Studies on the Effect of the Heavy Metals and CN on the $BOD_{5}$ Measurement

중금속 및 CN이 $BOD_{5}$ 측정에 미치는 영향

  • 어수미 (서울시 보건환경연구원) ;
  • 박성배 (서울시 보건환경연구원)
  • Published : 1991.04.01

Abstract

This study was performed to investigate the effect of heavy metals and CN on BOD$_{5}$ measurement. The results were as follows: 1. The BOD$_{5}$ value decreased 20% in Cd(CdCl$_{2}$) 3.0mg/l, Ni(NiCl$_{2}$) 7.0mg/l, Cu(CuCl$_{2}$) 0.5mg/l, Pb($Pb(NO_{3})_{2}$) 9.0mg/l, Cr($K_{2}Cr_{2}O_{7}$) 1.0mg/l respectively. 2. The BOD$_{5}$ value decreased 10% in Zn($Zn(NO_{3})_{2}$) 5 mg/l, Fe(FeCl$_{3}$) 20mg, /l, and 25% in CN(KCN) 5mg/l, and 40% in Hg(HgCl$_{2}$) 0.2rng/l. 3. In Comparion with BOD Rapid Analyzer, the above mentioned heavy metals concentrations have no effect on BOD$_{5}$ value of that analyzer except CN.