Effects of Dielectric Breakdown in XLPE Insulation Cables by Metal Impurities

XLPE 절연케이블내 금속성 불순물이 절연파괴에 미치는 영향

  • Published : 1997.07.21

Abstract

In this work, simultaneous measurement such as change distribution and electrical conduction of maleic anhydride grafted XLPE was investigated. Heterocharge was found in XLPE and it decreased with increasing MAR graft ratio in XLPE-g-MAH. Conduction currents also decreased with increasing MAR graft ratio. The relationship between the space change behavior and the electrical conduction characteristics in XLPE-g-MAH is discussed.

Keywords