• Title/Summary/Keyword: volatile compounds

Search Result 2,245, Processing Time 0.033 seconds

Dual Photonic Transduction of Porous Silicon for Sensing Gases (이중의 광학적 변화를 이용한 다공성 실리콘 가스센서 제작)

  • Koh, Young-Dae;Kim, Sung-Jin;Jang, Seung-Hyun;Park, Cheol-Young;Sohn, Hong-Lae
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.2
    • /
    • pp.99-104
    • /
    • 2007
  • Porous silicon exhibiting dual optical properties, both $Febry-P{\acute{e}}rot$ fringe (optical reflectivity) and photoluminescence had been developed and used as chemical sensors. Porous silicon samples were prepared by an electrochemical etch of p-type silicon wafer (boron-doped, <100> orientation, resistivity ; $1-10{\Omega}cm$). Two different types of porous silicon, fresh porous silicon (Si-H terminated) and oxidized porous silicon (Si-OH terminated)by the thermal oxidation, were prepared. Then the samples were exposed to the vapor of various organics, such as methanol, acetone, hexane, and toluene. Both reflectivity and photoluminescence were simultaneously measured under the exposure of organic vapors for sensing VOC's. These surface-modified samples showed unique respond in both reflectivity and photoluminescence with various organic vapors. While polar molecules exhibit greater quenching photoluminescence, molecules having higher vapor pressure show greater red shift for reflectivity.

Enrichment of Lactic Acid Bacteria in Salted Fish, Chromis notatus (유산균 강화 자리젓 제조)

  • Ko, Young-Hwan;Kim, Chang-Yong;Kang, Dong-Sub;Ha, Jin-Hwan;Kim, Soo-Hyun;Kang, Young-Joo;Song, Dae-Jin
    • Microbiology and Biotechnology Letters
    • /
    • v.19 no.2
    • /
    • pp.200-207
    • /
    • 1991
  • Jariieot is a local food prepared by fermentation of salted fish, Chromis notatus. Since its NaC' content is around 20% like other fermented seafoods, reduction NaCl concentration is desirable to minimize the risk of health hazard. Addition of KCl and enrichment of lactic acid fermentation were attempted to solve the problems resulting from low salt concentration. NaCl and KCl were added to a fish, Chromis notatus simultaneously at concentrations of 10 to 4% and 5 to 2%, respectively. Lactic acid bacteria and glucose at final concentration of 2% were also mixed with the above-salt treated fish to prepare jarijeot. The jarijeot was examined periodically for chemical changes during aging and compared with reference jarijeot containing only 20% of NaCl to find out an appropriate method for quality improvement. The content of ATP and its related compounds was not affected by the concentration of NaCl or the presence of lactic acid bacteria. Nearly no difference in contents of free amino nitrogen, trimethylamine oxide, trimethylamine and volatile basic nitrogen was observed between the jarijeot containing 20% of NaCl only and that containing 10% of NaCl, 5% of KCl, 2% of glucose and cells of Pediococcus halophilus. Moreover, sensory evaluation of both kinds of jarijeots revealed almost the same scores. The number of cells of P. halophilus was maintained at concentration of $10^5$cell/ml for 60days' fermentation in the above mentioned jarijeot containing 10% of NaCl. Its pH was dropped down to 4.2. Accordingly it is possible to prepare jarijeot enriched with lactic acid bacteria if KCl and glucose are added at concentration of 5% and 2%, respectively, in addition to NaCl at a final concentration of 10%.

  • PDF

Development of Source Profiles and Estimation of Source Contribution for Hazardous Air Pollutants by the Principal Component Analysis in Indoor Air

