• Title/Summary/Keyword: type III

Search Result 2,378, Processing Time 0.035 seconds

ORDER RESTRICTED TESTS FOR SYMMETRY AGAINST POSITIVE BIASEDNESS

  • Oh, Myong-Sik
    • Journal of the Korean Statistical Society
    • /
    • v.36 no.3
    • /
    • pp.335-347
    • /
    • 2007
  • Two new types of positive biasedness, which are closely related to Type III positive biasedness (Yanagimoto and Sibuya, 1972), are proposed. We call these near Type III positive biasedness. Though no implication between Type II and near Type III biasedness exists, near Type III seems to be less restrictive than Type II biasedness. Constrained maximum likelihood estimates of distribution functions under near Type III positive bisedness are obtained. The likelihood ratio tests of symmetry against new positive biasedness restrictions are proposed. A small simulation study is conducted to compare the performance of the tests.

Analysis of Clinocopathologic Difference between Type II and Type III Cancers in Siewert Classification for Adenocarcinomas of the Cardia (Siewert 분류에 의한 협의의 분문부 위암(type II)과 분문하 위암(type III)의 검토)

  • Kim Hyoung-Ju;Kwon Sung Joon
    • Journal of Gastric Cancer
    • /
    • v.4 no.3
    • /
    • pp.143-148
    • /
    • 2004
  • Purpose: To determine the clinical value of the Siewert classification for gastic-cancer patients in Korea, we evaluated and compared the clinicopathologic factors of type II and type III cancer. Materials and Methods: The medical records of 89 consecutive patients who had undergone surgery for an adenocarcinoma of the gastroesophageal junction (GEJ) at the Department of Surgery, Hanyang University Hospital, between Jun. 1992 and Dec. 2003 were reviewed retrospectively. Results: There were one patient with type I, 12 pateints with type II and 77 patients with type III. During the same period, 1,341 patients underwent surgery for a gastric carcinoma, so proportion of GEJ cancer being $6.6\%$. The median followup duration was 31 months (range: $2\∼135$ months), and the follow-up rate was $100\%$. Between type II and type III cancers, there were no significant differences in the clinicopathologic variables including age, sex, gross appearance, histologic type, depth of invasion, and pathologic stage. The longest diameter of the tumor was larger in type III ($6.1\pm2.1$ cm) than in type II ($3.9\pm1.1$ cm)(P=0.001). A total gastrectomy with Roux-en-Y esophagojejunostomy was done most frequently, while jejunal interposition was done in 3 cases of type II and 2 cases of type III. More than a D2 lymphadenectomy was done all cases. The numbers of dissected lymph nodes and metastatic lymph nodes in type II were 43.8 and 5.8 respectively, while they were 49.8 and 8.1 in type III, but the difference between the two groups were not statistically significant. The mean length of the proximal resection margin was $15\pm5$ mm in type II and $21\pm13$ mm in type III, but this difference was not statistically significanct. The time to recurrence after operation was 19.3 months in type II and 16.9 months in type III. The five-year survival rates of type II and III were $68.8\%\;and\;52.7\%$ respectively, but difference was not significant. Conclusion: There were no significant differences in the clinicopathologic variables, including survival rate, between type II and type III cancers in Korean patients According to these findings, it appears to be reasonable to classify type III cancer as a cardia cancer in a broad sense.

  • PDF

Identification of Secretion Signals of Target Proteins in Salmonella enterica serovar Typhimurium and Construction of Secretion Vector using this Signal (Salmonella enterica serovar Typhimurium에서 Type III 분비장치의 표적단백질들의 분비신호 확인 및 Type III 분비장치를 이용한 Secretion Vector의 개발)

  • Choi, Hyuk-Jin;Eom, Joon-Ho;Cho, Jung-Ah;Lee, Sun;Lee, Kyoung-Mi;Lee, In-Soo;Park, Yong-Keun
    • Korean Journal of Microbiology
    • /
    • v.36 no.4
    • /
    • pp.254-258
    • /
    • 2000
  • Invasion process of bacterial cell into intestinal epithelium is important in Salmonella infection. The invasion is induced by the proteins secreted by type III secretion appratus of Salmonella. It has been known that the proteins do not have N-terminal signal peptide existing in general secreted proteins. Recent studies on Yersinia reported that secretion signal of type III appratus may lie on 5'end secondary structure of mRNA of secreted protein. In this study, we constructed translational fusion of ompR and sopE, encoding type III secretion protein of Salmonella, and observed secretion of the fusion protein for investigating the secretion signal of Salmonella type III appratus. The sopE DNA fragments of the translational fusion contain the region of promoter and from start code to tenth or to fifth code. These translational fusions indicate that type III secretion signal of Salmonella is located on 5'end of mRNA encoding secreted protein. We constructed prototype of secretion vector using this signal to produce useful foreign protein.

