Design of Flux Barrier type Synchronous Reluctance Motor to improve Saliency Ratio

토크비 개선을 위한 자속 장벽형 회전자 구조 동기 릴릭턴스 전동기의 설계

  • Published : 2000.07.17

Abstract

It is demonstrated that the torque performance of the flux barrier type synchronous reluctance motor(SynRM) can be improved in terms of geometric parameters. Torque ana power factor are related to the difference of inductances and the saliency ratio. And these inductance characteristics are determined by the geometric parameters of rotor: the number of layers. the width of iron to the width of flux barrier($K_w$). slot number and shape, airgap, bridge, etc. The relationship between geometric parameters. especially, $K_w$ and motor performance will be studied. This paper shows that torque and power factor are improved through redesign with considering geometric parameters. Performance comparisons of proto type SynRM and improved SynRM are given by FEA(Finite Element Analysis).

Keywords