Uncertainty in the Measurement of Radiative Energy Attenuation through Packed Spheres

구립자층내의 복사에너지 감쇠량계측의 불확정성에 관한 연구

  • Published : 1991.10.01

Abstract

Uncertainty is studied in the measurements of average packing density, thickness of packed spheres and transmittance in the experiments to study the effect of the bed height and the existence of the bed side walls on the transmittance of radiative energy through packed spheres. The packing density of the bed is obtained by counting the number of the spheres packed in three pipes with different heights. The bed height of the packed spheres is estimated from the number of spheres contained in the bed by using the relation between the bed height and the sphere number. The transmittance is obtained by dividing the intensity of the transmitted laser beam by the incoming-beam intensity. From the analysis, the uncertainity in the measurements of transmittance is shown to be less than 10.2%(95% coverage).