An Experimental Study of Liquid.Gas Heat Exchange Pipe Inserted Capillary Tube for Room Air-Conditioner

모세관 삽입 룸 에어컨용 액.가스 열교환 배관에 관한 실험적 연구

  • 김재돌 (동명대학교 환경설비공학과)
  • Published : 2006.09.30

Abstract

This study shows the experimental characteristics of the double pipe inserted liquid pipe with small diameter in the gas pipe with large diameter for circulating of a liquid of high temperature, pressure and a gas of low temperature, pressure at the same time. So the functions of pipe and pipe's expansion and heat transfer are presented simultaneously. In the result, the temperature of gas refrigerant at the inlet of compressor increased about $5^{\circ}C$ by the heat transfer with liquid refrigerant in case of the double pipe. And liquid gas refrigerant which the temperature at the inlet of evaporator decreased about $3^{\circ}C$ comparing with the existing type flows into an evaporator COP of the double pipe increased about $7{\sim}10%$ comparing with that of the conventional pipe. And the noise of the double pipe at capillary tube is less than that of the conventional type about 3dB. Consequently. it is convinced the superiority of the double pipe in the heat loss and soundproofing aspect.

Keywords

References

  1. Frank M. White, 'Fluid Mechanics', McGraw Hill 3th Edition, pp. 361-410, 1995
  2. ASHRAE, 'Refrigeration Systems and Applications', pp. 3.1-3.25, 1990
  3. 방덕제, 김재돌, 윤정인, 'HCFC22 냉동 공조 장치의 배관결정', 공기조화 냉동공학회 학술발표회 논문집, pp. 282-286, 1996
  4. 池元眞佐美, 山本泰司, 黑河通匡, 名迫賢二, 片岡久典, 'HFC冷媒.冷凍サイクルシミュレーション', 第30回空氣調和․冷凍聯合講演論文集, pp. 173-176, 996
  5. 설원실, 김재돌, 윤정인, '냉매 배관 길이가 냉동장치의 성능에 미치는 영향, 한국박용기관학회 추계학술대회 논문집, pp. 68-73, 1997
  6. 최인수, 김재돌, 윤정인, '실외기 설치위치가 냉동시스템의 성능에 미치는 영향', 공기조화 냉동공학회 동계학술발표회 논문집, pp. 313-318, 1997
  7. 김태현, 김진국, 이건우, 이재효, '저소음 패키지 에어컨 실내기 개발에 관한 연구', 공기조화냉동공학회 2000 하계학술발표회 논문집, pp. 314-320, 2000