Evaluation of indoor refrigerator noise in steady-state condition

주거 공간내 냉장고 소음의 정상상태 평가

  • Published : 2004.11.01

Abstract

The characteristics of refrigerator noise recorded in anechoic chamber was investigated in condition of a the real living room and a kitchen. To predict the noise propagation in an apartment unit, room acoustic simulation software was used. It was found that the noise level in the real living room was $4\sim8dB$ higher than in the anechoic chamber. When a noise barrier and absorption materials were used on the rear wall and floor, the noise level reduced up to $3\sim4dB$. In addition, when the subjective evaluation of auralized refrigerator noise was undertaken using headphone, it was revealed that 21dB (A) is the allowable sound pressure level of 95% satisfaction.

Keywords