• Title/Summary/Keyword: window size

Search Result 815, Processing Time 0.032 seconds

Characterization of Particle Size Distribution of Infiltrated Secondhand Smoke through the Gap in a Single Glazed and a Secondary Glazed Window by Indoor and Outdoor Pressure Differences (실내외 압력 차에 따른 단창과 이중창의 틈새로 침투된 간접흡연의 입자 크기 분포 특성)

  • Kim, Jeonghoon;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.4
    • /
    • pp.360-369
    • /
    • 2018
  • Objectives: Outdoor tobacco smoke can penetrate into the indoor environment through cracks in the building envelope. This study aimed to characterize the particle size distribution of infiltrated secondhand smoke (SHS) through the gap in a single glazed and a secondary glazed window according to pressure differences in a chamber. Methods: Two polyvinyl chloride sliding windows were evaluated for infiltration, one with a glazed window and the other with a secondary glazed window. Each window was mounted and sealed in a polycarbonate chamber. The air in the chamber was discharged to the outside to establish pressure differences in the chamber (${\Delta}P$). Outdoor smoking sources were simulated at a one-meter distance from the window side of the chamber. The particle size distribution of the infiltrated SHS was measured in the chamber using a portable aerosol spectrometer. The particle size distribution of SHS inside the chamber was normalized by the outdoor peak for fine particles. Results: The particle size distribution of SHS inside the chamber was similar regardless of window type and ${\Delta}P$. It peaked at $0.2-0.3{\mu}m$. Increases in particulate matter (PM) concentrations from SHS infiltration were higher with the glazed window than with the secondary glazed window. PM concentrations of less than $1{\mu}m$ increased as ${\Delta}P$ was increased inside the chamber. Conclusions: The majority of infiltrated SHS particles through window gap was $0.2-0.3{\mu}m$ in size. Outdoor SHS particles infiltrated more with a glazed window than with a secondary glazed window. Particle sizes of less than $1{\mu}m$ were associated with ${\Delta}P$. These findings can be a reference for further research on the measurement of infiltrated SHS in buildings.

A Comparative Analysys of Window Energy Performance According to the Difference Between Actual size and Standard size (창호의 성능인증 규격 기준과 면적 변화에 따른 에너지성능 비교분석)

  • Kim, Seong-Beom;Lee, Su-Yeul;Kim, Dong-Yoon;Choi, Won-Ki
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.1
    • /
    • pp.49-60
    • /
    • 2020
  • This study reviewed selected specific windows and reviewed the window performance certification criteria including KS F 2278 and KS L 9107 and analyzed the change in performance based on the change of area. This study also compared the heating and cooling loads of an apartment house applied with window performance reviewed in consideration of insulation and SHGC performance and actual size based on KS F 2278. The analyzed window was a double window composed of aluminum and PVC and the building was the apartment house model of 141 ㎡. The analysis results were as follows. First, as the window glass's thermal performance is superior to frame, the performance degraded in reduced area. In case of selected window, the 1 m × 1m window's thermal performance and SHGC decreased by 35% and 37% respectively compared to 2 m × 2 m window. Secondly, in the comparison of performance for increasing area with 2 m × 2 m and 3 m × 3 m windows, the 3 m × 3 m window's thermal performance and SHCG increased about 14%. Third, in the comparison of heating and cooling loads of the analyzed model considering the apartment house model applied with window performance derived from KS F 2278 and actual figures, the model's total heating and cooling loads increased by 33% with cooling decreasing by 36% and heating increasing by 77%. Above analysis results show that evaluation of window performance based on criteria such as KS F 2278 and KS L 9107 may lead to distortion of performances different from actual products. Thus, it is necessary to suggest new evaluation criteria.

Improving a Internal Network Performance By Controlling Window Size (윈도우 사이즈 조절을 통한 내부 네트워크의 성능향상)

  • Jeon, Chul-Wan;Kwon, Kyung-Hee
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2003.05b
    • /
    • pp.1189-1192
    • /
    • 2003
  • 본 연구는 어떤 조직 내에서의 네트워크를 내부 네트워크와 외부 네트워크로 구분하고, 이들에 각각의 서버를 할당하여 분산된 서비스를 제공하는 환경을 대상으로 한다. 각 서버의 특성에 맞게 TCP Parameter 중의 하나인 Window Size를 설정하여 내부 네트워크의 성능 향상을 시도하였다. 외부 네트워크에서는 Window Size 가 큰 영향을 미치지 못하나 내부 네트워크에서는 Window Size 에 따라서 처리율(Throughput)이 크게 달라진다. 본 연구에서는 Window Size 의 조절을 통해서 내부 네트워크의 처리율(throughput) 변화를 NS-2 를 사용하여 시뮬레이션 해 보고 그 결과를 비교하여 내부 네트워크의 성능 향상을 확인하고자 한다.

