current with it has been recently developed for an X-ray high-tension cable. Especially this can show high accuracy at short X-ray exposure time. Considering such a condition, this study is to evaluate the feasibility of a clamp meter in measuring X-ray tube current by taking the measurements and comparing with those of the Dynalyzer III which has been considered as a standard measuring device. From measuring the tube current accuracy depending on changes in tube voltage and exposure time, the clamp meter showed higher accuracy rate which was -1.3~4.2% difference. Thus clamp meter can be used for clinical radiologists who are not familiar electric circuit to manage X-ray devices easily and correctly in the future.

Image Evaluation according to Tube Current of X-ray Device for Intraoral Imaging (구내 촬영용 엑스선 장치의 관전류에 따른 영상 평가)

  • A Yeon Kim;Byungdu Jo;Seung-Jae Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.515-521
    • /
    • 2023
  • The radiation dose received by the patient varies according to the tube current and time used during dental intraoral imaging. A large amount of tube current is required for image quality, but the radiation dose to the patient increases accordingly. Therefore, in this study, the optimal amount of tube current that can reduce the radiation dose received by the patient while securing the image quality was calculated through the evaluation of the image quality according to the tube current used during intraoral imaging through simulation. The average tube current, time, and tube voltage presented in the Guidelines for Diagnostic Reference Level for intraoral radiography were used as basic imaging conditions, and images were obtained when only the tube current was changed, and then the optimal tube current was compared and analyzed with the basic image quantity was calculated. Images were obtained by changing the tube current to 0.1, 0.5, 1, 2, 3, 4 and 5 mA under the basic conditions of 63 kV, 6 mA, and 0.29 s. The obtained image was evaluated for structural similarity index with the image taken under the condition of 6 mA using the ICY program. As a result, even under the condition of 0.5 mA tube current, the index of structural similarity with the image of 6 mA was evaluated to be high. Based on these results, it is considered that the radiation dose given to the patient can be greatly reduced if imaging is performed at 0.5 mA instead of 6 mA during dental intraoral imaging.

Comparison of Noise and Doses of Low Dose and High Resolution Chest CT for Automatic Tube Current Modulation and Fixed Tube Current Technique using Glass Dosimetry (유리선량계를 이용한 관전류자동조절기법과 고정관전류기법에서 저선량 및 고해상 흉부CT의 노이즈 및 선량 비교)

  • Park, Tae Seok;Han, Jun Hee;Jo, Seung Yeon;Lee, Eun Lim;Jo, Kyu Won;Kweon, Dae Cheol
    • Journal of Radiation Industry
    • /
    • v.11 no.3
    • /
    • pp.131-137
    • /
    • 2017
  • To compare the radiation dose and image noise of low dose computed tomography (CT) and high resolution CT using the fixed tube current technique and automatic tube current modulation (CARE Dose 4D). Chest CT and human anthropomorphic phantom were used the RPL (radiophotoluminescence) dosimeters. For image evaluation, standard deviation of mean CT attenuation coefficient and CT attenuation coefficient was measured using ROI analysis function. The effective dose was calculated using CTDIvol and DLP. CARE Dose 4D was reduced by 74.7% and HRCT by 64.4% compared to the fixed tube current technique in low dose CT of chest phantom. In CTDIvol and DLP, the dose of CARE Dose 4D was reduced by fixed tube current technique. For effective dose, CARE Dose 4D was reduced by 47% and HRCT by 46.9% compared to the fixed tube current method, and the dose of CARE Dose 4D was significantly different (p<.05). Noise in the image was higher than that in the fixed tube current technique. Noise difference in the image of CARE Dose 4D in low dose CT was significant (p<.05). The low radiation dose and the noise difference of the CARE Dose 4D were compared with the fixed tube current technique in low dose CT and HRCT using chest phantom. The radiation doses using CARE Dose 4D were in accordance with the national and international dose standards. CARE Dose 4D should be applied to low dose CT and HRCT for clinical examination.

