자동차 에어컨용 냉매인 HFC-134a와 OS-12a의 성능 특성에 관한 연구

A Study on Characteristics of HFC-l34a and OS-l2a Refrigerant in Automobile Air-Conditioning System

  • 이종인 (조선이공대학 자동차과) ;
  • 하옥남 (조선대학교 기계공학부)
  • 발행 : 2002.05.01

초록

HFC-134a is currently used as the refrigerant in automobile air-conditioner, replacing the ozone depleting refrigerant CFC-12. Although HFC-l34a has no ozone depletion potential, it has a relatively high global warming potential, approximately 1300 tins that of CO$_2$ over a 100 year time horizon. Therefore, HFC- l34a does not seem to be a perfect alternative refrigerant due to high GWP. For this reason, non-azeotrope refrigerant mixture have been proposed as a long-term and drop-in alternative to HFC-l34a in the automobile air-conditioning system which has variable operating conditions with changes in RPM and pressure ratio. In this study,OS-l2a of which thermodynamic properties are similar to those of HFC-l34a is selected among the mixed refrigerant. HFC-l34a and OS-l2a are examined experimently by the performance test in the same automobile air-conditioning system.

키워드

참고문헌

  1. H. N. An, 'Study on Use of New Refrigerant in the Motor vehicle,' The Society of Air-condition-ing and Refrigerating Engineers of Korea, Vol. 25, No.6, pp.515-523, 1996
  2. M. Mclinden, S. Klein, E. Lemmin, A. Peskin NIST Thermodynamic and Transport Properties of Refigerants and Refrigerant Mixtures(REFPROP) Version 6.0, National Institute of Standards and Technology, Boulder, Co., U.S.A., 1998
  3. D. S. Jung, 'Development Trend of New Alternative Refrigerant,' The Society of Air-conditioning and Refrigerating Engineers of Korea, Vol.25, No.6, pp.479-488, 1996
  4. H. C. Lee, B. J. Park, D. S. Jung, S. J. Oh, E. K. Jung, 'Performance of Alternative Refrigerant Mixtures Containing CF3I for CFC12 in Automobile Air Conditioners,' The Society of Air-conditioning and Refrigerating Engineers of Korea Pro-ceedings of the SAREK '99 Summer Annual Conference(I), pp.219-224, 1999
  5. J. S. Han, J. G. Youn, S. P. Won, 'A Study on Per-formance Characteristic of a New Alternative Re-frigerant Replacing HFC- 134a,' The Society of Air-conditioning and Refigerating Engineers of Korea Proceedings of the SAREK '99 Summer Annual Conference(I), pp.219-224, 1999
  6. S. Soloman, D. Wuebbles, ODPs, GWPs, and Future Chlorine/Bromine Loading, Scientific Assessment of Ozone Depletion, pp. 131-136, 1994
  7. UNEP, Report of the Secretariat on the Reporting of Data by the Parties in Accordance With Article of the Montreal Protocal, UNEP/Ozl. Pro. 3/5, 1991
  8. C. W. Bullard, R. Radermacher, New Technologies for Air Conditioning and Refrigeration, Annu. Rev. Energy Environ, pp. l13-152. 1994
  9. S. L. Smith, 'Void Fraction in Two-phase Flow: A Correlation based on an Equal Velocity Heated Model,' Proc. Inst. Mech. Engng, pp.647-657, 1970