• Title/Summary/Keyword: unstable fracture

Search Result 175, Processing Time 0.029 seconds

The Use of Hook Plate on the Management of Unstable Neer II Lateral End Fracture of The Clavicle (불안정한 Neer II형 원위쇄골 골절의 치료에서 Hook 금속판의 이용)

  • Ko, Sang-Hun;Cho, Sung-Do;Park, Moon-Soo;Ryu, SuGoo
    • Clinics in Shoulder and Elbow
    • /
    • v.6 no.2
    • /
    • pp.131-137
    • /
    • 2003
  • Purpose: Unstable Neer type II lateral end fracture of clavicle may be required operation. The purpose of this study is the effectiveness of the use of Hook plate in the management of unstable Neer type II fractures. We preliminary reported the results of Unstable Neer type II lateral end fracture of clavicle using by Hook plate. Material and Methods: From May 1998 to May 2002, we operated 6 cases unstable Neer type II lateral end fracture of clavicle with Hook plate by one surgeon. We checked radiologic evaluation and disappearance of pain per 1 week, and evaluated improvement of range of motion per 2 week. And we followed up at each interval 3 months,6 months, 12 months and after that per 6months interval, at that each time we checked stress radiogram of shoulder and functional evaluation. The shoulder function was evaluated using Modified Shoulder Rating Scale (MSRC) for Distal Clavicle Fracture and UCLA score. Average follow up was on 37.2 (12∼57) months. Results: All 6 patients were regained satisfactory function. Average MSRC for distal clavicle fracture was 17.3 (15∼20) and average UCLA score was 33.2 (31∼35) at last follow up. Conclusion: There are many advantage of the use of Hook plate on management of unstable Neer II distal clavicle fracture in spite of several disadvantage. There have not yet been reported in our country. So we obtained good to excellent clinical result in surgical treatment of 6 cases on type II displaced lateral end fracture of the clavicle. But we think that more cases will be review and longer follow up will be needed in the future.

Operative Treatment of Unstable Fracture of the Proximal Humerus (상완골 근위부 불안정성 골절의 수술적 치료)

  • Kim Young-Kyu;Jang Young-Hun;Kim Keon-Beom
    • Clinics in Shoulder and Elbow
    • /
    • v.1 no.2
    • /
    • pp.198-204
    • /
    • 1998
  • Unstable fractures of the proximal humerus continue to be difficult problems for orthopaedic surgeons. The optimum treatment of these fractures has remained a matter of controversy. We analyzed the clinical results of open reduction and plate fixation underwent for patients of unstable fractures of proximal humerus after minimum 12 months follow up. The purpose of this study is to evaluate the efficacy of open reduction and rigid plate fixation. Twenty-two patients were managed with open reduction and plate fixation. Mean follow up duration was 20.6 months(range, 12 to 28 mon.). Because the age of patient as a maker of degree of osteoporosis was considered the key factor in the success of anatomic reconstruction, we divided into two groups according to age. Group A was comprised of 12 cases with younger than 50 yrs of age. Ten cases of older than 50 yrs of age were Group B. According to Neer's classification, five cases(22%) were two part fracture, 12 cases(64%) were three part fracture, and three cases(14%) were four part fracture. We used the Neer rating system for evaluating the results. In Group A, overall scores were 79.1. In Group B, overall scores were 76.8. Overall scores in two part fracture were 85, overall scores in three part fracture 78.4 and overall scores in three part fracture 68.3. We achieved excellent or good results in nine cases(75%) of Group A and seven cases(70%) of Group B. Also, we obtained excellent or good results in all cases of two part fracture, ten cases(71%) of three fracture and one case(33%) of four part fracture. The complications were three metal loosening, one avascular necrosis of humeral head, one severe stiff shoulder, one superficial wound infection and one ectopic ossification. The results were excellent or good in 16 cases(73%) out of 22 cases. In conclusion, rigid fixation and supervised early exercise would be a good option for unstable fracture of the proximal humerus.

  • PDF

Are "Unstable" Burst Fractures Really Unstable?

