Development of a novel in vitro SPF evaluation method

새로운 in vitro SPF측정법 개발

  • Published : 1995.06.01

Abstract

We have recently developed a novel in vitro SPF evaluation method with a high correlation coefficient (r=0.93) to in vivo SPF values(test sunscreen formulas : cress m, foundation). In this method, the in vitro SPF value was determined by the ratio of the time taken to achieve the minimal erythema dose with and without the sunscreens applied. We also reviewed the dilution and thin-layer methods for in vitro SPF evaluation, and investigated the relationship between irradiance(3$\times$10-3 2.5x 10-5W/cm2) and the degree of erythema. The degree of erythema was similar if t he radiation exposure(40mJ/cm2) was kept constant. It was obtained more than 0.90 correlation coefficient when it was compared the results by our new method with those from SPF-290 analyzer (Optometries, U.S.A.).

본 연구에서는 SPF 측정법에 있어서 널리 사용되어온 희석법과 박막법의 문제점에 대해 검토하였으며, 이들의 문제점을 극복하기 위하여 인체를 대상으로한 in vivo평가법과 측정 및 평가 등의 실험조건에 있어서 유사성을 갖는 in vitro평가법을 개발하였다. 이 새로운 in vitro 평가결과는 in vivo 평가결과와 0.93의 높은 상관계수를 나타내었다. 한편 이 in vitro 측정법의 유용성을 더욱 확인하기 위하여 TransporeR tape에 시료를 도포한 후 SPF-290 분석기를 이용한 측정결과와 비교한 결과 SPF20 이하의 시료일 경우 0.95 이상의 높은 상관계수를 얻을 수 있었다. 또한 광량을 일정하게 유지 시키고 광세기를 변화 시켜 홍반의 정도를 조사한 결과, 광세기와 홍반의 정도에는 관련이 없음을 알 수 있었다.

Keywords