Considerations in the reliability improvement against Circulation Current in the Catenary System for Electirc Railway of Korea

전차선로시스템의 순환전류에 대한 안정성 향상에 관한 고찰

  • Published : 2006.05.26

Abstract

In these days, Korea Railway apply simple catenary system to general lines and high speed lines of Korea Electric Railway. Circulation Current in catenary system frequently bring undesirable consequences. Namely, the Connector wire has many problems according to a flow of excessive circulation (or traction current) and a sudden rise of temperature on catenary when electric car or locomotive is running in high speed. The occurrence of events by the load increasement do considerable damages to peoples, organizations and systems. In this paper, we proposed the improved changes on the catenary system of a improvement and change of a messenger wire protector, improvement of connector wire,s institution angle and of a replacement the connector wire with a dropper. A case of Circulation Current continually has broken out in Yongdungpo Electric Office's own bailiwick. By or through the medium of these obstacles, we have further use of many studies and considering countermeasures. Therefore, we have to deal with the question in design and execution of catenary system for High Speed Railway because we will spend a lot of time and more money for maintenance than for construction of that.

Keywords