  • Kim, Yoon-Shin;Hong, Seoung-Cheol;Lee, Cheol-Min;Kim, Jong-Cheol;Jeon, Hyung-Jin;Song, Kyoung-Min;Roh, Young-Man
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.254-258
    • /
    • 2005
  • The purpose of this study is to characterize the indoor-outdoor relationship of airborne pollutants and recognize probable sources in inside and outside individual apartments in Seoul metropolitan. Simultaneous air monitoring in inside and outside of the 16 Korean Apartments classified into 2groups: less than 1 year old and more than 4 years old from October, 2004 to February, 2005were sampled f3r airborne pollutants(volatile organic compounds, formaldehyde, respiratory particles, carbon dioxide and bacteria) using the Korean Indoor Air Quality Official Method. The concentrations of $CO_2$, TVOCs, HCHO, bacteria and PM10 in the less than 1 year old apartments were determined to be $773.6{\pm}422.3ppm$, $4,393.8{\pm}2,758.2{\mu}g/m^3$, $98.0{\pm}56.4{\mu}g/m^3$, $254.0{\pm}186.3CFU/m^3$ and $31.7{\pm}14.8{\mu}g/m^3$, respectively, Also, the concentrations of those in the more than 4 years old apartments were determined to be $798.9{\pm}266.5ppm$, $792.7{\pm}398.3{\mu}g/m^3$, $70.0{\pm}30.7{\mu}g/m^3$, $245.6{\pm}122.0CFU/m^3$, $49.7f28.7{\pm}g/m^3$, respectively. The average ratios of the indoor and outdoor concentrations of $CO_2$, TVOCs, HCHO, bacteria and PM10 were 2.2, 3.6, 3.1, 3.9 and 1.4, respectively. These results of this analysis is suggested that $CO_2$, TVOCs, HCHO, bacteria and PM10 in indoor air are both emitted from source within the apartment environment and partly come from outdoor air. With the above considerations in mind, it is suggested that the research for source contribution of indoor air pollutants should be expanded and the detailed interpretation of the results on these needed further study(using principal component analysis(PCA).

  • PDF

Assessment of VOCs Emission Characteristics from Building Materials such as Wall Paper, Paints, and Adhesives Using Small Chamber Method (소형챔버법을 이용한 건축자재 중 벽지, 페인트 및 접착제의 VOCs 방출특성 평가)

  • Lee Suk-Jo;Jang Seong-Ki;Cho Yong-Sung;Jung Kyung- Mi;Jeong Gi-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.2
    • /
    • pp.191-204
    • /
    • 2005
  • Building and furnishing materials and consumer product are important sources of volatile organic compounds(VOCs) and other aldehydes in the indoor environment. Some available evidence indicates that VOCs can cause adverse health effects to the building occupants and contribute to some of the symptoms of what we call, 'Sick House Syndrome' in Korea. The aims of this study were to evaluate the efficiency of emission system and to investigate comparison of the emission characteristics of different building materials such as wall-papers, paints, and adhesives. The emission of VOCs from building materials were determined in the small chambers defining the temperature, relative humidity, and ventilation rate in this study. VOCs were sampled for 20 minutes using Tenax-TA tubes and analysed by GC-MS with thermal desorption. The stability of conditions for temperature and relative humidity in this small chamber system showed that the fluctuation of temperature was between 25.4$\pm$0.3$^{\circ}C$ and that of relative humidity was 50.2$\pm$0.6$\%$ under the airflow rate of 167 mL/min. The emission tests from building materials resulted in TVOC emission rates of 0.011 $\~$ 3.108 mg/m$^{2}$h after 7 days. The general wall-papers emitted toluene abundantly and the natural wall-papers mainly emitted n-butanol and a minor amount of alkanes compound such as n -tetradecane. The remainder consisted of toluene, m,p -xylene, and styrene. The paints mainly emitted toluene and the adhesives mainly emitted chloroform as well as toluene. As a result, this study is expected to suggest meaningful data for future studies in exposure control through selecting healthy building materials and for the establishment of guidelines for various building materials in Korea.

Effects of Concrete and Wood Building Environments on Pregnant Dams and Embryo-Fetal Development in Rats

  • Shin, In-Sik;Kim, Sung-Hwan;Lim, Jeong-Hyeon;Lee, Jong-Chan;Park, Na-Hyeong;Shin, Dong-Ho;Moon, Chang-Jong;Kim, Sung-Ho;Kim, Jong-Choon
    • Toxicological Research
    • /
    • v.25 no.4
    • /
    • pp.209-216
    • /
    • 2009
  • We have recently reported that the continuous exposure of rats to a concrete building environment under cool temperatures had adverse effects on general health parameters and embryo-fetal development. This study examined to compare the potential effects of concrete and wood building environments on pregnant dams and embryo-fetal development in rats. Groups of 10 mated females were exposed to polycarbonate (control), concrete, or wood cages from gestational days (GD) 0 to 20 under cool temperatures $(11.9\sim12.3^{\circ}C)$. All the females underwent a caesarean section on GD 20, and their fetuses were examined for any morphological abnormalities. The temperatures in the cages were similar in all groups but the relative humidity in the concrete and wood groups were higher than in the control group. The concentration of volatile organic compounds in the wood group was higher than in the control group. In the concrete group, maternal effects manifested as an increase in the incidence of clinical signs, a lower body weight, and a decrease in the thymus and ovary weights. Developmental effects included increased post-implantation loss and decreased litter size. Infrared thermal analysis showed that the skin temperature of the rats in the concrete group was lower than that in the control group. In contrast, there were no exposure-related adverse effects on the maternal and developmental parameters in the wood group. Overall, the exposure of pregnant rats to a concrete building environment under cool temperatures has adverse effects on the clinical signs, body weight, skin temperature, organ weight, and embryo-fetal development. On the other hand, exposure to a wood building environment does not have any adverse effects in rats.

