• 제목/요약/키워드: underground pipeline

검색결과 160건 처리시간 0.036초

상수도관로의 주변 지반침하 위험도 평가를 위한 안전감시 센서 (Safety Monitoring Sensor for Underground Subsidence Risk Assessment Surrounding Water Pipeline)

  • 곽필재;박상혁;최창호;이현동
    • 센서학회지
    • /
    • 제24권5호
    • /
    • pp.306-310
    • /
    • 2015
  • IoT(Internet of Things) based underground risk assessment system surrounding water pipeline enables an advanced monitoring and prediction for unexpected underground hazards such as abrupt road-side subsidence and urban sinkholes due to a leak in water pipeline. For the development of successful assessment technology, the PSU(Water Pipeline Safety Unit) which detects the leakage and movement of water pipes. Then, the IoT-based underground risk assessment system surrounding water pipeline will be proposed. The system consists of early detection tools for underground events and correspondence services, by analyzing leakage and movement data collected from PSU. These methods must be continuous and reliable, and cover certain block area ranging a few kilometers, for properly applying to regional water supply changes.

The Field Test of a Mitigation Method from DC Subwaysystem for Underground Pipeline

  • Bae, Jeong-Hyo;Ha, Tae-Hyun;Ha, Yoon-Cheol;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Corrosion Science and Technology
    • /
    • 제6권6호
    • /
    • pp.308-310
    • /
    • 2007
  • The owner of underground metallic structures (gas pipeline, oil pipeline, water pipeline, etc) has a burden of responsibility for the corrosion protection in order to prevent big accidents like gas explosion, soil pollution, leakage and so on. So far, Cathodic Protection(CP) technology have been implemented for protection of underground systems. The stray current from DC subway system in Korea has affected the cathodic protection (CP) design of the buried pipelines adjacent to the railroads. In this aspect, KERI has developed a various mitigation method, drainage system through steel bar under the rail, a stray current gathering mesh system, insulation method between yard and main line, distributed ICCP(Impressed Current Cathodic System), High speed response rectifier, restrictive drainage system, Boding ICCP system. We installed the mitigation system at the real field and test of its efficiency in Busan and Seoul, Korea. In this paper, the results of field test, especially, distributed ICCP are described.

산업단지 고압매설배관 안전관리 고찰 (A Study on the Safety Management of High Pressure Underground Pipeline in Industrial estate)

  • 최현웅;정세광;김진준
    • 한국가스학회지
    • /
    • 제21권6호
    • /
    • pp.30-38
    • /
    • 2017
  • 1960년대에 설립된 울산 및 여수 산업단지 고압가스매설배관은 누출 시 피해가 큰 독성가스는 물론 도시가스보다 무겁고 연소범위가 낮은 가연성가스가 그물망처럼 매설사용 중에 있다. 특히, 산업단지 배관의 경우 20년 이상 노후된 배관이 과반이상으로 점유하고 있다. 이와 같이 산업단지 배관은 상주시공감리제도 도입이전에 매설설치 되었으나, 도시가스 매설배관과 달리 법적 의무 없이 자율적으로 배관관리를 하고 있다. 본 연구에서는 산업단지 고압매설배관과 도시가스 매설배관의 안전관리 실태현황, 법을 비교, 피해영향범위 분석 하고 이를 산업단지 고압매설배관의 배관점검모델 마련에 활용하여 산업단지 고압매설배관의 안전성 향상에 기여하고자 한다.

가스배관과 철탑접지의 이격거리 관련 기준 (Standards of Distance between Gas Pipeline and Tower Ground)

  • 이현구;하태현;하윤철;배정효;김대경
    • 한국가스학회:학술대회논문집
    • /
    • 한국가스학회 2006년도 추계학술발표회 논문집
    • /
    • pp.191-195
    • /
    • 2006
  • 전력선에 지락고장이 발생할 경우 대지로 유입된 고장전류에 의하여 인접한 배관에 아크 용융이 발생하면 가스폭발이나 기름유출과 같은 대형사고를 발생시킬 수 있으며, 배관의 유지 및 보수를 담당하는 작업자의 안전에도 위험을 초래할 수 있다. 본 논문에서는 대지를 통한 철탑과 배관 사이의 아크 발생에 대하여 알아보고, 국내외에서 사용되고 있는 철탑 인근에 매설된 배관의 이격거리 기준을 조사하였다.

  • PDF

지하철 누설전류가 도시가스 배관에 미치는 영향 해석 (Analysis of DC Traction Stray Current Interference on Buried Pipelines)

  • 이현구;하태현;하윤철;배정효;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1376-1378
    • /
    • 2004
  • When an underground pipeline runs parallel with DC traction systems, it suffers from DC traction interference. Because the train is fed by the substation through the overhead wire and return current back to the substation via the rails. If these return rails are poorly insulated from earth, DC current leak into the earth and can be picked up by nearby pipeline. It may bring about large-scale accidents even in cathodically protected systems. In this paper we analyze the cathodic protection systems of buried pipelines and DC traction stray current influence on it using the simulation software CatPro. We can discuss the problems and mitigation of DC traction interference for protected pipeline.

