Effect of Secondary Air Injection on CO and NOx Emission in an Internally Circulating Fluidized Bed Combustor

이중 순환식 유동층 연소로내에서 2차 공기 주입에 의한 CO, NOx 저감효과

  • 장석돈 (연세대학교 기계공학과) ;
  • 신동훈 (연세대학교 CT(Clean Tech.) 연구단) ;
  • 황정호 (연세대학교 기계공학과)
  • Published : 2002.06.07

Abstract

Combustion experiments are carried out to obtain the fundamental data for application of a internally circulating fluidized bed combustor to the combustion of paper sludge wastes. Experimental parameters are identified as secondary air ratio, sludge weight and water contents. The secondary air ratio was varied from 0 to 20% and water content was 14%, 25%, 35%, 45%, 62% and sludge weight was 30g, 60g, 90g. As a result, carbon conversion ratio was higher than injection of primary air. Emission of CO and NOx reduced with an increase of secondary air injection.