  • Woo, Jun Hyuk;Lee, Hyun Woo;Choi, Hong June;Kwon, Young Min
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.6
    • /
    • pp.944-949
    • /
    • 2021
  • Objective : The stability is an important factor to decide the treatment plan in thoracolumbar burst fracture patients. Patients with an unstable burst fracture generally need operative management. Decrease in vertebral body height, local kyphosis, involvement of posterior column, and/or canal compromise are considered important factors to determine the treatment plan. On the other hand, in thoracolumbar injury classification system (TLICS), surgery is recommended in patients with TLICS of more than 5 points. The purpose of this study was to apply the TLICS score in patients with thoracolumbar burst fractures and to distinguish the differences of treatment plan on burst fracture. Methods : All patients, diagnosed as a thoracolumbar burst fracture between January 2006 and February 2019 were included in this study. Unstable thoracolumbar burst fracture was defined as burst fracture with neurologic deficit, three-column injury, kyphosis over 30 degrees, decrease of anterior body height over 40 percent and canal comprise more than 50%. TLICS score was measured with morphology, neurological involvement and posterior ligamentous complex integrity. The existence of instability was compared with TLICS score. Results : Total 233 patients (131 men, 102 women) were included in this study. In Denis classification, 51 patients (21.9%) diagnosed as stable burst fracture while 182 patients (78.1%) had unstable burst fracture. According to TLICS, 72 patients (30.9%) scored less than 4, while 161 patients (69.1%) scored 4 or more. All the patients with stable burst fracture scored 2 in TLICS. Twenty-one patients (9.0) scored 2 in TLICS but diagnosed as unstable burst fracture. Thirteen patients had over 40% of vertebra body compression, four patients had more than 50% of canal compromise, three patients had both body compression over 40% and kyphosis over 30 degrees, one patients had both body compression and canal compromise. Fifteen patients presented kyphosis over 30 degrees, and three (20%) of them scored 2 in TLICS. Seventy-three patients presented vertebral body compression over 40% and 17 (23.3%) of them scored 2 in TLICS. Fifty-three patients presented spinal canal compromise more than 50%, and five (9.4%) of them scored 2 in TLICS. Conclusion : Although the instability of thoracolumbar burst fracture was regarded as a critical factor for operability, therapeutic strategies by TLICS do not exactly match with the concept of instability. According to the concept of TLICS, it should be reconsidered whether the unstable burst fracture truly unstable to do operation.

Coracoclavicular Screw Fixation for AC Dislocation and Unstable Distal Clavicle Fracture (견봉 쇄골 탈구와 쇄골 외측단 골절에서 일시적 오구 쇄골간 나사못 고정술)

  • Kim Jin Sub;Jun Jin Ho;Chung Yung Khee
    • Clinics in Shoulder and Elbow
    • /
    • v.2 no.2
    • /
    • pp.133-137
    • /
    • 1999
  • Purpose: There are so many different methods with the their own advantages and disadvantages for acute AC dislocation and distal unstable clavicle fracture. We evaluated the usefulness of temporary Bosworth's coracoclavicular fixations using the cannulated screw and reviewed our clinical results. Materials and Methods: We evaluated 34 cases of temporary coracoclavicular fixations with cannulated screw and washer for acute AC dislocation(25cases in the Type V, Ⅲ) and distal unstable clavicle fracture(9cases in the Type ⅡB, Ⅱ+Ⅲ). All cases were fixed by the same techniques, guided cannulated screw under C-arm after the repair of the CC ligament within 1 week. Bases on the regular check, screws were removed at the 6-12 weeks under local anesthesia. The final clinical and radiological results(average 14 months follow-up) were rated with the UCLA scale. Results : All shoulders were gained nearly full ROM passively at the 3-4 weeks. The overall satisfactory resuIts(excellent or good) were achieved 88%(22/25) in the acute AC dislocation and all in the distal unstable clavicle fracture. There were no definite complications except three initial fixations loosening. Conclusion: Temporary Bosworth's coracoclavicular fixation using the cannulated screw with guided pin was simple precedure and provided enough initial stability for acute AC dislocation and distal unstable clavicle fracture.

  • PDF

Effectiveness of Dual-Maneuver Using K-Wire and Dingman Elevator for the Reduction of Unstable Zygomatic Arch Fracture

  • Yoon, Hyungwoo;Kim, Jiye;Chung, Seum;Chung, Yoon-Kyu
    • Archives of Craniofacial Surgery
    • /
    • v.15 no.2
    • /
    • pp.59-62
    • /
    • 2014
  • Background: The zygoma is the most prominent portion of the face. Almost all simple zygomatic arch fractures are treated in a closed fashion with a Dingman elevator. However, the open approach should be considered for unstable zygomatic arch fractures. The coronal approach for a zygomatic arch fracture has complications. In this study, we introduce our method to reduce a special type of unstable zygomatic fracture. Methods: We retrospectively reviewed zygomatic arch view and facial bone computed tomography scans of 424 patients who visited the Wonju Severance Christian Hospital from 2007 to 2010 with zygomaticomaxillary fractures, among whom 15 patients met the inclusion criteria. Results: We used a Dingman elevator and K-wire simultaneously to manage this type of zygomatic arch fracture. Simple medial rotation force usually collapses the posterior fractured segment, and the fracture becomes unstable. Thus, the posterior fracture segment must be concurrently elevated with a Dingman elevator through Keen's approach with rotation force applied through the K-wire. All fractures were reduced without any instability using this method. Conclusion: We were able to reduce unstable and difficult zygomatic arch fractures without an open incision or any external fixation device.

