• 제목/요약/키워드: water index

검색결과 4,066건 처리시간 0.031초

맛있는 물 지표 개발을 통한 국내 약수 평가 (Assessment of Korean spring waters using a new mineral water index)

  • 이승재;이상은;김종곤;박희경
    • 상하수도학회지
    • /
    • 제25권1호
    • /
    • pp.7-14
    • /
    • 2011
  • This study was motivated by the purpose of improving the O-Index, currently used to quantify water tasty. The authors first develop the M-Index after normalizing Ca, K, and $SiO_{2}$ concentrations in the spring water, in that the concentrations are subject to their log-normal distributions. The M-Index is then compared with the O-Index based on the results of sensory tests, revealing that sensory tests are correlated with the M-Index much more than the O-Index. Furthermore, the developed index is applied to evaluate water sampled from 53 springs in Korea. It is concluded that water, sampled from five most famous springs, has high values in M-Index. In addition, water, collected from springs that are relatively accessible, contains low values, and thus is expected not to tasty good.

한국의 저서동물 하천하상지수(BMSI) 개선을 위한 수질요인 분석 (Analysis of Water Quality Factors for Benthic Macroinvertebrates Streambed Index (BMSI) Improvement in Korea)

  • 김동희;공동수
    • 한국물환경학회지
    • /
    • 제35권6호
    • /
    • pp.539-549
    • /
    • 2019
  • In 2016, Benthic Macroinvertebrates Streambed Index (BMSI) was proposed as an index to evaluate streams as benthic macroinvertebrate depending on the substrate type of streambed. However, orignal BMSI were selected without consideration of water quality. Analyzes without water quality do not constitute biological indices based solely on the substrate type of streambed. Therefore, in this study, the indicator value was improvement in consideration of water quality, and the distribution characteristics of benthic macroinvertebrates according to the substrate type of streambed were analyzed under relatively equal water quality conditions. We surveyed 20,155 sampling units in Korea from 2008 to 2018, and we re-estimated each lithophility of 191 taxa. As a result of estimating the streambed of each newly lithophilic value classification group considering the water quality, it was different from the original lithophilic value. Representative integer lithophilic values were newly calculated from 126 taxa among the 191 index taxa used in the analysis. The correlation between new constructed BMSI and community structure was compared and analyzed. It showed extreamely significance (p<0.001) in the dominance index, diversity index, abundance index, and evenness index of the community structure. Diversity index, abundance index, and evenness index showed positive correlation, and dominance index showed negative correlation. The correlation coefficient (r) was the highest in the richness index of about 0.664.

식수의 수질중 미네랄성분과 음이온을 이용한 지수에 관한 연구 (Study on the Drinking Water Index with Minerals and Anions)

  • 김형석;신현덕;이기태
    • 환경위생공학
    • /
    • 제8권2호
    • /
    • pp.99-108
    • /
    • 1993
  • It is well known that we should take 2L of drinking water per day to maintain our health. The drinking water quality is becoming worse owing to sewage discharge and industrial wastewater. Surface water is polluted by various kinds of contaminants and ground water were known as clean and unpolluted water, but through recent many reports the ground waters are also contaminated by waste disposal and intrusion of organic and bacterial movement. This research was undertaken to make a water index of water contamination by referringcations cations and anions. NH$_{4}$, Fe, Mn, and Pb are chosen as cations and $NO_3$, Cl, and $SO_4$ ions are chosen as anions to make a index, and the following water index was made as the contamination index. (Fe+Mn+Pb)/0.7+$(NH_4+NO_3+Cl+SO_4)$/10.5<6.0 By using ton Chromatography the cations and anions are rapidly analyzed and plotting the analyzed data to the equation, we can easily get the degree of contaminations by avoiding analysis of over 37 water parameters in several days. Of course this index of water contamination is not perfect and detail one, but in case of emergent case or to know the overall trends of contamination, it is convenient to use this index. Among the tested 5 kinds of samples the ground water showed contamination index of 6.87. Authors used the already published healthy index and tasty index and differentiated their degrees in detail.

