Field Evaluation of Korean Passive Sampler for Organic Vapor

유기용제 측정을 위한 국산 수동식 시료채취기의 현장평가

  • Paik, Nam Won (Industrial Health Program, School of Public Health, Seoul National University) ;
  • Yoon, Chung Sik (Industrial Health Program, School of Public Health, Seoul National University)
  • 백남원 (서울대학교 보건대학원 산업보건학교실) ;
  • 윤충식 (서울대학교 보건대학원 산업보건학교실)
  • Published : 1998.05.29

Abstract

The Korean-made passive samplers were evaluated at the working environment for field testing. Tested materials were n-hexane, toluene and trichloroethylene. The performance of passive samplers depended on types and concentrations of organic vapors. Sampling rates were not steady until certain concentrations. The optimum concentration for determination of airborne toluene by passive samplers was equal to or over 10 ppm which is 1/10 of the Korean occupational exposure limit. Optimum concentration of n-hexane was equal to and over 1 ppm which is 1/50 of Korean occupational exposure limit. But for trichloroehtylene, coefficient of variation was 53.5 %. Passive samplers may be used for determination of n-hexane. For other materials, further study on the performance of Korean-made passive samplers is required.

Keywords

Acknowledgement

Supported by : 한국과학재단