Comparisons of Fracture Types and Pelvic Angiographic Findings in Hemodynamically Unstable Pelvic Bone Fracture (혈역학적으로 불안정한 골반골 골절 환자에서 골반골 골절 소견과 혈관조영술 소견의 비교)

  • Lee, Kwon Il;Lee, Kang Hyun;Kang, Sung Chan;Park, Sung Min;Jang, Yong Su;Shin, Tae Yong;Hwang, Sung Oh;Kim, Hyun
    • Journal of Trauma and Injury
    • /
    • v.20 no.1
    • /
    • pp.26-32
    • /
    • 2007
  • Purpose: Hemorrhagic shock is the leading cause of death in patients with pelvic bone fractures. The majority of blood loss is due to injured pelvic arteries and retroperitoneal veins and to bleeding from the fracture site itself. Pelvic angiography and embolization of injured vessels is an effective way to control continuous bleeding. However, identifying the bleeding focus in hemodynamically unstable patients before diagnostic intervention is difficult. The purpose of this study was to determine the correlation between fracture patterns in hemodynamically unstable patients with pelvic fractures and later pelvic angiography findings. Methods: We performed a retrospective study of 21 hemodynamically unstable patients with pelvic fractures admitted to our emergency department between April 2001 to April 2006. All 21 patients underwent pelvic angiography. Pelvic fractures were assessed according to the Tile's classification and the degree of injury was assessed using the Injury Severity Score (ISS) and Revised Trauma Score (RTS). The hemodynamic status of the patients was defined using vital signs, base excess, and blood lactate. Fracture patterns were compared with hemodynamic status and angiography findings. Results: In the 5year study period, 21 hemodynamically unstable pelvic bone fracture patients were admitted; ten were men (47.6%), and 11 were women (52.4%). The mean age was 41.1 years (range: ${\pm}20.1$). Of the 21 embolization was performed in 6 patient (28.6%): 1 patient of the 5 unstable pelvic bone fracture patients (20%), and 5 patients of 16 the stable pelvic bone fracture patients (31.3%). There were no significant differences between the RTS (p=0.587) and embolization rate (p=0.774) for either the stable patients or the unstable patients. Patients with arterial injury on angiography had a lower RTS compared with patients without arterial injury but there was no significant difference in ISS between the two groups. The angiographic injured sites were five internal femoral arteries and one external femoral artery. Conclusion: The findings in this study suggest that the pelvic fracture pattern in hemodynamically unstable patients with pelvic fractures does not correlate with pelvic angiography findings.

Short Segment Pedicle Screw Fixation with Augmented Intra-Operative Vertebroplasty in Unstable Thoraco-Lumbar Fracture - Preliminary Report - (불안정성 흉·요추부 골절에 대한 단 분절 척추경 나사못 고정술 및 추체 보강 성형술 - 예 비 보 고 -)

  • Kim, Young Woo;Oh, Sung Han;Yoon, Do Heum;Chin, Dong Kyu;Cho, Yong Eun;Kim, Young Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.11
    • /
    • pp.1271-1277
    • /
    • 2001
  • Objectives : Since vertebroplasty has been introduced, we performed short segment pedicle screw fixation with augmented intra-operative vertebroplasty in patients with unstable thoraco-lumbar fracture. Our intentions are to demonstrate the efficacy and indication of this new technique compare to conventional methods. Material and Methods : The surgery comprised of pedicle screw fixations on one level above and below the fracture site, and the fractured level itself, if pedicle is intact, and intra-operative vertebroplasty under the fluoroscopic guide with in-situ postero-lateral bone graft. Also, in cases of bone apposition, we removed those with small impactor through a transfascetal route. During the last 2 years, we performed in seven(7) unstable thoraco-lumbar fracture patients who consisted of two different characteristics, those four(4) with primary or secondary osteoporosis and three(3) of young and very healthy. All patients were followed clinically by A.S.I.A. score and radiography. Results : Mean follow up period was 14 months. We observed well decompressed state via transfascetal route in cases of bone fragments apposition and no hardware pullout in osteoporotic cases, no poly-methyl-methacrylate (PMMA) leakage through the fracture sites into the spinal canal, and no kyphotic deformities in both cases during follow-up periods. All patients demonstrated solid bony fusion except one following osteoporotic compression fracture on other sites. Conclusions : In the management of unstable thoraco-lumbar fracture, we believe that this short segment pedicle screw fixation with augmented intra-operative vertebroplasty reduce the total length or levels of pedicle screw fixation without post-operative kyphotic deformity.