  • PDF

Comparison of Savitzky-Golay filtering results for quality control of soil moisture data (토양수분량 자료의 품질관리를 위한 Savitzky-Golay 필터링 적용결과 비교)

  • Lee, Yongjun;Kim, Kiyoung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.268-268
    • /
    • 2020
  • 토양수분량은 수문연구에 있어 중요한 인자 중의 하나이며, 그 필요성이 점차 강조되고 있다. 국내에서도 최근 새로운 관측기기의 도입이나 수자원위성의 개발 등에 관한 연구가 점차 활발하게 이뤄지고 있으나, 토양수분량 자료의 생산, 품질관리 및 배포 시스템에 관한 연구 및 개발이 부족한 실정이다. 반면에 해외에서는 International Soil Moisture Network(ISMN)을 통해 토양수분량 자료의 품질관리 및 배포가 활발하게 이루어지고 있는데, ISMN에서는 토양특성, 강우에 대한 반응, 토양온도, 시계열특성을 이용해 토양수분량 관측 자료를 품질관리 하고 있다. 본 연구에서는 ISMN의 spike 검출 알고리즘에서 그래프 평활화(smoothing)를 위해 이용되는 Savitzky-Golay 필터의 window size와 polynomial order(filter order)를 다양하게 변화시키고, 이를 설마천 관측소에서 측정한 토양수분량 원시자료에 적용하여 window size와 polynomial order별로 편의(bias), 변동(variation), 평균 제곱근 오차(Root Mean Square Error, RMSE)를 산정하였다. 통계산정 결과 원시자료와의 bias는 window size가 3이고 polynomial order가 2인 필터를 적용했을 때 가장 작은 것으로 나타났으며, variance는 window size가 3이고 polynomial order가 2인 필터를 이용했을 때가 원시자료와 가장 유사한 것으로 나타났다. 또한, RMSE는 window size가 5이고 polynomial order가 3일 때 가장 작은 것으로 나타났다. 이는 추후 토양수분량 품질관리를 수행하기 위해 적절한 필터 계수 값을 제시할 수 있는 논문으로 사료된다.

  • PDF

Dynamic Adjustment of Ad hoc Traffic Indication Map(ATIM) window to save Power in IEEE 802.11 DCF

  • Nam, Jae-Hyun
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.3
    • /
    • pp.343-347
    • /
    • 2008
  • Wakeup schemes that turn off sensors' radio when communication is not necessary have great potential in energy saving. At the start of each beacon interval in the IEEE 802.11 power saving mode specified for DCF, each node periodically wakes up for duration called the ATIM Window. However, in the power saving mechanism specified in IEEE 802.11, all nodes use the same ATIM window size. Since the ATIM window size critically affects throughput and energy consumption, a fixed ATIM window does not perform well in all situations. This paper proposes an adaptive mechanism to dynamically choose an ATIM window size according to network condition. Simulation results show that the proposed scheme outperforms the IEEE 802.11 power saving mechanism in terms of the amount of power consumed and the packet delivery ratio.

The optimal window system of office buildings considering energy efficiency (에너지 효율로 본 상업용 건물의 적정 창호에 관한 연구)

  • Yoo, Ho-Chun;Oh, Young-Ho;Park, Seung-Kil
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.4
    • /
    • pp.53-60
    • /
    • 2005
  • The purpose of this study is to improve energy efficiency of windows in office buildings through the evaluation of their heating, cooling and illumination load. Energy efficiency is influenced by window size which is determined at the early stage of building design. The process of this study is as follows. First, energy performance is analysed according to the various rates of windows through computer simulation (ECOTECT). Then, the annual heating, cooling and illuminating loads according to the different window sizes are compared one another. Results indicated that the optimal window size considering energy efficiency is 50% of the surface area. When the window size is 50% of the surface area, annual maintenance expense is also smallest. Since the cost of cooling is larger than that of heating, too low indoor air temperature in summer is unfavorable based on the reasonable annual maintenance expenses.

