• Title/Summary/Keyword: vector network analyzer

Search Result 94, Processing Time 0.036 seconds

Optimization of Ferromagnetic Resonance Spectra Measuring Procedure for Accurate Gilbert Damping Parameter in Magnetic Thin Films Using a Vector Network Analyzer

  • Kim, D.H.;Kim, H.H.;You, Chun-Yeol;Kim, Hyung-Suk
    • Journal of Magnetics
    • /
    • v.16 no.3
    • /
    • pp.206-210
    • /
    • 2011
  • We optimize a vector network analyzer ferromagnetic resonance (VNA-FMR) measurement system to study spin dynamics and Gilbert damping parameters of thin ferromagnetic films. In order to obtain accurate damping parameters, careful determination of the susceptibility line-width is required. The measured S-parameters are converted into the corresponding susceptibility through a calibration processes. From the line-width measurements, we can successfully extract the saturation magnetizations and Gilbert damping parameters of 5-, 8-, and 10-nm thick $Ni_{81}Fe_{19}$ (Py) films.

The Response to Impulse Signal on Three Phase Transformer using Vector Network Analyzer (벡터 회로망 분석기 측정을 기반으로 한 3상 변압기의 시간영역 펄스 신호에 대한 응답 분석)

  • Kim, Kwangho;Jung, Jongman;Nah, Wansoo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.79-84
    • /
    • 2015
  • Transformer is widely used element on power system and industrial area. Especially the transformers installed at power system are exposed to an environment of arbitrary changed. Thus the prediction of degradation and the analysis of response to impulse are important. To conduct those works, the electrical characteristics of system should be analyzed, effectively. But the analysis of electrical characteristic in electric machine level such as pole and pad-mounted transformer is almost no, thus commercial VNA (Vector Network Analyzer) is used to getting the response in wide frequency range. However, the output power of VNA is usually under 10mW, so verification for effectiveness of measuring electrically large component should be conducted, firstly. Next, after getting total S-parameter of transformer, predicting impulse response can be performed in time-domain with circuit simulator. In this paper, it is introduced that verification effectiveness of VNA using transfer function from SFRA (Sweep Frequency Response Analyzer), firstly. Next, total S-parameter, six by six matix form, was built using measured 2 port S-parameter from vector network analyzer. To get the response to impulse which is defined by IEC 60060-1, time-domain simulation is conducted to ADS (Advenced Design System) circuit simulator.

Two-Port Vector Network Analysis System with a Vector Signal Channel (벡터 전압 수신기를 이용한 2-포트 산란 계수 분석 시스템)

  • Lee, Dong-Joon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.5
    • /
    • pp.541-548
    • /
    • 2013
  • This paper presents a vector network analysis system for 2-port scattering parameters of microwave devices using some basic microwave instruments/devices such as signal generators, vector voltmeter, directional couplers and frequency mixers. The analytical model and implementation method for scattering parameter measurements - which can replace the vector network analyzers - are presented. The performance of the implemented system is evaluated through 1- and 2-port scattering parameter measurements, respectively. The vector volt signals which determine the scattering parameters are detected in two distinct methods depending on the frequency band of interests; a direct-detection method with a single signal generator and vector voltmeter for relatively low band and a heterodyne method to frequency down-mix associated with an additional signal source as well as frequency mixers for high band are used, respectively. Using these two methods, scattering parameters of UHF and X bands are evaluated and their performances are verified through a comercial vector network analyzer.

Vector Network Analyzer Ferromagnetic Resonance Study of Py Thin Films (Vector Network Analyzer를 이용한 Py 박막의 강자성공명연구)

  • Shin, Yong-Hwack;Ha, Seung-Seok;Kim, Duck-Ho;You, Chun-Yeol
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.1
    • /
    • pp.18-23
    • /
    • 2010
  • Ferromagnetic resonance (FMR) measurement is an important experimental technique for the study of magnetic dynamics. We designed and set up the vector network analyzer ferromagnetic resonance (VNA-FMR) measurement system with home made coplanar waveguides (CPW). We examined 10-, 20-, 40-nm thick Py thin films to test the performance of the VNA-FMR measurement system. We measured S-parameter (transmission/reflection coefficient) of Py thin films on a CPW. Resonance frequency is investigated from 2.5 to 7 GHz for a field range from 0 to 490 Oe. The VNA-FMR data shows the resonance frequency increment when the external magnetic field increases. We also investigated Gilbert damping constant of Py thin film using resonance frequency (${\omega}_r$) and linewidth ($\Delta\omega$). After investigating dependence of thickness, we find that an decrease in S-parameter intensity as Py thin film thickness decreases. And the FMR results show that the effective saturation magnetization, $M_{eff}$, increase from 7.205($\pm$0.013) kOe to 7.840($\pm$0.014) kOe, while the film thickness varies from 10 to 40 nm.