  • PDF

Percutaneous Pinning in Unstable Two-parts Fracture of Surgical Neck in Humerus (상완골 불안정성 외과적 경부 이분 골절의 경피적 핀 삽입 고정술)

  • Park Jin-Young;Rho Han-Jin;Kim Myung-Ho
    • Clinics in Shoulder and Elbow
    • /
    • v.3 no.1
    • /
    • pp.26-32
    • /
    • 2000
  • Purpose : The aim of this study is the assessment of the clinical outcomes after percutanous pinning of unstable two-parts fracture of surgical neck in humerus. Materials and Methods: This study was based on thirteen cases of non-comminuted unstable surgical neck fracture of humerus among 19 cases, which followed-up more than one year. Follow-up averaged 29 months. We treated with percutaneous pinning techniques and assessed clinical outcomes. Functional evaluation was performed using the standard method of research committee of American Shoulder and Elbow Surgeons(ASES). Results: Last follow-up ROM of shoulder joint were 142 degrees of forward elevation, 57 degrees of external rotation, 72 degrees of external rotation in 90 degrees abduction, and T8 of internal rotation. Pain scale was l(range : 0∼3). ASES scores was 86.2(range : 63.3~98.3). Patient satisfaction based on ASES were excellent in 6 cases, good in 5 cases, fair in 1 case, poor in 1 case. A case of fair result was caused by limitation of motion in shoulder joint and poor case was paraplegia patient after traffic accident. Conclusion : Percutaneous pinning is recommended for non-comminuted unstable fracture of surgical neck in humerus.

  • PDF

Damage and fracture processes of concrete using acoustic emission parameters

  • Fan, Xiangqian;Hu, Shaowei;Lu, Jun
    • Computers and Concrete
    • /
    • v.18 no.2
    • /
    • pp.267-278
    • /
    • 2016
  • In order to observe the internal damage of concrete in real time, we introduced acoustic emission nondestructive detecting technology into a series of fracture tests; the test results revealed the whole process that concrete undergoes when it sustains damage that leads to failure, according to the change rules of the acoustic emission parameters. The results showed that both the initiation and unstable loads can be accurately determined using the abrupt change of the acoustic emission rate curves and the turning point of the acoustic emission parameters' accumulative curves. The whole process, from damage to failure, includes five phases, beginning with damage, such as cracking, a stable crack growth process, a critical unstable stage, and unstable propagation. The brittle fracture characteristics of concrete change when steel bars are joined, because the steel bars and the concrete structure bond, which causes an increase in the acoustic emission signals within the fracture process of the reinforced concrete. The unstable propagation stage is also extended. Our research results provide a valid methodology and technical explanations, which can help researchers to monitor the cracking process of concrete structures, in real time, during actual projects.

The Clinical Study on 40 Cases of Patient with Thoracolumbar Fracture (흉·요추 골절 환자 40례에 대한 임상적 고찰)

  • Oh, Hei-hong;Kim, Il-du;Byun, Jae-yung;Ahn, Soo-gi
    • Journal of Acupuncture Research
    • /
    • v.18 no.2
    • /
    • pp.227-236
    • /
    • 2001
  • Objectives : This study was performed to evaluate the clinical results of the thoracolumbar fracture patients treated with oriental medical methods. Methods : We reviewed 40 patients of thoracolumbar fracture, who were hospitalized at WonKwang University KwangJu Oriental Medical Hospital and treated by oriental medical methods. We classified thoracolumbar fracture according to three column theory and then analyzed the cause of injury, sex-age distribution, treatment, and etc.. Results : 1. The distribution showed female predominance(72.5%) in sex and 70age-bracket predominance in age. 2. In the distribution of causes, the largest group was "lifting heavy objects"(40%) and the next was "slip down"(37.5%). 3. In the duration of symptoms, the largest group was the group of "acutest" (40%). 4. The distribution of injured level was L1 body the most(20%). 5. In classification of fracture, "compression fracture" was the most(57.5%) and the next was "burst fracture", "unstable fracture" in order. 7. Therapeutic effects above "fair" were 37 cases(92.5%). 8. The higher grade of clinical symptoms is, the lower therapeutic effect is. 9. In the distribution of treatment results according to classification of fracture, both the compression fracture and the burst fracture were almost same high and the unstable fracture is relatively lower than them. Conclusions : The result to treating thoracolumbar fracture by oriental medical methods is satisfactory.

  • PDF