  • PDF

국내 수질에 적합한 부식성지수 선정 연구 (Evaluation of Corrosion Index by Water Quality Parameters in Korea)

  • 안경희;유순주;박수정;권오상
    • 한국물환경학회지
    • /
    • 제28권4호
    • /
    • pp.615-623
    • /
    • 2012
  • In this study, we evaluate the corrosion indexes (CI) such as Langelier Index (LI), Larson ratio (LR), Ryznar saturation index (RSI), Aggressiveness index (AI) of water quality for raw water, treated water and water in distribution reservoir at major eight drinking water treatment plants (DWTPs) in Korea. By analyzing secondary contamination of tap water, the variation of secondary contaminants was investigated with regard to pipe materials, aging and corrosion index (CI). In addition, we suggested an appropriate CI applicable water quality and the management plan for CI monitoriing. All CI showed corrosive water quality, and they did not change significantly in the distribution network. However, Copper (Cu), iron (Fe) and zinc (Zn) concentrations as secondary contaminants increased through the distribution network. Among CI, LI was most sensitive to changes in raw water quality and drinking water treatment. Also, it has high correlations with other indexes such as RSI, AI. Therefore, LI is considered as an appropriate CI to the domestic water quality. Based on these result, we propose LI as a drinking water quality standard to control the pipe corrosion from DWTPs.

IMPLEMENTATION OF GIS BASED WATER QUALITY INDICES FOR WATER QUALITY MANAGEMENT

  • Song, Ta-O;Kim, Kye-Hyun
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.612-615
    • /
    • 2007
  • Water quality modelling is an ideal tool of simulating physical, chemical and biological changes occurring in water systems. It has been utilized in a number of GIS-based water quality management and analysis applications. However, there is a need of a decision making process to translate the modelling result into an understandable form thereby implement the modelling results to the real world. This paper outlines a new water quality index called the QUAL2E's water quality index (QWQI) based on the water quality modelling using QUAL2E. The development mainly includes four steps: variable selection, sub-index development, weight assignment and sub-index aggregation. An experiment of applying the index and GIS to the Sapgyo River in Korea was implemented. Different from other water quality indices for general water uses, the index is specifically used for the simulated water quality indicators. The index can provide a simple and easy-to-understand decision support. Furthermore, interfacing with GIS, the decision analysis can be performed within a spatial environment. However, more study needs to be made in the future including the improvement of aggregation function.

  • PDF

통합수자원평가지수의 개발 (Development of Integrated Water Resources Evaluation Index)

  • 이동률;최시중;문장원
    • 한국수자원학회논문집
    • /
    • 제46권10호
    • /
    • pp.1017-1028
    • /
    • 2013
  • 본 연구의 목적은 물이용, 홍수 및 하천환경의 3개 수자원 정책 부문에서 수행한 사업성과를 지역별로 평가할 수 있는 통합수자원평가지수(Integrated Water Resources Evaluation Index, IWREI)를 개발하는 것이다. IWREI는 각 부문별 취약성을 나타내는 물이용취약지수(Water Use Vulnerability Index, WUVI), 홍수취약성지수(Flood Vulnerability Index, FVI), 하천환경취약지수(River Environment Vulnerability Index, REVI)를 통합하여 산정된다. 이들 지수들은 물이용, 홍수, 하천환경의 피해를 주는 압력지표(pressure indicators)와 이에 의한 피해 현상지표(state indicators) 및 피해의 대책지표(response indicators)에서 선정한 총 26개 지표로 구성된다, 산정된 지수는 Low, Medium Low, Medium, Medium High, 및 High의 5단계로 취약성 및 정책수행의 효과를 나타냈다. 우리나라 115개의 중권역에 대해 WUVI, FVI, REVI 및IWREI을 분석한 결과, 1990년대 초반에 비해 2000년대 초반의 지수가 개선되어 수자원 정책의 사업효과를 확인할 수 있다. 본 연구에서 개발된 지역간수자원의 취약지수와 평가지수는 수자원 정책목표의 설정과 사업이행의 우선지역을 선정하는데 이용할 수 있다.

원·정수의 부식특성에 따른 상수관망에서의 부식성 수질 모니터링 (The Monitoring of Corrosive Water Quality in Water Distribution System by Corrosion Characteristics of Raw and Tap water)

  • 배석문;김도환;손희종;최동훈;김익성;김경아
    • 한국환경과학회지
    • /
    • 제24권7호
    • /
    • pp.907-915
    • /
    • 2015
  • The tap water is generally known to be corrosive in the pH range at 6.5 ~ 7.5. And the degree of corrosion varies depending on the types of raw water such as river surface water or lake water of the dam. Although several corrosion index represents the corrosivity of tap water, the typical corrosion indexes such as Langelier saturation index (LI) and calcium carbonate precipitation potential (CCPP) were calculated to monitoring the corrosive water quality about raw and tap water in water distribution system. To control the corrosive water quality, the correlation between corrosion index and water quality factors were examined. In this study, corrosion index (LI, CCPP) and the pH was found to be most highly correlated.

