• 제목/요약/키워드: ultrasound

검색결과 3,000건 처리시간 0.034초

Effect of ultrasound treatment on the quality properties of chicken breast meat and the broth from Korean chicken soup (Baeksuk)

  • Jung, Samooel;Jo, Kyung;Lee, Sunmin;Choi, Yun-Sang
    • 농업과학연구
    • /
    • 제46권3호
    • /
    • pp.539-548
    • /
    • 2019
  • This study investigated the influence of ultrasound treatment on the quality properties of chicken breast meat and the broth from Korean chicken soup (Baeksuk). In this study, the internal temperature, malondialdehyde content, textural profile, color, dry matter, protein content, phenolic content and sensory properties of chicken breast meat broth from chicken soup with ultrasound treatment were analyzed. The chicken, plants, salt, and water were vacuum packaged in a retort pouch. The chicken soup was manufactured with ultrasound treatment (45 kHz and $1.6W\;cm^{-2}$) in a water bath at $85^{\circ}C$. The texture properties, color, and lipid oxidation of the chicken breast meat from the chicken soup were not affected by the ultrasound treatment. There was no significant difference in the lipid oxidation in the broth of the chicken soup between the control and ultrasound treatment. The dry matter and crude protein contents of the broth were significantly increased by the ultrasound treatment. The broth flavor of the chicken soup manufactured with the ultrasound treatment received a higher score than that of the control in the sensory analysis. There were no differences in the sensory properties of the chicken breast meat from the chicken soup between the control and ultrasound treatment Therefore, the broth quality of the chicken soup can be improved by heating with ultrasound treatment. Additionally, to apply ultrasound technology to the production chicken breast meat and the broth from chicken soup, it is necessary to further study the quality characteristics of the breast meat and broth according to various frequencies and strengths.

운동 전 적용된 지속초음파와 맥동초음파가 운동 유발성 근육 손상의 최대등척성근력과 관절가동범위에 미치는 효과 (The effects of pulsed ultrasound and continued ultrasound intervention before an exercise on maximal voluntary isometric contraction and range of motion of exercise-induced muscle damage)

  • 김하늘;전재근;신성필
    • 대한물리치료과학회지
    • /
    • 제28권2호
    • /
    • pp.19-29
    • /
    • 2021
  • Background: The purpose of this study was to investigate the effects of pulsed-ultrasound intervention and continued-ultrasound on the MVIC (maximal voluntary isometric contraction) and active ROM (range of motion) recovery of before EIMD (exercise-induced muscle damage). Design: Randomized controlled trial. Methods: Thirty subjects who are student in their 20s at a university participated in this study, these subjects were assigned into three groups, a control group (n=10), experiment group I (n=10) and experiment group II (n=10). The subjects in experimental group were intervened by pulsed-ultrasound and continued-ultrasound, while ones on control group weren't by any intervention after induced EIMD. Results: First, In comparison of the MVIC, in the among group comparison, the MVIC of continued-ultrasound group was significantly larger than those of other groups (p<.005). Second, In the among group comparison, the active extension angle of continued-ultrasound group was significantly smaller than those of other groups (p<.005). Third, In the among group comparison, the active flexion angle of continued-ultrasound group was significantly lager than those of other groups (p<.05). Conclusion: The above results revealed that the continued-ultrasound intervention before an exercise had a significantly improve of muscle function after EIMD. Therefore we can consider the continued ultrasound as a considerable intervention method to prevent or reduce an exercise injury.

한방부인과 임상실습교육에서 초음파 팬텀의 활용과 효과 (The Use and Educational Effect of Ultrasonic Phantom in Korean Medicine Obstetrics and Gynecology Clinical Practice Education)

  • 양승정;조성희
    • 대한한방부인과학회지
    • /
    • 제35권2호
    • /
    • pp.16-27
    • /
    • 2022
  • Objectives: The purpose of this study is to analyze educational effect of ultrasound examination training with ultrasonic phantom in the department of Korean Medicine Obstetrics and Gynecology. Methods: All 4th grade students in 2021 and 2022 of school of Korean Medicine, Dong-Shin University must be trained in the department of Korean Medicine Obstetrics and Gynecology according to ultrasound examination training guideline including Objective Structured Clinical Examination (OSCE). After completing ultrasound examination training, we distributed questionnaires to them about a confidence before OSCE and after OSCE, difficulty in using ultrasound, ultrasound reading, difficulty with probe manipulation and computer operation, ultrasound understanding, clinical usefulness. And then, we analyzed the related factors including descriptive statistics, frequency analysis, student's t-test and paired t-test by SPSS 12.0. Results: Confidence in using ultrasound showed differences among students by gender and year, but it was not statistically significant. The difficulty of ultrasound use and ultrasound reading was at a moderate level, and the gender difference was not significant, and the difference between the practical students by year was statistically significant. The difficulty of the operation of the ultrasonic probe was at a normal level, and the difference between the students in practice by gender and year was not statistically significant. Although they answered that they had a very good understanding of the use of ultrasound, there was a gender difference and it was statistically significant, and practical students by year was not statistically significant. They answered that the effect on clinical use was very sufficient, but it was not statistically significant. The appropriateness of the practice time was evaluated at a moderate level. Conclusions: The use and educational effect of ultrasound examination using ultrasonic phantom in the department of Korean Medicine Obstetrics and Gynecology clinical practice education was very effective.