  • PDF

A study on the Stability of Discrete-time Affine Type III Fuzzy Control System (이산 시간 어핀 Type III 퍼지 제어 시스템의 안정도에 대한 연구)

  • Kim, Eun-Tai;Lee, Hee-Jin
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.38 no.4
    • /
    • pp.1-10
    • /
    • 2001
  • In this paper, we propose the stability analysis and design methodology for the discrete-time affine Type III fuzzy system via the convex optimization technique. First, the stability condition is derived under which the discrete-time affine Type III fuzzy system is quadratically stable in the large. Next, the derived condition is reformulated into the convex optimization problem called Linear Matrix Inequalities (LMI) and numerically addressed. Finally, the effectiveness and the feasibility of the proposed analysis and design methodology is highlighted via an example and its computer simulation result.

  • PDF

Strength Properties of Wooden Model Retaining Wall Using Preservative Treated Square Timber of Domestic Pinus rigida Miller (리기다소나무 방부 정각재를 이용한 목재 옹벽의 강도 성능 평가)

  • Park, Jun-Chul;Kim, Keon-Ho;Lee, Dong-Heub;Hwang, Won-Joung;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.38 no.6
    • /
    • pp.532-540
    • /
    • 2010
  • The strength properties of wooden model retaining wall made of pitch pine (Pinus rigida Miller) was evaluated. Three different types of wooden model retaining wall were made of the 11cm square timber treated with CUAZ-2 (Copper Azole). The retaining wall was made into the 4 layers of crossbar and the 3 layers of vertical-bar, of which the size was 86 cm high, 200 cm long and 96 cm wide. Type I was control and in Type II 20 cm vertical-bars and 93 cm vertical-bars were arranged alternately to decrease wood usage. TypeIII was similar to TypeII except that the connection between crossbars was reinforced with the wooden armature. In each type, the strength properties of retaining wall were investigated by horizontal loading test and the deformation of structure by image processing (AICON 3D DPA-PRO system). In horizontal loading test of Type I, Type II and Type III was 63.17, 57.80, and 60.97 kN/m, respectively. The deformation of the top layer in Type II was 1.5 times larger than in Type I and Type III. Consequently, the economic efficiency and strength performance were better in Type III than in Type I and Type II.

Extended Indications of Bilhaut-Cloquet Procedure for Type III and IV of Duplicated Thumb (무지 다지증 III, IV형의 치료에 Bilhaut-Cloquet 방법의 적극적 이용)

  • Lim, Young-Bin;Seul, Jung-Hyun;Nam, Hyun-Jae;Woo, Sang-Hyun
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.821-828
    • /
    • 2011
  • Purpose: The authors applied Bilhaut-Cloquet procedure to Wassel type III and IV duplicated thumb, which was limited to patients with Wassel type I, II. This procedure was applied in order to improve the growth potential, range of joint motion, joint stability and cosmetic outcome. Methods: Sixteen patients received Bilhaut-Cloquet procedures to correct duplicated thumbs from May, 2005 to December, 2010. Seven patients were Wassel type III, nine patients were type IV. This procedure was applied not only to balanced type, but also unbalanced type or convergent type. Five patients were balanced type and eleven patients were unbalanced type. Convergent type of Wassel type IV was three. Sex ratio was the same, mean age at the operation was 20.1 months old (8~52 months old). Angular deformity, joint stability and range of joint motion and cosmetic outcome were considered together and estimated in Tada score. Also, postoperative subjective satisfaction score of the parents was evaluated by a 100-points scale. Results: Mean subjective satisfaction scored 75 points at 28 months after the operation. Radiologic study showed bony union of proximal phalangeal bone and stable joint in all patients. Range of motion was mean 20 degrees in interphalangeal joint and mean 73 degrees in metacarpophalangeal joint. Tada score showed 'good' in eleven patients (68.8%), 'fair' in three patients (18.7%) and 'poor' in two patients (12.5%). In seven patients those who were able to follow up for a long term showed no significant difference in length of proximal and distal phalangeal bones compared to the opposite thumb. Conclusion: Bilhaut-Cloquet procedure can be applied not only to balanced type of Wassel type III, IV duplicated thumb, but also to unbalanced type or convergent type that focused on functional reconstruction and cosmetic improvement.

