DOI QR코드

DOI QR Code

Defect Detection of Ceramic Heating Plate Using Ultrasound Pulse Thermography

초음파 펄스 서모그라피를 이용한 세라믹 전열 판의 결함 검출

  • Cho, Jai-Wan (Nuclear Robotics Lab., Korea Atomic Energy Research Institute) ;
  • Seo, Yong-Chil (Nuclear Robotics Lab., Korea Atomic Energy Research Institute) ;
  • Jung, Seung-Ho (Nuclear Robotics Lab., Korea Atomic Energy Research Institute) ;
  • Kim, Seung-Ho (Nuclear Robotics Lab., Korea Atomic Energy Research Institute) ;
  • Jung, Hyun-Kyu (Nuclear Robotics Lab., Korea Atomic Energy Research Institute)
  • 조재완 (한국원자력 연구소 원자력 로봇 Lab.) ;
  • 서용칠 (한국원자력 연구소 원자력 로봇 Lab.) ;
  • 정승호 (한국원자력 연구소 원자력 로봇 Lab.) ;
  • 김승호 (한국원자력 연구소 원자력 로봇 Lab.) ;
  • 정현규 (한국원자력 연구소 원자력 로봇 Lab.)
  • Published : 2006.04.01

Abstract

The applicability of UPT (Ultrasound Pulse Thermography) for real-time defect detection of the ceramic heating plate is described. The ceramic heating plate with superior insulation and high radiation is used to control the water temperature in underwater environment. The underwater temperature control system can be damaged owing to the short circuit, which resulted from the defect of the ceramic heating plate. A high power ultrasonic energy with pulse duration of 280 ms was injected into the ceramic heating plate in the vertical direction. The ultrasound excited vibration energy sent into the component propagate inside the sample until they were converted to the heat in the vicinity of the defect. Therefore, an injection of the ultrasound pulse wave which results in heat generation, turns the defect into a local thermal wave transmitter. Its local emission is monitored and recorded via the thermal infrared camera at the surface which is processed by image recording system. Measurements were Performed on 4 kinds of samples, composed of 3 intact plates and the defect plate. The observed thermal image revealed two area of crack in the defective ceramic heating plate.

Keywords

References

  1. R. B. Mignogna, R. E. Green Jr., J. C. Duke Jr., E. G. Henneke II, and K. L. Reifsnider, 'Thermographic Investigation of High-Power Ultrasonic Heating in Materials,' Ultrasonics, 19 159-63 (1981) https://doi.org/10.1016/0041-624X(81)90095-0
  2. M. Zong, J. Zhang, and Y. Zhao, 'Pulse-Heating Infrared Thermography Non-Destructive Testing Technique,' Proceedings of SPIE, 2899 654-59 (1996)
  3. G. Busse, D. Wu, and W. Karpen, 'Thermal Wave Imaging with Phase Sensitive Modulated Thermography,' J. Appl. Phys., 71 [8] 3962-65 (1992) https://doi.org/10.1063/1.351366
  4. A. Dillenz, G. Busse, and D. Wu, 'Ultrasound Lockin Thermography : Feasibilities and Limitations,' Proceedings of SPIE, 3827 10-5 (1999)
  5. T. Zweschper, G. Riegart, A. Dillenz, and G. Busse, 'Ultrasound Burst Phase Thermography (UBP) for Applications in the Automotive Industry,' AIP Conference Proceedings, 657 531-36 (2003)
  6. M. Rothenfusser and C. Homma, 'Acoustic Thermography : Vibrational Modes of Cracks and the Mechanism of Heat Generation,' Review of Quantitative Nondestructive Evaluation, 24 624-31 (2005)
  7. G. Busse, A. Dillenz, and T. Zweschper, 'Defect-Selective Imaging of Aerospace Structures with Elasticwave Activated Thermography,' Proceedings of SPIE, 4360 580-86 (2001)
  8. http://www.sunceratech.com/