오염물질의 특성이 막오염 지수에 미치는 영향 (Effect of Foulant Characteristics on Membrane Fouling Index)

  • 박찬혁;김하나;홍승관
    • 상하수도학회지
    • /
    • 제19권6호
    • /
    • pp.775-780
    • /
    • 2005
  • This study was performed to investigate the effect of foulant characteristics on Membrane fouling index such as Silt Density Index (SDI) and Modified Fouling Index (MFI). A linear relationship was found relating the fouling index (both SDI and MFI) on particle concentration, but fouling index values were nonlinearly (exponentially) with increasing organic concentration. When organic matter was the primary cause of fouling, the MFI was not accurately predicted due to internal fouling such as pore adsorption. The fouling index was determined mainly by particle characteristics when both particle and organic coexisted in the feed water. This observation was attributed to lessening of organic pore adsorption by particle cake layer formed on the membrane surface. Bench-scale actual fouling experiments demonstrated that permeate flux declines much faster with feed water containing particles than organic matters although fouling potential predicted by SDI values were identical, indicating that the accurate prediction of fouling potential requires the development of fouling index reflecting different foulant characteristics.

Happel Cell 모델을 이용한 막오염 지수 예측 (Prediction of Membrane Fouling Index by Using Happel Cell Model)

  • 박찬혁;김하나;홍승관
    • 상하수도학회지
    • /
    • 제19권5호
    • /
    • pp.632-638
    • /
    • 2005
  • Membrane fouling index such as Silt Density Index (SDI) and Modified Fouling Index (MFI) is an important parameter in design of the integrated RO/NF membrane processes for drinking water treatment. In this study, the effect of particle, membrane and feed water characteristics on membrane fouling index were investigated systematically. Higher fouling index values were observed when filtering suspensions with smaller particle size and higher feed particle concentration. Larger membrane resistance due to smaller pore size resulted in an increased membrane fouling index. The variations of feed water hardness and TDS concentrations did not show any impact on fouling index, suggesting that there were no significant colloidal interactions among particles and thus the porosity of particle cake layer accumulated on the membrane surface could be assumed to be 0.36 according to random packing density. Based on the experimental observations, fundamental membrane fouling index model was developed using Happel Cell. The effect of primary model parameters including particle size ($a_p$), particle concentration ($C_o$), membrane resistance ($R_m$), were accurately assessed without any fitting parameters, and the prediction of membrane fouling index such as MFI exhibited very good agreement with the experimental results.

수돗물 수질에 따른 옥내급수관 부식에 미치는 영향분석 (The Corrosion Effect of the Water Pipelines in Buildings according to Drinking Water Quality)

  • 유순주;박수정;안경희;김현구;김창수;정일록;박영복
    • 한국물환경학회지
    • /
    • 제24권6호
    • /
    • pp.701-708
    • /
    • 2008
  • As a countermeasure for reduction of corrosion in the delivery and distribution pipes used for tap water, materials for the pipelines in-houses and the effect of water quality on corrosivity of water pipelines were investigated in the distribution system of Han river. As the corrosion index at 6 water purification facilities of Han river, average Langelier Saturation Index (LI) of raw and finished water were -1.0 and -1.4 respectively and average Larson Index (LR) were 9.5 and 9.9, respectively. And also corrosion potential showed corrosivity in finished water (-431~-462 mV) as well as raw water (-426~-447 mV). This results indicate that tap water quality of han river have corrosivity. To understand the corrosivity effect in pipe material used for premise distribution system, water quality of stagnant tap water and tap water were analyzed and the differences between them were calculated. The difference concentration of iron, copper and zinc were $12.9{\mu}g/L$, $31.0{\mu}g/L$ and $45.0{\mu}g/L$ respectively in galvanized steel pipe for use more than 15 years and showed highest concentration. As a result, the control to corrosivity in the water pipelines, corrosivity control treatment in the water purification system can be applied. In advance it is necessary to monitor corrosivity of water quality using corrosive index because corrosivity may differ from the seasonal and regional characteristics and water chemicals dosage. For the future the guideline for corrosion index have to be established.