AJM을 이용한 HDM에 의한 잔류응력 계측에 관한 연구 2

  • 발행 : 1990.12.01

초록

Lots of research works have been done to improve the accuracy of the hole drilling method to measure residual stress by many investigators. In this study, first, size effect of specimen was analyzed based on the solution of hole in a strip under tension. If the ratio of hole diameter tothe strip width is less than 0.2, the stress distribution around hold may be given from the solution of hole in an infinite plate. Second, the residual stress above $0.6{\sigma}_y$(yield stress) may be measured less than the actual stress by 10-15 percent. Third, eccentricity of hole relative to the rosette center effects on the accuracy of residual stress measurements by 10 percent. The error due to eccentricity of hole can be corrected by the iteration method or the direct method.

키워드