Risk Assessment of Volatile Organic Compounds (VOCs) and Formaldehyde in Korean Public Facilities: Derivation of Health Protection Criteria Levels

  • Kim, Ho-Hyun;Lim, Young-Wook;Shin, Dong-Chun;Sohn, Jong-Ryeul;Yang, Ji-Yeon
    • Asian Journal of Atmospheric Environment
    • /
    • v.5 no.2
    • /
    • pp.121-133
    • /
    • 2011
  • This study suggests criteria to conduct a risk assessment of VOCs and formaldehyde in uncontrolled public facilities. Pollutants and facilities were selected based on two years of monitoring data and exposure scenarios in 573 uncontrolled public facilities, composed of 10 types of public institutions. With the exception of social welfare facilities, lifetime ECRs of formaldehyde and benzene in each facility were higher in employees than in users, except in social welfare facilities. In social welfare facilities, the risk of benzene for users ($1{\times}10^{-5}$) was higher than that of workers ($1{\times}10^{-6}$) because facility users live in the facility 24 hours per day, compared to workers who spend an average of 8 hours per day in the facility. The risk of benzene to workers in restaurants, academies, performance halls, internet cafe and pubs were estimated as high as $1{\times}10^{-4}$ and the risk to workers in the theaters and karaoke bars were recorded as $1{\times}10^{-5}$. Because lifetime ECRs of carcinogens exceeded $1{\times}10^{-4}$ for workers and users in most facilities, risk management of formaldehyde and benzene in these facilities is necessary. Although HQs of toluene and xylenes did not exceed 1.0, their HQs did exceed 0.1 in some facilities, so they were evaluated as potentially harmful materials. Additionally, criteria for health protection in IAQ by facility are suggested at $60-100\;{\mu}g/m^3$ for formaldehyde, $400-500\;{\mu}g/m^3$ for TVOCs, $10-20\;{\mu}g/m^3$ for benzene, $150-170\;{\mu}g/m^3$ for toluene and $100\;{\mu}g/m^3$ for xylenes, based on the survey on IAQ and HRA methodology. The excess rates of IAQ to health protection criteria in all facilities were 16% for formaldehyde, 8% for TVOCs and benzene, 9% for toulene, and 5% for xylenes.

Diurnal Variations of O3 and NO2 Concentrations in an Urban Park in Summer: Effects of Air Temperature and Wind Speed (여름철 도심 공원의 O3과 NO2 농도의 일변화: 기온과 풍속의 영향)

  • Han, Beom-Soon;Kwak, Kyung-Hwan;Baik, Jong-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.5
    • /
    • pp.536-546
    • /
    • 2016
  • The diurnal variations of $O_3$ and $NO_2$ in an urban park and the effects of air temperature and wind speed on the diurnal variations are investigated. $O_3$ and $NO_2$ concentrations were observed at a site in an urban park of Seoul from 27 July 2015 to 9 August 2015. The $O_3$ and $NO_2$ concentrations observed in the urban park are compared to those observed at the Gangnam air quality monitoring station (AQMS). The $O_3$ concentration is higher in the urban park than at the Gangnam AQMS in the daytime because the amount of $O_3$ dissociated by NO is smaller as well as partly because the amount of $O_3$ produced in the oxidation process of biogenic volatile organic compounds (VOCs) is larger in the urban park than at the Gangnam AQMS. The $NO_2$ concentration is lower in the urban park than at the Gangnam AQMS during day and night because the observation site in the urban park is relatively far from roads where $NO_x$ is freshly emitted from vehicles. The difference in $NO_2$ concentration is larger in the daytime than in the nighttime. To examine the effects of air temperature and wind speed on the diurnal variations of $O_3$ and $NO_2$, the observed $O_3$ and $NO_2$ concentrations are classified into high or low air temperature and high or low wind speed days. The high $O_3$ and $NO_2$ concentrations in the daytime appear for the high air temperature and low wind speed days. This is because the daytime photochemical processes are favorable when the air temperature is high and the wind speed is low. The scatter plots of the daytime maximum $O_3$ and minimum $NO_2$ concentrations versus the daytime averages of air temperature and wind speed show that the daytime maximum $O_3$ and minimum $NO_2$ concentrations tend to increase as the air temperature increases or the wind speed decreases. The daytime maximum $O_3$ concentration is more sensitive to the changes in air temperature and wind speed in the urban park than at the Gangnam AQMS.