Study on Generator Control for a Small X-Ray Tube (X-선 튜브의 고전압 발생장치 제어에 관한 연구)

  • Lee, Soonhyouk;Ji, Yun-Seo;Choi, Sang Gyu;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.248-254
    • /
    • 2014
  • The purpose of this study is to develope a control system for a small X-ray tube generator and investigate control methods for the X-ray generator. The small X-ray tube was developed for electronic brachytherapy, and thus, the new control method should be investigated, if the small X-ray tube is used for the imaging system. The Axxent S700 X-ray tube and the XF060NZZ485 high voltage generator were used to compose a X-ray imaging system and control board was developed by using AT90CAN128 MCU. The two control methods were investigated after tube voltage was set to 50 kV, one was filament current control method and the other was beam current control method. The former was subdivided into two methods according to the filament heating time, the 5 and the 10 seconds respectively. In the filament current method, the beam current did not rise up to the desired value, if the filament current had not been maintained for at least 10 seconds. The onset filament currents to generate beam current were varied from 1,300 to 1,350 mA and over 5 seconds were needed in order to reach the desired tube current value after beam current was generated. However, in the tube current control method, the beam current reached to the desired value without any time delay with the filament current of 1,500 mA. In this study, we found that the beam current control method was appropriate for the use of small X-ray tube developed for brachytherapy in the X-ray imaging system.

Comparison Radiation Dose of Z-Axis Automatic Tube Current Modulation Technique with Fixed Tube Current Multi-Detector Row CT Scanning of Lower Extremity Venography (하지 정맥조영술 MDCT에서 고정 관전류 기법과 Z-축 자동 관전류 변동 제어에 의한 선량 비교)

  • Yoo, Beong-Gyu;Lee, Jong-Seok;Jang, Keun-Jo;Jeon, Sang-Hwan;Kim, Yong-Soo;Kweon, Dae-Cheol
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.3
    • /
    • pp.123-133
    • /
    • 2007
  • Z-axis automatic tube current modulation technique automatically adjusts tube current based on size of body region scanned. The purpose of the current study was to compare noise, and radiation dose of multi-detector row CT (MDCT) of lower extremity performed with Z-axis modulation technique of automatic tube current modulation with manual selection fixed tube current. Fifty consecutive underwent MDCT venography of lower extremity with use of a MDCT scanner fixed tube current and Z-axis automatic tube current modulation technique (10, 11 and 12 HU noise index, $70{\sim}450\;mA$). Scanning parameters included 120 kVp, 0.5 second gantry rotation time, 1.35:1 beam pitch, and 1 mm reconstructed section thickness. For each subject, images obtained with Z-axis modulation were compared with previous images obtained with fixed tube current (200, 250, 300 mA) and with other parameters identical. Images were compared for noise at five levels: iliac, femoral, popliteal, tibial, and peroneal vein of lower extremity. Tube current and gantry rotation time used for acquisitions at these levels were recorded. All CT examinations of study and control groups were diagnostically acceptable, though objective noise was significantly more with Z-axis automatic tube current modulation. Compared with fixed tube current, 2-axis modulation resulted in reduction of CTDIvol (range, $-6.5%{\sim}-35.6%$) and DLP (range, $-0.2%{\sim}-20.2%$). Compared with manually selected fixed tube current, 2-axis automatic tube current modulation resulted in reduced radiation dose at MDCT of lower extremity venography.

