• 제목/요약/키워드: ultrasound

검색결과 3,001건 처리시간 0.034초

Development of an Objective Structured Clinical Examination Checklist and a Post-Education Questionnaire for Musculoskeletal Ultrasound Training Focusing on Volar Wrist and Carpal Tunnel Syndrome

  • Cho, Eunbyul;Han, Young-Min;Kang, Yeonseok;Kim, Jae-Hyo;Shin, Min-Seop;Oh, Myungjin;Jung, Hyun-Jong;Jeon, Hyesoo;Cho, Nam Geun;Leem, Jungtae
    • Journal of Acupuncture Research
    • /
    • 제39권2호
    • /
    • pp.105-114
    • /
    • 2022
  • Background: The objective structured clinical examination (OSCE) is used in the colleges of Korean Medicine, but few studies have validated the OSCE evaluation criteria or post-education questionnaires. Diagnostic ultrasound is used in Korean medicine treatment including acupuncture, acupotomy, and pharmacopuncture to increase the safety and efficacy of treatment. We aimed to develop and validate a OSCE checklist and questionnaire for diagnostic musculoskeletal ultrasound training. Methods: A OSCE checklist and rubric for diagnostic ultrasound training, and questionnaire was developed using literature research. Eight expert panelists verified each draft item in a single-round survey. Items with a content validity ratio (CVR) < 0.75 were excluded or modified to reflect the experts' opinions. Results: The OSCE checklist and rubric for diagnostic ultrasound training focusing on volar wrist and carpal tunnel syndrome included: 15 items revised according to CVR and expert opinions, the pre-examination procedure, structures to be identified by ultrasound, scans with 2 diagnostic criteria for carpal tunnel syndrome, an explanation of the exam results, and the post exam procedure. The questionnaire consisted of 15 items, including the overall evaluation of training, the effect of the OSCE, and the perception of the ultrasound. All 6 self-evaluation items were not revised, as they had a CVR of ≥ 0.75. Conclusion: An ultrasound OSCE for scanning the volar wrist and diagnosing carpal tunnel syndrome was developed using 15 validated tasks, 15 survey questions about ultrasound training, and 6 questions for self-evaluation. These results may be used in the future for education in diagnostic ultrasound.

스마트폰의 블루투스와 초음파를 이용한 향상된 실내 영역 결정 (Advanced Indoor Zone Detection with Bluetooth and Ultrasound of Smartphone)

  • 권진세;이제민;김형신
    • 대한임베디드공학회논문지
    • /
    • 제11권3호
    • /
    • pp.135-141
    • /
    • 2016
  • Indoor zone-based services have continuously become popular by increased prevalence of smartphones. Bluetooth and ultrasound can be used for zone detection. However, bluetooth does not guarantee precise zone detection if the signal degrades due to the obstacles. Ultrasound can be easily forged by recording sound on the smartphone. For that reason, zone detection based on ultrasound has a security hole. To remedy each limitation, we propose an advanced zone detection method, that combines bluetooth and ultrasound. An authentication server issues a one-time password to the user over bluetooth. The user generates an ultrasound signal that encodes the password. In this manner, the proposed method ensures secure and accurate zone detection.

오존과 초음파를 이용한 실리콘 웨이퍼의 Post Sliced Cleaning (Post Sliced Cleaning of Silicon Wafers using Ozone and Ultrasound)

  • 최은석;배소익
    • 한국재료학회지
    • /
    • 제16권2호
    • /
    • pp.75-79
    • /
    • 2006
  • The effect of ozone and/or ultrasound treatments on the efficiency of slurry removal in post sliced cleaning (PSC) of silicon ingot was studied. Efficiency of slurry removal was evaluated as functions of time, temperature and surfactant with DOE (Design of Experiment) method. Residual slurries were observed on the wafer surface in case of cleaning by ozone or ultrasound separately. However, a clean wafer surface was appeared when cleaned with ozone and ultrasound simultaneously. It has found that cleaning time was the main effect among temperature, time and surfactant. Elevated temperature, addition of surfactant and high ozone concentration helped to accelerate efficient removal of slurry. The improvement of removal efficiency seems to be related to the formation of more active OH radicals. The highly cleaned surface was achieved at 10 wt% ozone, 1 min and 10 vol% surfactant with ultrasound. Application of ozone and ultrasound might be a useful method for PSC process in wafer cleaning.

