DOI QR코드

DOI QR Code

Development of diameter 450 mm Cassegrain tlne collimator

직경 450 mm Cassegrain 형태 시준장치의 제작

  • 양호순 (한국표준과학연구원 광기술표준부) ;
  • 이재협 (한국표준과학연구원 광기술표준) ;
  • 이윤우 (한국표준과학연구원 광기술표준) ;
  • 이인원 (한국표준과학연구원 광기술표준) ;
  • 김종운 ((주)쎄트렉아이 광학) ;
  • 김도형 ((주)쎄트렉아이 광학팀)
  • Published : 2004.06.01

Abstract

The collimator is necessary for the assembly and evaluation of high resolution satellite telescope. Traditionally, the off-axis paraboloid has been used as a collimator. However, it has some disadvantages in that it can suffer from air turbulence when the focal length of a collimator is long, which may result in some error in the measurement. In contrast, since the Cassegrain type collimator folds the beam, it occupies smaller space compared to the off-axis paraboloid for the same focal length. This can reduce the air turbulence, which can improve the measurement accuracy. In this paper, we explain the process of design and manufacturing of a diameter 450 mm Cassegrain type collimator, to evaluate the diameter 300 mm satellite telescope. After assembly of primary and secondary mirrors, the final wavefront error of the collimator was 0.07λ(λ=633 nm), which is the diffraction limit.

고해상도 인공위성용 망원경의 조립 및 평가를 위해서는 평행빔 만들어주는 시준장치가 꼭 필요하다. 전통적으로 큰 직경의 시준장치로는 비축포물면 거울을 많이 사용하여 왔다. 하지만, 평가대상망원경의 초점거리가 긴 경우 비축포물면은 보다 긴 초점거리를 가져야 하고 공기의 유동효과를 효과적으로 제어하지 못할 경우, 정확한 평가가 이루어지기 어려운 단점이 있다. 이에 비해 Cassegrain 형태 시준장치는 빔을 꺾어 사용하므로, 초점거리에 비해 적은 공간을 차지하고 공기의 유동효과도 상당히 줄일 수 있는 장점이 있다. 따라서, 본 논문에서는 직경 300 mm 인공위성 망원경을 측정하기 위해 직경 450 mm 의 Cassegrain 형태 시준장치를 설계하고 제작한 과정을 설명한다. 주경 및 부경을 제작한 후 시준장치를 구성한 결과 최종 파면수차는 0.07λ(λ=633 nm)로 diffraction limited 성능을 보였다.

Keywords

References

  1. Proc. SPIE v.3750 "Wide field-of-view Schmidt-sphere imaging collimator," in Earth Observing Systems Ⅳ B.C.Willard;W.L.Barnes(Ed.) https://doi.org/10.1117/12.363522
  2. Proc. SPIE v.3750 "Spatial calibration of the EO-1 Advanced Land Imager." in Earth Observing Systems Ⅳ D.R.Hearn(et al.);W.L.Barnes(Ed.) https://doi.org/10.1117/12.363503
  3. D. B. Leviton et al., "Wide-field imaging interferometry testbed 3: metrology subsystem," in Inteferometry in Space, M. ShaO, Ed., Proc. SPIE vol. 4852, pp. 827-838, 2003. https://doi.org/10.1117/12.460948
  4. Proc. SPIE v.4852 "Wide-field imaging interferometry testbed 3: metrology subsystem." in Inteferometry in Space D.B.Leviton(et al.);M.ShaO(Ed.) https://doi.org/10.1117/12.460948
  5. J.W.Figoski, "Alignment and test results of the QuickBird Telescope using the Ball Optical System Test Facility," in Advanced Telescope Design, Fabrication, and Control, W. Roybal, Ed., Proc. SPIE vol. 3785, pp. 99-108, 1999. https://doi.org/10.1117/12.367607
  6. Proc. SPIE v.3782 'Interferometric alignment and figure testing of large(0.5 m) off-axis parabolic mirrors in a challenging cleanroom environment." in Optical Manufacturing and Testing Ⅲ R.H.Barkhouser;R.G.Ohl;H.p.Stahl(Ed.) https://doi.org/10.1117/12.369210
  7. Proc. SPIE v.3785 "Alignment and test results of the QuikBird Telescope using the Ball Optical System Test Facility," in Advanced Telescope Design, Fabrication, and Control J.W.Figoski;W.Roybal(Ed.) https://doi.org/10.1117/12.367607
  8. Testing and Evalustion of Infrared Imaging Systems G.C.Holst
  9. Proc. SPIE v.2199 "Defining mirror qualiy: a global approach," in Advanced Technology Optical Telescopes Ⅴ Rajiv, Bhatia;Adriana, Ciani;L.M.Stepp(Ed.) https://doi.org/10.1117/12.176166
  10. Optical Shop Testing, Appendix 2 D.Malacara
  11. 한국광학회지 v.12 no.5 쌍곡면 측정 null 렌즈 설계 김연수;김병윤;이윤우
  12. Modern Optical Engineering W.J.Smith

Cited by

  1. Optical design and tolerance analysis of a new off-axis infrared collimator vol.15, pp.9, 2014, https://doi.org/10.1007/s12541-014-0542-3