초음파에 의한 전완 국소 온도와 정중 운동 신경전도 속도의 변화 (Alteration of Forearm Local Temperature and Median Nerve Conduction Velocity by Therapeutic Ultrasound in Healthy Adult Subjects)

  • 전차선;김택연
    • 대한정형도수물리치료학회지
    • /
    • 제12권1호
    • /
    • pp.37-43
    • /
    • 2006
  • PURPOSE: Previous studies have documented the lack of ultrasound's non-thermal effects on nerve conduction using frequencies of 1 MHz and 870 kHz. The purpose of this study was to determine the biophysical effects of continuous ultrasound on median local forearm temperature and motor nerve conduction velocities using frequencies of 3.0 MHz. SUBJECTS: Twelve healthy subjects (6 males, 6 females, age $22.30{\pm}2.41$ yrs, weight $61.33{\pm}10.16$ kg, height $167.58{\pm}8.04$ cm) without a history of neurological or musculoskeletal injury to their dominant arm volunteered for this study. METHODS AND MATERIALS: Each subject received a total of five treatments, one each at .0, 0.5, 1.0, 1.5, 2.0 W/$cm^2$ of 3 MHz continuous ultrasound on the anterior surface of the middle area of dominant forearm for 10 minutes. Dependent measures for forearm local temperature and median motor nerve conduction velocity (MNCV) were taken pretreatment and immediately post-treatment. One-way ANOVA were used for each dependent measure. RESULTS: The posttreatment forearm local temperature were differed significantly (p<0.001) between intensities of ultrasound. The posttreatment forearm local temperature of the ultrasound treated with 1.0 w/$cm^2$, 1.5 w/$cm^2$ and 2.0 w/$cm^2$ were significantly higher than 0.5 w/$cm^2$ and 0.0 w/$cm^2$ of ultrasound (p<0.05). The posttreatment median MNCV were differed significantly from the respective pretreatment velocities (p<0.001). The MNCV of the ultrasound treated with 0.0 w/$cm^2$ and 0.5 w/$cm^2$ were significantly (p<0.05) slower than that observed pretreatment, while the three ultrasound intensities produced significantly increased posttreatment MNCV: 1.0 w/$cm^2$ and 1.5 w/$cm^2$ and 2.0 W/$cm^2$. The posttreatment MNCV at 2.0 w/$cm^2$ and 1.5 w/$cm^2$ was significantly faster than that at 0 w/$cm^2$, 0.5 w/$cm^2$ and 1.0 w/$cm^2$ (p<0.05), the MNCV at 1.0 w/$cm^2$ was significantly faster than that associated with 0 w/$cm^2$ and 0.5 w/$cm^2$ of ultrasound (p<0.05). CONCLUSIONS: The decreased median motor forearm local temperature and MNCV of the ultrasound treated with 0.0 w/$cm^2$ and 0.5 w/$cm^2$ were attributed to the cooling effect by ultrasound transmission gel. Local forearm temperature and nerve conduction velocity were directly related to the intensity of ultrasound. Alterations in MNCV from ultrasound on healthy nerves appeared to be related to temperature changes induced by thermal effects of ultrasound.

