DOI QR코드

DOI QR Code

Shaking table study of a 2/5 scale steel frame with new viscoelastic dampers

  • Chang, K.C. (Department of Civil Engineering, National Taiwan University) ;
  • Tsai, M.H. (Department of Civil Engineering, National Taiwan University) ;
  • Lai, M.L. (3M Company)
  • Published : 2001.03.25

Abstract

Viscoelastic (VE) dampers have shown to be capable of providing structures with considerable additional damping to reduce the dynamic response of structures. However, the VE material appears to be sensitive to the variations in ambient temperature and vibration frequency. To minimize these effects, a new VE material has been developed. This new material shows less sensitivity to variations in vibration frequency and temperature. However, it is highly dependent on the shear strain. Experimental studies on the seismic behavior of a 2/5 scale five-story steel frame with these new VE dampers have been carried out. Test results show that the structural response can be effectively reduced due to the added stiffness and damping provided by the new type of VE dampers under both mild and strong earthquake ground motions. In addition, analytical studies have been carried out to describe the strain-dependent behavior of the VE damper. The dynamic properties and hysteresis behavior of the dampers can be simulated by a simple bilinear model based on the equivalent dissipated energy principle proposed in this study.

Keywords

Acknowledgement

Supported by : National Science Council of Taiwan

References

  1. AIJ (1995), Preliminary Reconnaissance Report of the 1995 Hyogoken-Nanbu Earthquake, Architectural Institute of Japan, April.
  2. ATC17-1 (1993), Proceedings of Seminar on Seismic Isolation, Passive Energy Dissipation, and Active Control, Applied Technology Council, California, March.
  3. Chang, K.C., Oh, S.T., Soong, T.T. and Lai, M.L. (1992), "Effect of ambient temperature on viscoelastically damped structures," J. of Struct. Eng., ASCE, 118(7), 1955-1973. https://doi.org/10.1061/(ASCE)0733-9445(1992)118:7(1955)
  4. Chang, K.C., Soong, T.T., Oh, S.T. and Lai, M.L. (1995), "Seismic behavior of steel frame with added viscoelastic dampers," J. of Struct. Eng., ASCE, 121(10), 1418-1426. https://doi.org/10.1061/(ASCE)0733-9445(1995)121:10(1418)
  5. Chang, K.C., Chen S.J. and Lai, M.L. (1996), "Inelastic behavior of steel frames with added viscoelastic dampers," J. of Struct. Eng., ASCE, 122(10), 1178-1186. https://doi.org/10.1061/(ASCE)0733-9445(1996)122:10(1178)
  6. Chang, K.C., Tsai, M.H., Chang, Y.H. and Lai, M.L. (1998), "Temperature rise effect of viscoelastically damped structures under strong earthquake ground motions," The Chinese Journal of Mechanics, 14(3), 125-135.
  7. Darragh, R., Cao, T., Cramer, C. Huang, M. and Shakal, A. (1994), "Processed CSMIP strong-motion records from the Northridge, California earthquake of January 17, 1994: Release No.1", Report No. OSMS 94-06B, California Strong Motion Instrumental Program, California Department of Conservation Division of Mines and Geology, Office of Strong Motion Studies, 801 K Street, Ms 13-35, Sacramento, California, February 1994.
  8. EESI (1993), "Passive energy dissipation issue", Earthquake Spectra, Earthquake Engineering Research Institute, Oaklang, California, August, 9(3).
  9. Kasai, K., Munshi, J.A., Lai, M.L. and Maison, B.F. (1993), "Viscoelastic damper hysteretic model: Theory, experiment, and application", Proceedings of Seminar on Seismic Isolation, Energy Dissipation, And Active Control, ATC-17-1, 2, 521-532.
  10. Mahmoodi, P. (1969), "Structure dampers," J. of Struct. Div., ASCE, 95(10), 1661-1672.
  11. Shen, K.L., Soong, T.T., Chang, K.C. and Lai, M.L.(1995). "Seismic behavior of A 1/3 scale RC frame with added viscoelastic dampers," Engineering Structures, 17(5), 372-380. https://doi.org/10.1016/0141-0296(95)00020-8
  12. Tsai, K.C. and Li, J.W. (1994), "DRAIN2D+, A General purpose computer program for static and dynamic analyses of inelastic 2D structures, supplemented with a graphic processor VIEW2D, User's Guide", Report No. CEER/R83-03, Center for Earthquake Engineering Research, National Taiwan University, Taipei, Taiwan.

Cited by

  1. Performance Study of an Eight-story Steel Building Equipped with Oil Dampers Damaged During the 2011 Great East Japan Earthquake Part 1: Structural Identification and Damage Reasoning vol.14, pp.1, 2015, https://doi.org/10.3130/jaabe.14.181
  2. Experimentally validated FEA models of HF2V damage free steel connections for use in full structural analyses vol.37, pp.4, 2001, https://doi.org/10.12989/sem.2011.37.4.385