The transient analysis for choosing the optimal SCR ratings of AC3 utilization category testing equipment used for electrical durability test for magnetic switch

IEC60947-4에 따른 전자개폐기 전기적 수명시험설비의 과도현상을 고려한 SCR최적 정격선정에 대한 연구

  • Ryu Haeng Soo (PT&T(Power Testing & Technology Institute), LG industrial Systems Co. Ltd.) ;
  • Kim Kab Dong (PT&T(Power Testing & Technology Institute), LG industrial Systems Co. Ltd.) ;
  • Han Gyu Hwan (PT&T(Power Testing & Technology Institute), LG industrial Systems Co. Ltd.)
  • 류행수 (LG산전 전력시험기술센터) ;
  • 김갑동 (LG산전 전력시험기술센터) ;
  • 한규환 (LG산전 전력시험기술센터)
  • Published : 2004.07.14

Abstract

This paper is the transient analysis for choosing the optimal SCR ratings of AC3 utilization category testing equipment(AC3 TE) used for electrical durability test for magnetic switch according to IEC60947-4 Annex B by utilizing EMTP -ATPDraw. Magnetic contactor closes and opens the motor load with ON/OFF switch of electronic contactor. It is also used for protecting and controlling the load. Magnetic contactor detects the over-current flow in the load with a over-current relay and disconnects the load by opening its control power. The key cost of AC3 TE is the SCR ratings. The more decreases SCR ratings, the more decreased the cost is, but it is impossible to ensure the reliability. On the other hand, the more increases SCR ratings, the more increased the cost is. Thereupon, in this paper after the testing circuit is simulated by using EMTP-ATPDraw the SCR ratings will be applied in order to guarantee the testing reliability of PT&T(Power Testing and Technology institute in LG Industrial Systems Co.,Ltd.).

Keywords