DOI QR코드

DOI QR Code

표면플라즈몬공명과 효소면역분석법을 이용한 살충제 카보후란 잔류물 검출

Sensing of the Insecticide Carbofuran Residues by Surface Plasmon Resonance and Immunoassay

  • Yang G. M. (Researcher National Institute of Agricultural Engineering, Agricultural Safety Evaluation Lab.) ;
  • Cho N. H. (Researcher National Institute of Agricultural Engineering.)
  • 발행 : 2005.12.01

초록

The pesticide is raising public interest in the world, because it causes damage to an environmental pollution and the human health remaining agricultural products and an ecosystem, in spite of the advantages. Particularly, each country restricts the residual pesticide and induces observance about the safety and usage standard so that they can control the amount of pesticide used and defend the safety of agricultural products. The habitual practice for the analysis of the residual pesticide depends on GC (gas chromatography), HPLC (high performance liquid chromatography) and GC/MS (gas chromatography/mass spectroscopy), which triturate the fixed quantity of samples, abstract and purify as a suitable organic solvent. These methods have the highly efficient in aspects of sensitivity and accuracy. On the other hand, they need the high cost, time consuming, much effort, expensive equipment and the skillful management. Carbofuran is highly toxic by inhalation and ingestion and moderately toxic by dermal absorption. As with other carbamate compounds, it is metabolized in the liver and eventually excreted in the urine. The half-life of carbofuran on crops is about 4 days when applied to roots, and longer than 4 days if applied to the leaves. This research was conducted to develop immunoassay for detecting carbofuran residue quickly on the basis of surface plasmon resonance and to evaluate the measurement sensitivity. Gold chip used was CM5 spreaded dextran on the surface. An applied antibody to Immunoassay was GST (glutathione-s-transferase). The association and the dissociation time were 176 second and 215 second between GST and carbofuran. The total analysis time using surface plasmon resonance was 13 minutes including regeneration time, on the other hand HPLC and GC/MS was 2 hours usually. The minimum detection limit of a permissible amount for carbofuran in the country is 0.1 ppm. The immunoassay method using surface plasmon resonance was 0.002 ppm.

키워드

참고문헌

  1. Abad J. M., F. Pariente, L. Hernandez, H. D. Abruna, and E. Lorenzo. 1998. Determination of Organophosphorus and Carbamate Pesticides Using a Piezoelectric Biosensor, Anal. Chem. 70:2848-2855 https://doi.org/10.1021/ac971374m
  2. Bu, K. S. and S. J. Kim. 2002. Development of a diagnosis kit for detecting residual pesticides using insect enzyme and field test, ARPC final report
  3. Choi, J. W. and W. H. Lee. 2002. The development of fiver-optic biosensor for simultaneous detection of the pesticide residues in agricultural products, ARPC final report
  4. K-MAC. 2000. Development of surface plasmon resonace sensor system, K-MAC report
  5. Lea Pogacnik , Mladen Franko. 2003. Detection of organophosphate and carbamate pesticides in vegetable samples by a photothermal biosensor, Biosensors and Bioelectronics 18:1-9 https://doi.org/10.1016/S0956-5663(02)00056-8
  6. Shim, J. H. and Y. T. Ji. 2003. Microorganism selection and kit development for detection of the germicide EBDC pesticide residues in agricultural products, ARPC final report
  7. Song, S. J. and H. K. Cho. 2003. Enzyme immunoassay for on-line sensing of the insecticide imidaclopird residues, KSAM 28(6):505-510
  8. Weller, M. G., J. S. Andreas, M. Winklmail and R. Niessner. 1999. Highly parallel affinity sensor for the detection of environmental contaminants in water. Snal. Chim. Acta, 393: 29-41 https://doi.org/10.1016/S0003-2670(98)00855-1

피인용 문헌

  1. An opto-fluidic ring resonator biosensor for the detection of organophosphorus pesticides vol.133, pp.1, 2008, https://doi.org/10.1016/j.snb.2008.02.004