Mixed-mode S-parameter Measurement System of Twisted Pairs (연선의 혼합 모드 산란 계수 측정 시스템)

  • Ahn, Jungsik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.6
    • /
    • pp.888-894
    • /
    • 2018
  • In this paper, we proposed a mixed-mode s-parameter measurement system for measuring the performance of twisted pairs. A twisted pair is a balanced type component, its characteristics can not be directly measured using network analyzer, which is generally implemented as a unbalanced type. It is possible to convert between balanced signal and unbalanced signal by using a balun but it restricts the frequency range of the measurement system. The proposed system measures the performance of twisted pairs by measuring mixed-mode s-parameters using a 4-port vector network analyzer and a designed fixture, without using a balun. We measured the performance of a commercial Ethernet cable and compared with the results which measured by using baluns. The results showed that the proposed system is capable of measuring the performance of twisted pairs.

토양오염도 측정을 위한 Frequency Domain Reflectometry with Vector Network Analyzer(FDR-V) system 적용성 평가

  • Kim Man-Il;Kim Hyeong-Su;Jeong Gyo-Cheol
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.36-41
    • /
    • 2005
  • 복소유전율상수인 실수부(Real part)와 허수부(Imaginary part)를 측정하기 위하여 Frequency Domain Reflectometry with Vector Network Analyzer(FDR-V) 측정 장비로 $1{\sim}18GHz$ 범위 내에서 매질의 기본 구성단위인 공기, 물, 흙입자에 대한 기본적인 유전율 특성을 파악하고, 이들로부터 다공질 매질내 유류 오염물질의 함유 특성을 측정할 수 있다. 또한 제작된 시료에 대한 포화도와 1GHz 범위에 분포하는 실수부 유전율상수와의 관계로부터 매질의 공극내 함유된 물질의 유전율상수 특성에 매우 민감한 반응을 보이므로, 이들로부터 매질의 공극률 내지 유효공극률의 측정이 가능할 것으로 사료된다.

  • PDF

Study of Channel Model Characterization of Human Internal Organ in On-Body System at 2.45 GHz (2.45 GHz On-Body 시스템에서 인체 내부 장기에 따른 채널 모델 특징 연구)

  • Jeon, Jaesung;Choi, Jaehoon;Kim, Sunwoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.1
    • /
    • pp.62-69
    • /
    • 2014
  • In this paper, WBAN(Wireless Body Area Network) On-body system using the surface-oriented antenna about the impact of human internal organs were analyzed through experiments. The received signal strength is measured for effect of human using the human model and the phantom of torso. Experiments are performed in anechoic chamber without moving and measured by Vector Network Analyzer. This paper confirms the effect of human body by comparing the human model and the phantom of torso. And also know the human internal organs effect on the antennas loss of received signal strength by measured data.

Method for High Frequency Modeling of Transformers Using the S-Parameter (S-Parameter를 이용한 변압기의 고주파 모델링 기법)

  • Jung, Hyeonjong;Yoon, Seok;Kim, Yuseon;Bae, Seok;Lim, Yeongseog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.9
    • /
    • pp.677-684
    • /
    • 2018
  • In this paper, we propose a method for high-frequency modeling of transformers using the S-parameter. The open and short circuits of the primary and secondary sides were configured, and the reflection coefficient in each circuit was measured using a vector network analyzer. The equivalent circuit elements were extracted from the measured results to model the high-frequency equivalent circuit, and the validity of the method was verified by comparing the measured S-parameters in a 2-port network with the simulation results.

3.5 mm Coaxial One Port Vector Network Analysis Using Time Domain Reflectometry (반사 펄스의 주파수 해석을 이용한 광대역 3.5 mm 동축형 단일 포트 벡터 회로망 분석법)

  • Lee, Dong-Joon;Kwon, Jae-Yong;So, Joon-Ho;Kang, No-Weon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.8
    • /
    • pp.967-975
    • /
    • 2012
  • This paper presents a method to measure reflection coefficients of microwave devices or antennas based on time domain analysis with sampling oscilloscopes. The reflection coefficients were extracted by the Fourier transformation of echo pulses from devices with respect to the 20 GHz incident pulse signals. The three-error terms, which are commonly used for the correction of a microwave network, were determined using a 3.5 mm calibration kit. In addition, a modified error-correction model associated with a directional coupler for reflection coefficient measurements is introduced. The results were compared with those of measured with a commercial vector network analyzer.