A Study of Eddy Current Test for fin Tube in Different Fin Height (Fin 높이가 다른 Fin Tube의 와전류탐상에 관한 연구)

  • 이동진
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.118-124
    • /
    • 2003
  • 응축기, 증발기, 전열관에 사용되는 Fin Tube는 열전달효율 향상을 위하여 Fin의 높이 를 증가시키고, Tube의 최소두께를 얇게 가공하는 경향으로 발전하고 있다. 따라서, Fin Tube의 와전류탐상(ECT; Eddy Current Testing)에 의한 결함검출에 더욱 어려움이 예상된다. 본 연구에서는 Fin Tube의 Fin 높이를 3단계로 변화시켜 Tube를 제작하고, Tube에 축 방향결함, 원주방향결함, 원형결함을 각각 Fin Tube의 안쪽에 최소두께의 20%, 40%, 60% 의 동일결함율을 갖는 인공결함 시험편을 제작하였다. 제작한 원형결함시험편에 와전류탐상을 수행하여 Fin 높이에 따른 최적주파수의 변화를 연구하였다. Fin높이가 다른 원형결함 시험편에 1~20KHz 주파수를 적용한 결과 최적주파수는 12KHz로 Fin높이에 크게 영향을 받지 않음을 밝혔다 또한 Fin높이에 따른 최적주파수변화는 크지 않으나 Fin 높이가 높을수록 100%관통결함의 위상각(40')에 근접하여 나타났다. 축방향결함, 원주방향결함, 원형결함을 갖는 시험편에 와전류탐상을 수행한 결과 원형결함을 갖는 시험편의 신호 감도가 축방향결함, 원주방향결함보다 좋게 나타났다.

  • PDF

The Study on Corrosion Characteristics of Heat Exchanger Tube for Gas Absorption Refrigeration & Hot Water System (가스흡수식 냉온수기 열교환기용 세관의 부식특성에 관한 연구)

  • Jeong Ki Cheol
    • Journal of the Korean Institute of Gas
    • /
    • v.6 no.1 s.17
    • /
    • pp.92-97
    • /
    • 2002
  • This paper was studied on corrosion characteristics of gas absorption refrigeration & hot water system using $LiBr-H_2O$ working fluids. In the $62\%$ lithium bromide solution at $60^{\circ}C$, polarization test of Cu, $10\%$ cupronickel($90-10\%$ Cu-Ni) and $30\%$ cupronickel($70-30\%$ Cu-Ni) tube was carried out. And polarization behavior, polarization resistance characteristics, open circuit potential, anodic polarization of heat exchanger tube for gas absorption refrigeration & hot water system were considered. The main results are as following: 1) Polarization resistance of heat exchange tubes appears high in order of $30\%$ cupronickel tube > $10\%$ cupronickel tube > Cu tube. B) Open circuit potential of cupronickel tube is more noble than that of Cu tube, and corrosion current density of cupronickel is controlled than Cu tube. 3) Potential of passive region of $30\%$ cupronickel tube is more wide than that of $10\%$ cupronickel tube, and the passivation critical current of $30\%$ cupronickel tube is lower than that of $10\%$ cupronickel tube.

  • PDF

A Study on Conductivity Characteristics of the Insulating Oil for X-ray Tube Housing (X선장치용(線裝置用) 절연유(絶緣油)의 도전특성(導電特性)에 관한 연구(硏究))

  • Kim, Young-Il;Lee, Duck-Chool;Chung, Yon-Tack
    • Journal of radiological science and technology
    • /
    • v.9 no.1
    • /
    • pp.73-81
    • /
    • 1986
  • This paper carried out an experiment on the characteristics of time, temperature, electric field and the dependense of electrode materials and gap length by the conduction current of the insulating oil used for x-ray tube housing. The obtained results can be summarized as following: 1. In the x-ray tube housing insulating oil with vacuum condition, conduction current is declined more than the x-ray tube housing insultaing oil with the air, and is held stable states. 2. At the low electric field the higher temperature of the x-ray tube housing insulating oil is increased, the more conduction current. 3. The dependence of electrode material is appeared at the low electric field and the short gap length than the high and the long with Fe> Cu >Al. 4. At the I-E characteristics, the low electric field than 1000 [V/cm] is appeared Ohm's law region, and the high become saturation region. 5. At the same electric field, the longer gap length become, the more conduction current is increased, and the same applied voltage, the longer, the less conduction current is decreased, the less low than high temperature x-ray tube housing insulating oil.

  • PDF