필터시스템을 이용한 비소처리흡착제의 성능비교분석

  • 방선택 (광주과학기술원, 환경공학과) ;
  • 김주용 (광주과학기술원, 환경공학과) ;
  • 김경웅 (광주과학기술원, 환경공학과)
  • Published : 2005.04.01

Abstract

Laboratory and field experiments were conducted to study the effectiveness of five adsorbents for the removal of arsenic. The adsorbents included activated alumina (AA), iron coated AA (ICAA), and granular ferric hydroxide (GFH), granular ferric oxide (GFO), and granular titanium dioxide (GTD). Laboratory experiments were conducted to investigate arsenic removal using challenge water prepared in accordance with NSF International Standards 53 (ANSl/NSF 53-2001). Field experiments were conducted using arsenic-contaminated groundwater In laboratory experiment, the treatment capacity decreased in the following order GTD > GFO > GFH. In contrast, the treatment capacity decreased in the following order GFO > GTD > GFH > ICAA > Ah in field experiments.

Keywords