A COMPARATIVE STUDY OF BOND STRENGTH OF RECYCLED BRACKETS (재생 브라켓의 전단접착강도에 관한 비교 연구)

  • Shur, Cheong-Hoon;Choi, Eun-Ah
    • The korean journal of orthodontics
    • /
    • v.28 no.4 s.69
    • /
    • pp.641-657
    • /
    • 1998
  • This study was undertaken to compare the bond strength and the fracture site of new and recycled brackets according to the base design. 252 sound premolars extracted for orthodontic treatment were collected and Type I, Type II, Type III brackets were divided into four groups by recycling method Each bracket was then bonded to an extracted premolar. Instron Universal Testing Machine(model W) was used to measure the shear bond strength, and the surface of the recycled brackets were viewed in SEM For the analysis of the results, one way ANOVA and Scheffe's multiple range test was executed using the SPSSWIN program. 1. The shear bond strength showed statistically significant difference according to the bracket base design(p<0.001). Type III bracket(round indentation base, micro-etched) showed the highest bond strength, Type I bracket(foil-mesh base) was second, and Type II bracket(grooved integral base, micro-etched) was last. 2. The effect of recycling on the bond strength was different according to bracket type. The shear bond strength of Type I, Type II brackets showed the smallist reduction when treated for 1 minute in Big Jane(p<0.05), but the shear bond strength of Type III brackets showed no statistically significant difference according to recycling method(p>0.05). 3. In Type I, Type II brackets, frequent fracture site was bracket-resin interface, but in Type III brackets, about half of the resin was retained on the tooth surface frequently. 4. The shear bond strength was highest when about half of the resin was retained on the tooth surface(p<0.05). 5. The resin remnant on the bracket base after recycling had no effect on the shear bond strength.

  • PDF

Conservative Endodontic Treatment of Type III Dens Invaginatus : Case Report (Type III 치내치의 보존적 근관치료 : 증례보고)

  • Jo, Wansun;Lee, Nanyoung;Lee, Sangho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.41 no.2
    • /
    • pp.174-179
    • /
    • 2014
  • Dens invaginatus is a developmental anomaly resulting from an infolding of the enamel organ into the dental papilla prior to calcification of the dental tissue. Clinical and radiographic presentation of dens invaginatus shows a lot of variation. The classification proposed by Oehlers(1957) is most commonly used among classifications of dens invaginatus. Several treatments have been suggested to treat Type III dens invaginatus where the pulp remains healthy but the invagination is associated with a periodontitis. The top priority objective is to preserve pulp as sound as possible. Thus, if there is no definite evidence of pulpal disease, the conservative access which treat invagination as distinct from the pulp is necessary. But, Endodontic treatment of Type III dens invaginatus has the particular problems associated with achieving adequate chemomechanical debridement of the root canal system and invagination, predictable length control and consistent filling. In this case report, the endodontic treatment limited within invagination was performed for treatment of Type III dens invaginatus, and filling with Mineral Trioxide Aggregate(MTA) resulted in good prognosis.

Clinical Experience of Tricuspid Atresia Type III (삼첨판 폐쇄 type III 수술치험 4례)

  • 함시영
    • Journal of Chest Surgery
    • /
    • v.20 no.4
    • /
    • pp.751-759
    • /
    • 1987
  • We have experienced 4 cases of modified Fontan operation for Tricuspid atresia type III from February 1983 to May 1987 at the department of Thoracic 8 Cardiovascular Surgery, Seoul National University Hospital. There were 3 cases with left juxtaposition of right atrial auricle. The operatic mortality rate was 25% [one case death].

  • PDF

An Analysis of the Definition and the Meaning Used for the Terms of Heat and Thermal Energy in the Science Textbooks (과학과 교과서에 나타난 열과 열에너지 용어의 정의 및 사용 의미 분석)

  • Kim, Serim;Park, Jong-Yoon
    • Journal of the Korean Chemical Society
    • /
    • v.62 no.3
    • /
    • pp.214-225
    • /
    • 2018
  • In this study, we tried to find out how heat and thermal energy terms are defined and used in Korean science textbooks, and to see if there are any differences in the meaning of these terms used in different areas of science. For this purpose, the contents of 52 science textbooks of elementary, middle and high school published by the 2009 revised curriculum were analyzed. The definition of the term heat is given in the middle school Science(1) and the high school Physics I and II textbooks. Most textbooks define heat as "energy transferred due to a temperature difference (Type I)". Only one textbook of Physics I defines heat as "transfer of energy due to a temperature difference (Type II)". The definition of thermal energy is mostly presented in the middle school Science (2) and the high school Physics I textbooks. Physics I textbooks define the thermal energy as "molecular kinetic energy (Type III)", while Science(2) textbooks define it as Type I or "energy causes temperature change or phase transition of matter (Type IV)". In the texts of textbooks, heat is mainly used as the meaning of Type I or Type III. Thermal energy is mainly used as Type III, but it is also used as Type I in the high school Physics and Chemistry textbooks. The meanings of heat and thermal energy terms used are differed by the area of science. They are mainly used as type I or type III in Physics and Chemistry textbooks, and used as type III in Life Science and Earth Science textbooks.