치료용 초음파의 투과시간과 PTT의 상관관계 분석 (Analysis of Relations Between Transmission Time of Therapeutic Ultrasound and Pulse Transit Time)

  • 김성민;이주환;최병철;정회승;배하석
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2345-2350
    • /
    • 2008
  • Recently, ultrasound is becoming a universal way of treatment when it comes to clinic. The thermal effect of therapeutic ultrasound can raise the temperature of tissue without damage and thus increases the flow rate, and this leads to the oxygen transportation velocity of peripheral tissue and ultimately facilitates the metabolism. The purpose of this research is analyzing relations between PTT and transmission time of therapeutic ultrasound, and in this study the PTT variation due to respective transmission time of ultrasound upon 17 normal persons was measured and as a result, it was observed that PTT increases as transmission time of therapeutic ultrasound

Low-frequency Ultrasound Enhanced Transdermal Drug Delivery Across Rat Skin

  • 이화진;김종율;박진남;신영희
    • Journal of Pharmaceutical Investigation
    • /
    • 제37권6호
    • /
    • pp.365-368
    • /
    • 2007
  • The primary aim of this study was to investigate the enhancement effect of low-frequency ultrasound on skin permeation. In vitro permeation experiments were performed using Franz modified diffusion cells with ketoprofen as model drug. The effect of various ultrasound factors-ultrasound application mode (continuous mode and discontinuous mode), ultrasound intensity (0.26 $W/cm^2$, and 0.29 $W/cm^2$) and duty cycle (3%, 16%, 50%, and 83%) were studied. The highest permeation was observed at 0.29 $W/cm^2$ intensity, 50% duty cycle, and discontinuous mode. The result suggested the feasibility of low frequency ultrasound application for the phonophoretic transdermal drug delivery system.

근골격계 초음파의 기판 조절 입문: B Mode와 Doppler (Introduction to Knobology Focusing on B Mode and Doppler Setting in Musculoskeletal Ultrasound)

  • 민경훈
    • Clinical Pain
    • /
    • 제20권1호
    • /
    • pp.7-14
    • /
    • 2021
  • Musculoskeletal ultrasound has evolved as the essential tool to diagnose and guide intervention procedures in people with neuromusculoskeletal conditions. Image optimization and understanding device operations are core components for ultrasound guided intervention procedure training. All ultrasound machines share the common operative features and there are various buttons for the features in the device control panel. Ultrasound "knobology" refers to the thorough understanding of imaging optimization. This review addressed basic information for the transducers, depth setting, gain and focus control, different modes focusing on brightness and doppler modes.

Ultrasound-guided interventions for controlling the thoracic spine and chest wall pain: a narrative review

  • Park, Donghwi;Chang, Min Cheol
    • Journal of Yeungnam Medical Science
    • /
    • 제39권3호
    • /
    • pp.190-199
    • /
    • 2022
  • Ultrasound-guided injection is useful for managing thoracic spine and chest wall pain. With ultrasound, pain physicians perform the injection with real-time viewing of major structures, such as the pleura, vasculature, and nerves. Therefore, the ultrasound-guided injection procedure not only prevents procedure-related adverse events but also increases the accuracy of the procedure. Here, ultrasound-guided interventions that could be applied for thoracic spine and chest wall pain were described. We presented ultrasound-guided thoracic facet joint and costotransverse joint injections and thoracic paravertebral, intercostal nerve, erector spinae plane, and pectoralis and serratus plane blocks. The indication, anatomy, Sonoanatomy, and technique for each procedure were also described. We believe that our article is helpful for clinicians to conduct ultrasound-guided injections for controlling thoracic spine and chest wall pain precisely and safely.

저가형 초음파 영상처리 장치의 개발 (Development of Low Price Ultrasound Image Processing System)

  • 이근유;전양배;김정훈;김상봉
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.53-58
    • /
    • 2001
  • In this paper, a low price ultrasound image processing system is developed using DSP and PC. Ultrasound for image is generated by the 32-channel transducer. Ultrasound image is captured by DSP instead of the private image grabber board. Display of image and image processing algorithms are performed by PC. The image processing algorithms based on GUI are realized by software. So users without knowledge of image processing can perform the image enhancement more easily.

  • PDF

초음파 영상의 콘트라스트 향상을 위한 전역적, 적응적 방법의 융합 (Fusion of Global and Adaptive Methods for Contrast Enhancement of Ultrasound Images)

  • 윤재호;박래홍
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2007년도 하계종합학술대회 논문집
    • /
    • pp.357-358
    • /
    • 2007
  • Contrast enhancement in the field of ultrasound imaging contributes to improve the accuracy of medical diagnosis by enhancing the visibility of ultrasound images. This paper proposes a contrast enhancement method that improves the contrast of ultrasound images both globally and locally by fusing global and adaptive contrast enhancement methods. Experimental results show that our approach yields more competitive results than the existing global and adaptive contrast enhancement methods in enhancing the visibility of ultrasound images.

  • PDF