NOx removal characteristics by the dielectric packed-bed plasma reactor

Dielectric packed-bed 플라즈마 반응기를 사용한 NOx 제거 특성

  • 김응복 (인천대학교 전기공학과) ;
  • 김동욱 (인천대학교 전기공학과) ;
  • 정영식 (인천대학교 전기공학과)
  • Published : 1999.11.20

Abstract

This paper presents the removal characteristics of nitrogen oxides (NOx) by the dielectric ($Al_{2}O_{3}$) packed-bed plasma reactor. Reactor packed with 5-mm diameter $Al_{2}O_{3}$ beads, and was designed to remove NOx at atmospheric pressures from the moving pollution source such as diesel automobile. The experiments were conducted for applied voltages from 5 to 10kV, flue gas rate from 2 to 5L/min, and frequency from 0.5 to 2kHz. The NOx removal efficiency significantly increased with increasing applied voltage. Especially removal rate significantly increased with increasing frequency. However, in this experiment discharge power was relatively high.

Keywords