A Study on image noise removal of $2^{nd}$ electron detector for a E-Beam Lithography

전자빔 가공기를 위한 2 차 전자 검출기의 영상 노이즈 제거에 관한 연구

  • Published : 2005.06.01

Abstract

The electron beam machining provides very high resolution up to nanometer scale, hence the E-Beam writing technology is rapidly growing in MEMS and nano-engineering areas. For E-Beam machining, $2^{nd}$ electron detector is required to see a machined sample at the stage. The $2^{nd}$ electron detector is composed of scintillator and photomultiplier with signal amplifier and high voltage power supplier. Since a photomultiplier tube is an extremely high-sensitivity photodetector, the signal light level to be detected is very low and therefore particular care must be exercised in shielding external light. In this paper, the design methodology of $2^{nd}$ electron detector and the image noise removal method are introduced.

Keywords