Comparison of the I-V Characteristic as Various Composition ratio of Iodine in a-Se of $BrO_2/a-Se$ based Radiation Conversion Sensor

$BrO_2/a-Se$ 구조의 방사선 변환센서에서 a-Se에 첨가된 조성비 변화에 따른 I-V 특성 비교

  • Choi, Jang-Yong (Department of Biomedical Engineering, College of Biomedical Science and Engineering, Inje University) ;
  • Park, Ji-Koon (Department of Biomedical Engineering, College of Biomedical Science and Engineering, Inje University) ;
  • Gong, Hyun-Gi (Department of Biomedical Engineering, College of Biomedical Science and Engineering, Inje University) ;
  • Ahn, Sang-Ho (Medical Imaging Research center of Inje University) ;
  • Nam, Sang-Hee (Medical Imaging Research center of Inje University)
  • 최장용 (인제대학교 의생명공학대학 의용공학과) ;
  • 박지군 (인제대학교 의생명공학대학 의용공학과) ;
  • 공현기 (인제대학교 의생명공학대학 의용공학과) ;
  • 안상호 (인제대학교 의료 영상 연구소) ;
  • 남상희 (인제대학교 의료 영상 연구소)
  • Published : 2002.11.07

Abstract

Present1y the X-Ray diagnosis system is a real condition that is changing by digital ways in it's existent analog ways. This digital radiation detector is divided by the direct method and the indirect method. The indirect method of applied voltage has special qualities that the resolution is low than direct method by diffusion effect that happens. The conversion process ( radiation${\rightarrow}$visible ray${\rightarrow}$electrical signal of two times, has shortcomings that the energy conversion efficiency of electrical signal is low. The direct method has shortcomings that need strong electric fie1d to detect electrical signal efficiently. This research achieved to develop digital detector of the Hybrid method that have form that mixes two ways to supplement shortcoming of direct. indirect method. A studied electrical characteristic by Iodine's Mixture ratio change is added to selenium in the detector which has a multi-layer structure (Oxybromide + a-Se). There are 8 kinds of Manufactured compositions to amorphous selenium Iodine each 30ppm, 100ppm, 200 ppm, 300ppm, 400ppm, 500ppm, 600ppm, 700ppm by a doped photoconductor through a vacuum thermal evaporation method. The phosphor layer is consisted of Oxybromide ($BrO_2$) which uses optical adhesives multi-layer structure. The manufactured compositions calculates and compares Net Charge and signal to noise ratio measuring Photocurrent about Darkcurrent and X-ray. When doped Iodine Mixture ratio is 500ppm to the multi-layer structure (Oxybromide + a-Se), applied voltage of $3V/{\mu}m$, leakage current of compositions $2.61nA/cm^2$ and net charge value by 764pC/$cm^2$/mR then the best result appeared.

Keywords