The permeability of concrete affects largely on the durability of concrete, therefore it is required that the correct assessment and improvement of permeability. Therefore it is rational method that the permeability of concrete structures is estimated in the common use states under loading than in the early sound conditions. In this study, to improve the permeable efficiency of concrete, some kinds of fiber and resin are mixed in making of concrete specimens. And also, for the reasonable assessment of permeability, after 50% and 70% pre-loadings of its compressive strength were acted on the specimens, the tests were executed. From the results of this study, in the case of 50% pre-loading coefficients of permeability were increased about 1.4times against the nonpre-loading specimens and in the case of 70% pre-loading they were increased about 17.8times. And it turned out that hybrid steel fiber reinforcement is most effective for the improvement of permeable efficiency of concrete.

콘크리트의 투수성은 콘크리트의 내구성에 크게 영향을 미치므로, 투수성의 합리적인 측정과 그 개선이 요구된다. 따라서 콘크리트의 투수성은 콘크리트 구조물이 건전한 상태를 유지하고 있는 초기 상태에서 평가하는 것 보다 실제 하중을 받고 있는 공용중인 상태에서 평가하는 것이 보다 합리적이라 할 수 있다. 본 연구에서는 콘크리트의 투수성능을 개선하기 위하여 섬유의 종류 및 혼입율, 수지 종류를 달리하여 콘크리트 시험체를 제작하였으며, 투수성의 합리적인 평가를 위해서 하중을 받아 균열발생 등 성능이 저하된 콘크리트 구조물의 실제 상태를 모사하기 위하여 시험체에 선행하중을 시험체 압축강도의 50%, 70% 작용시킨 후에 투수시험을 수행하여 그 결과를 비교분석 하였다. 시험결과 투수계수는 선행하중을 가하지 않은 경우보다 선행하중 50%일 때 대략 1.4배, 70%일 때 17.8배 증가되었고, 하이브리드 강섬유보강이 콘크리트의 투수성능 개선에 가장 효과적임을 알 수 있었다.