Studies on Flavor Components of Commerical Korean Green Tea (한국산시판녹차(韓國産市販綠茶)의 향기성분(香氣成分)에 관(關)한 연구(硏究))

  • Choi, Sung-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.98-101
    • /
    • 1991
  • To investigate the aroma difference of commercial Korean green tea caused by manufacturing process and harvesting time, analysis of aroma concentrates of steamed green teas(1st tea, 2nd tea) and parched green teas(1st tea, 2nd tea) was accomplished. Steamed green tea, which had a briskness, greenish odor and sweet-floral odor, contained large amounts of terpene alcohols such as linalool, nerolidol, ketones such as cis-jasmone, 2,6,6-trimethyl-2-hydroxycyclohexanone and indole, Parched green tea, which had a slightly greenish odor and floral, roast odor, contained large amounts of terpene alcohols such as linalool, geraniol, aromatic alcohols such as benzylalcohol, phenylethanol and phenol, indole. Almost same tendency of odor component change of 1st tea and 2nd tea differed to harvesting time being observed in steamed tea and parched tea. In 2nd tea of both samples, aliphatic alcohols such as 1-penten-3-ol, cis-2-penten-1-al and two 2, 4-heptadienal(cis, trans and trans, trans) increased remarkably. It seems that these four components effects on the grade of the odor.

  • PDF

Changes in Flavor Compounds of Polygonatum odoratum Root during Roasting (볶음처리에 따른 둥굴레 근경의 향기성분 변화)

  • Park, Nan-Young;Jeong, Yong-Jin;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.1
    • /
    • pp.99-103
    • /
    • 2007
  • In order to evaluate innate flavor during the roasting process, the components responsible for the aroma of unroasted Polygonatum odoratum root and the volatile odor components released during the roasting process were evaluated using the solid phase-microextraction (SPME) headspace method. The raw P. odoratum root contained aldehyde, alcohol, hydrocarbon and acid components, which gave it a grass-like smell. 2-Methylpyrazine was not revealed from the roasted P. odoratum root at $110^{\circ}C$ and $130^{\circ}C$, but was extracted at $150^{\circ}C$. The 2,5-dimethylpyrazine component was the greatest at $130^{\circ}C$. The hexanal component was greater when the root was roasted at $110^{\circ}C$, compared with those at $130^{\circ}C$ and $150^{\circ}C$. The production of 2-acetyl-1-pyrroline component was the greatest when it was roasted at $130^{\circ}C$. Quantitative descriptive analysis of P. odoratum after roasting revealed a high concentration of 2,5-dimethylpyrazine at $130^{\circ}C$ and $150^{\circ}C$, but a low concentration at $110^{\circ}C$. Most of the 2-acetyl-1-pyrroline, which significantly affected its smell, was revealed at $130^{\circ}C$.

High Concentrated Toluene Decomposition by Non-thermal Plasma-Photocatalytic (Mn-Ti-MCM-41) Hybrid System (상온 방전 플라즈마-광촉매(Mn-Ti-MCM-41) 복합 시스템에 놓인 고농도 톨루엔의 분해성능)

  • Ban, Ji-Young;Son, Yeon-Hee;Lee, Sung-Chul;Kang, Misook;Choung, Suk-Jin;Sung, Joon-Yong
    • Applied Chemistry for Engineering
    • /
    • v.16 no.3
    • /
    • pp.413-421
    • /
    • 2005
  • This study focused on the decomposition of toluene in a plasma-photocatalytic hybrid system. Hexagonally packed meso-structured Mn-titanosilicates (Mn-Ti-MCM-41), as the photocatalysts, have been prepared by the hydrothermal method. The physical properties of the photocatalysts were characterized using XRD, XPS, TEM, BET/ICP, and $NH_3$/Toluene-TPD. Experiments were carried out at the applied voltage of 9.0 kV and at room temperature of $20^{\circ}C$. In the plasma only system, the activity of the toluene decomposition was higher than that in the photocatalytic system. However, the amount of by-products, such as phenol, $C_2{\sim}C_4$ alkene, was also increased in the plasma only system. However, the by-products decreased remarkably in a plasma-photocatalytic hybrid system. When Mn5mol%-Ti-MCM-41 was used as a photocatalyst in a plasma-photocatalytic hybrid system, the $CO_2$ selectivity in products was increased dramatically compared to other catalysts. It was confirmed that a plasma-photocatalytic hybrid system was better for toluene decomposition compared to photocatalytic and plasma only systems.