  • PDF

Extracting gall bladders from ultrasound images

  • Kim, Hyoung-Seop;Ishikawa, Seiji;Kato, Kiyoshi;Tsukuda, Masaaki;Matsuoka, Jun-nosuke
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1995년도 Proceedings of the Korea Automation Control Conference, 10th (KACC); Seoul, Korea; 23-25 Oct. 1995
    • /
    • pp.248-251
    • /
    • 1995
  • Nowadays, the internal images of a human body can be easily provided by the ultrasound imaging, the X-ray CT, or the MRI device, among which the ultrasound imaging device has good resolution for soft tissues of a human body compared with the other devices. Furthermore, the use of ultrasound imaging devices will increase in future especially in the obstetrics, territory, since it does not give harm to the human body. Although several techniques have been investigated until now in order to extract organs from ultrasound images, very few of them have achieved satisfactory results because of low contrast and high noise nature of images. This paper proposes a technique for automatic extraction of the gall bladder area from ultrasound images. The proposed technique first extracts a small reliable area of a gall bladder from an ultrasound image employing smoothing, binarization, expanding and shrinking, and labeling, and then expands the area referring to the binarized version of the original image. The technique is examined its performance by real ultrasound images of a gall bladder and satisfactory results are obtained. Some problems to be solved are discussed finally.

  • PDF

Ultrasonography and Ultrasound-guided Interventions of the Shoulder

  • Moon, Sang Ho;Ko, Kwang Pyo;Baek, Seung Il;Lee, Song
    • Clinics in Shoulder and Elbow
    • /
    • 제18권3호
    • /
    • pp.172-193
    • /
    • 2015
  • Nowadays shoulder ultrasound is commonly used in the assessment of shoulder diseases and is as accurate as magnetic resonance imaging in the detection of several pathologies. Operator dependence is the main disadvantage of shoulder ultrasound. After adhering to a strict examination protocol, good knowledge of normal anatomy and pathologic processes and an awareness of common pitfalls, it can be used as a focused examination providing rapid, real-time diagnosis, and treatment by ultrasound-guided interventions in desired clinical situations. Also shoulder ultrasound can help the surgeon decide whether treatment will be surgical or nonsurgical. If arthroscopy is planned, sonographic findings help to counsel patients regarding surgical and functional outcomes. If a nonsurgical approach is indicated, ultrasound can be used to follow patients. This review article presents the examination techniques, the normal sonographic appearances and the main pathologic conditions found in shoulder ultrasound. And also addresses a simplified approach to scanning and ultrasound-guided intervention. Knowledge of optimal techniques, normal anatomy, dynamic maneuvers, and pathologic conditions is essential for optimal performance and interpretation of images.

ICR 마우스의 태아(胎兒)에 대(對)한 방사선(放射線)과 초음파(超音波)의 공동효과(共同效果)에 관한 실험적(實驗的) 검토(檢討) (Combined Effects of Radiation and Ultrasound on Embryonic Development in Mice)

  • 구연화
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제14권2호
    • /
    • pp.37-44
    • /
    • 1991
  • The combined effect of radiation and ultrasound has been studied in mouse embryos. Radiation and/or ultrasound were adminstered to ICR mice on day 8 of gestation. Intrauterine death, gross malformation, and fetal body weight were selected as indicators of effects. Does of whole-body ${\gamma}-irradiation$ were 0.5 to 2.5 Gy and those of ultrasound were $0.5\;W/cm^2$ to $3\;W/cm^2$. Intrautrine mortality increased with increasing radiation dose ; this trend was more remarkable in combination with ultrasound. Gross malformations such as exencephaly and anophthalmia/microphthalmia appeared frequently in the fetuses treated with both radiation and ultrasound. Decreased fetal weight was observed even in mice treated with 1.5 Gy of radiation or $1\;W/cm^2$ of ultrasound. There was a linear relationship between dose and reduction of fetal weight. The fetal weight was sensitive, precise and easy-to-handle indicator for the effects of growth retardation. Intrauterine mortality and frequencies of exencephaly and anophthalmia/microphthalmia were higher than the sum of those induced by radiation and by ultrasound. The results indicatied that the combined action of radiation and ultrasound on intrauterine death and malformations was synergistic.

  • PDF

무릎관절 퇴행성 골관절염 환자에 대한 초음파, 레이저, 초음파-레이저 복합치료의 효과 비교 (Comparison of the Effects of Ultrasound, Laser, Ultrasound-Laser Integration in Patients with Knee Degenerative Osteoarthritis)

  • 전범수;권혁수;정성관;박지환
    • 대한정형도수물리치료학회지
    • /
    • 제18권1호
    • /
    • pp.57-63
    • /
    • 2012
  • Background: The number of old people with degenerative osteoarthritis one of the chronic disease, were constantly increased. Many researchers have made a great effort to verify the effects of ultrasound and laser therapy in degenerative osteoarthritis treatment. This study applied ultrasound-laser integration therapy on knee joint degenerative osteoarthritis and compared its effect with ultrasound and laser. Methods: We assigned 60 patients age 65 to 85 who had been diagnosed as knee joint degenerative osteoarthritis in G nursing home in Daejeon city. Randomization was done in blocks of three, holding twenty people per each group to receive either ultrasound, laser, ultrasound-laser integration therapy. This study carried out the experiment for 6 weeks to from April 17, 2010. We measured variables using visual analog scale (VAS) and pressure threshold meter (PTM) of the effects by before and after exercise. Results: It has been found that VAS was reduced and PTM was increased in all three groups. Compare with the other groups, Ultrasound-laser integration therapy group had lower VAS and higher PTM than ultrasound therapy and laser therapy group. Conclusions: These results lead us to the conclusion that ultrasound-laser integration have influenced the pain reduction of the knee degenerative osteoarthritis.