The verification about possibility of introducing Window to Floor Ratio as design index for building energy performance

  • Choi, Won-Ki;Lee, Yong-Jun;Lee, Hyun-Soo;Eom, Jae-Yong;Lee, Chung-Kook
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.23-28
    • /
    • 2017
  • Purpose: Many design index that are using in planning phase have been developed. The most popular things among them are Window to Wall Ratio and Surface to Volume Ratio. However there are some limits. Window to Wall Ratio cannot consider building size and Surface to Volume Ratio cannot do Window to Wall Ratio. Accordingly, in this paper, the Window to Floor Ratio was proposed that it can be considered both building size and Window to Wall Ratio. And analyzed correlation of energy demand. Method: For the test, 16 modules with the size of $6m{\times}6m{\times}4m$ were used to make 35 models with the same volume. The simulation was conducted to 945 cases using the window-to-wall ratio of 30, 50 and 70 % in three areas such as Seoul, Gwangju and Jeju and three kinds of windows. And IES_VE was used. Result: The findings above show that the Window to Floor Ratio that can be considered both building size and Window area have to become as design index. It was found out that design criteria with SHGC is necessary, not with the thermal performance (U-value). It is needed to additional analysis about residential building and the effect of 24-hours heating and cooling condition. It plans to carry out research to establish design indicators for climatic conditions in the country and building applications.

Optimizing the maximum reported cluster size for normal-based spatial scan statistics

  • Yoo, Haerin;Jung, Inkyung
    • Communications for Statistical Applications and Methods
    • /
    • v.25 no.4
    • /
    • pp.373-383
    • /
    • 2018
  • The spatial scan statistic is a widely used method to detect spatial clusters. The method imposes a large number of scanning windows with pre-defined shapes and varying sizes on the entire study region. The likelihood ratio test statistic comparing inside versus outside each window is then calculated and the window with the maximum value of test statistic becomes the most likely cluster. The results of cluster detection respond sensitively to the shape and the maximum size of scanning windows. The shape of scanning window has been extensively studied; however, there has been relatively little attention on the maximum scanning window size (MSWS) or maximum reported cluster size (MRCS). The Gini coefficient has recently been proposed by Han et al. (International Journal of Health Geographics, 15, 27, 2016) as a powerful tool to determine the optimal value of MRCS for the Poisson-based spatial scan statistic. In this paper, we apply the Gini coefficient to normal-based spatial scan statistics. Through a simulation study, we evaluate the performance of the proposed method. We illustrate the method using a real data example of female colorectal cancer incidence rates in South Korea for the year 2009.

Decision of Maximum Congestion Window Size for TCP Performance Improvement by Bandwidth and RTT Measurement in Wireless Multi-Hop Networks

  • Huh, In;Lee, Jae-Yong;Kim, Byung-Chul
    • Journal of Information Processing Systems
    • /
    • v.2 no.1
    • /
    • pp.34-38
    • /
    • 2006
  • In the wireless network, TCP performs poorly because it was originally designed for wired networks and does not take into consideration wireless characteristics such as mobility, high-loss probability, and hidden-terminal problems. In particular, in the wireless multi-hop networks, a large congestion window increases the probability of contention and packet losses, and TCP performance is degraded severely as a result. So, it is necessary to limit the TCP congestion window size in order keep the probability of contention loss in the system to a minimum. In this paper, we propose a new scheme for determining the maximum congestion window size based on the measured bandwidth and Round-Trip-Time (RTT). Using ns-2 simulation, we show that the proposed scheme reduces the probability of packet contention and improves TCP performance.

Performance analysis of changing initial TCP window size (Initial TCP window size의 변경에 따른 성능분석)

  • 김정훈;이계상;김창규
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1998.11a
    • /
    • pp.370-373
    • /
    • 1998
  • 현재 인터넷상의 QoS(Quality of Service) 향상을 위해서 여러 가지 방법과 기술들이 소개되고 있다. 이러한 QoS 향상을 위해 트래픽 제어기법과 IS(Integrated Services), DS(Differentiated Services), Tag Switching, MPLS(Multi protocol Label Switching) 등과 같은 방법으로 인터넷에서 보다 나은 서비스를 지원하려는 노력이 시도되고 있다. 본 논문에서는 특히 TCP connection에서의 initial window size의 변경이 네트워크의 QoS, 즉 link의 utilization과 packet의 drop, performance에 어떠한 영향을 주는지를 살펴본다. 그리고, 이에 대한 특성을 분석하고 개선점을 현재의 인터넷에서 가장 많이 사용되어지고 있는 FTP와 web에 대한 모델을 사용하여 가상적으로 시뮬레이션을 해본다.

  • PDF