The errors and reducing method in the frequency response function from impact hammer testing

충격햄머 가진으로 구한 주파수응답함수의 오차와 해결방법

  • 안세진 (부산대학교 기계설계공학과) ;
  • 정의봉 (부산대학교 기계설계공학부)
  • Published : 2002.05.01

Abstract

The spectrum of impulse response signal which is obtained from an impulse hammer testing is used for frequency response function, nevertheless it has serious faults when the record length for the signal processing is not very long. The faults cannot be avoided with the conventional signal analyzer that is processing all the signals as if they are always periodic. The signals generated by the impact hammer are undoubtedly non-periodic because of the damping, and are acquired for limited recording time due to the memory as well as the computation performance of the signal analyzer. This paper will make clear the relation between the faults and the length of recording time, and propose the way for solving the faults.

Keywords