  • PDF

인체에 적용한 초음파 및 침전극 저주파자극이 콜린에스테라제의 활성에 미치는 영향 (Effect of stimulus in the Acupuncture point with Ultrasound and Electro-acupuncture on human's Cholinesterase activity)

  • 이정숙;김순희
    • 대한물리치료과학회지
    • /
    • 제7권2호
    • /
    • pp.523-531
    • /
    • 2000
  • The purpose of this study was to investigate the Effect of stimulus in the Acupuncture point with Ultrasound and Electro-acupuncture on human's Cholinesterase activity. Pain is physiological symptoms in human body. Pain stimulation transference is according to Acetylcholine that is a matter of nerve stimulation. Cholinesterase analyze the Acetylcholine and Cholin acetylase compose the Acetylcholine. To identify of Cholinesterase activity, this study attempted to Electroacupuncture and Ultrasound for 20 person. Twenty subjects participating in this consisted of A group(difference of Cholinesterase's figure make use of Electroacupuncture with Zi-Shil), B group(difference of Cholinesterase's figure make use of Ultrasound with Zi-shil), C group(difference of Cholinesterase's figure make use of Eltroacupuncture and Ultrasound with Zi-shil). As a result the following conclusion was draun: 1. A group showed significantly decreased of Cholinesterase's figure make used of Electroacupuncture with Zi-Shil(the period is between pre-application and 20minute after application, between pre-application and mean of 20minute-30minute after application). 2. B group showed significantly decreased of Cholinesterase's figure make used of Ultrasound with Zi-Shil(the period is between pre-application and 3minute after application, between 3minute after application and 7minute after application, between preapplication and 7minute after application, between pre application and mean of 3minute-7minute after application). 3. C group not showed significantly decreased of Cholinesterase's figure make used of Elcetroacupuncture and Ultrasound with Zi-Shil(the period is between pre-application, between 20minute-Eletroacupuncture and 3minute-Ultrasound after application, between 30minute-Eletroacupuncture and 7minute-Ultrasound after application). The results of this study showed that decrease of Cholinestese' s figure make used of Elctroacupuncture and Ultrasound Zi-Shil. The result mean stimulation of Elctroacupuncture and Ultrasound decreased Acetylcholin' quantity. And decrease of Acetylcholin' quantity decreased Cholinesterase' figure.

  • PDF

초음파의 매개변수에 따른 Meloxicam Gel의 경피투과 촉진효과 (Skin Permeation Effects of Meloxicam Gel on Ultrasound Parameters by Phonophoresis)

  • 최석주;윤세원;정대인;김영일;정진규;김태열
    • 대한임상전기생리학회지
    • /
    • 제4권1호
    • /
    • pp.49-61
    • /
    • 2006
  • This study conducted the following experiment to examine and compare transdermal permeation effects according to parameters of ultrasound and physiochemical characteristics of meloxicam. Permeation by ultrasound among these experimental drugs was relatively higher and it was involved in COX-2 inhibition unlike other drugs. Recently use of oral agents has been rapidly increased, but it was not generalized to transdermal agent and this study selected meloxicam that transdermal permeation research using ultrasound was not performed and conducted transdermal permeation experiment with skin of hairless mouse and analyzed permeation with HPLC. It made gel first and analyzed permeation depending on frequency and intensity of ultrasound of meloxicam with the same experimental procedures as the above experiment. The results of this study can be summarized as follows. Transdermal permeation by ultrasound frequency was higher in 1.0 MHz and it was higher as intensity increased. In comparison by parameters of ultrasound, there was similar permeation in $1.0\;W/cm^2$ of continuous mode and $3.0\;W/cm^2$ of pulsed mode and it was effective to high intensity for using pulsed mode. It was found that duty cycle of ultrasound affected transdermal permeation in meloxicam gel used in this experiment and transdermal permeation was higher in used ultrasound as phonophoresis than non-ultrasound for anti-inflammatory effects.

  • PDF