  • PDF

A Fuzzy Inference based Reliability Method for Underground Gas Pipelines in the Presence of Corrosion Defects

  • 김성준;최병학;김우식;김익중
    • 한국지능시스템학회논문지
    • /
    • 제26권5호
    • /
    • pp.343-350
    • /
    • 2016
  • Remaining lifetime prediction of the underground gas pipeline plays a key role in maintenance planning and public safety. One of main causes in the pipeline failure is metal corrosion. This paper deals with estimating the pipeline reliability in the presence of corrosion defects. Because a pipeline has uncertainty and variability in its operation, probabilistic approximation approaches such as first order second moment (FOSM), first order reliability method (FORM), second order reliability method (SORM), and Monte Carlo simulation (MCS) are widely employed for pipeline reliability predictions. This paper presents a fuzzy inference based reliability method (FIRM). Compared with existing methods, a distinction of our method is to incorporate a fuzzy inference into quantifying degrees of variability in corrosion defects. As metal corrosion depends on the service environment, this feature makes it easier to obtain practical predictions. Numerical experiments are conducted by using a field dataset. The result indicates that the proposed method works well and, in particular, it provides more advisory estimations of the remaining lifetime of the gas pipeline.

전력선 접지와 매설배관의 이격거리 실증실험 사례 조사 (Investigation of the Experiment for Separation Distance between Powerline Earth and Pipelines)

  • 이현구;하태현;하윤철;배정효;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 전기설비
    • /
    • pp.87-88
    • /
    • 2006
  • There are a number of reported instances of actual pipeline rupture during power line faults caused by melting of the pipe wall. This type of hazard was considered to be among the most serious of AC effects on pipelines in an international survey, comparable to the personnel safety hazard. Moreover, resistance coupling is not only a risk when the pipeline parallels a power line but also when they cross. One method of minimizing the effects of resistive coupling is by maintaining an appropriate separation distance between the pipeline and tower. This paper investigate the experiment for separation distance between the powerline earth and pipelines.

  • PDF

지하매설 수소 배관망 안전 모니터링 시스템의 개념 설계: 광섬유 기반 모니터링 사례를 중심으로 (Conceptual Design for Underground Hydrogen Pipeline Monitoring System: Case Study on Fiber Optic Sensing)

  • 박재우;염동준
    • 한국산업융합학회 논문집
    • /
    • 제25권4_2호
    • /
    • pp.673-686
    • /
    • 2022
  • Recently, as the importance of eco-friendly energy has increased hydrogen gas is in the spotlight as future energy. Due to its special properties, hydrogen gas is more difficult to detect requiring more precise sensing technology. The primary objective of this study is to design a concept of an underground hydrogen pipeline monitoring system. For this, the following research works are conducted sequentially; 1)selection of core technology for conceptual design, 2)state-of-the-art review, 3)design of a concept of the system. As a result, DAS(Distributed Acoustic Sensing), and DTS(Distributed Temperature Sensing) are selected as each core technology. Furthermore, a conceptual design of an underground hydrogen pipeline monitoring system is deducted. It is expected that the impact on the eco-friendly energy industry will be enormous due to the increasing interest in using hydrogen energy.

뉴질랜드 크라이스트처어치 지진에 의해 발생된 영구지반변형과 매설된 상수도관 성능평가 (Permanent Ground Deformation induced by Christchurch Earthquake and Estimation of Underground Water Pipeline Performance in New Zealand)

  • 전상수
    • 한국산학기술학회논문지
    • /
    • 제16권6호
    • /
    • pp.4201-4207
    • /
    • 2015
  • 본 연구에서는 최근 뉴질랜드의 Christchurch 지역의 2011년 2월 22일의 지진규모(Mw) 6.2 지진발생 후 얻어진 데이터를 이용하여 지진에 의한 지하 상수도관 시스템의 성능에 주안점을 두고 연구를 수행하였다. 이 논문은 액상화로 인하여 발생된 영구지반변형지역과 서로 다른 재질의 상수도관에 따라 1 km 당 손상갯수로 산정되는 손상율을 액상화 지역에서의 지진발생 전후에 얻어진 높은 해상도의 라이다데이터로부터 계산된 부등침하와 횡방향 지반변형률의 관계를 통하여 산정하였다. 본 연구에서는 영구지반변형에 따른 매설된 상수도관의 지진성능을 요약하여 설명하였으며 연구결과 연성이 매우 큰 폴리에틸렌 상수도관이 매우 우수한 지진성능을 가지고 있음을 알 수 있다.

전철 간섭 대책용 분포형 외부전원시스템의 배관인출 방법에 따른 영향 (Influence on Lead Wire Method of Distributed ICCP Systems for Mitigation of DC Traction Interference)

  • 이현구;하윤철;하태현;배정효;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.282-284
    • /
    • 2005
  • When an underground pipeline runs parallel with DC traction systems, it suffers from DC traction interference. Because the train is fed by the substation through the overhead wire and return current back to the substation via the rails. If these return rails are poorly insulated from earth, DC current leak into the earth and can be picked up by nearby pipeline. It may bring about large-scale accidents even in cathodically protected systems. In this paper we analyze the influence on lead wire method of distributed ICCP(impressed current cathodic protection) systems for mitigation of DC traction interference using the simulation software CatPro.

  • PDF