Comparison of 64 Channel 3 Dimensional Volume CT with Conventional 3D CT in the Diagnosis and Treatment of Facial Bone Fractures

얼굴뼈 골절의 진단과 치료에 64채널 3D VCT와 Conventional 3D CT의 비교

  • Jung, Jong Myung (Departments of Plastic and Reconstructive Surgery, National Medical Center) ;
  • Kim, Jong Whan (Departments of Plastic and Reconstructive Surgery, National Medical Center) ;
  • Hong, In Pyo (Departments of Plastic and Reconstructive Surgery, National Medical Center) ;
  • Choi, Chi Hoon (Departments of Radiology, National Medical Center)
  • Received : 2007.05.07
  • Published : 2007.09.10

Abstract

Purpose: Facial trauma is increasing along with increasing popularity in sports, and increasing exposure to crimes or traffic accidents. Compared to the 3D CT of 1990s, the latest CT has made significant improvement thus resulting in higher accuracy of diagnosis. The objective of this study is to compare 64 channel 3 dimensional volume CT(3D VCT) with conventional 3D CT in the diagnosis and treatment of facial bone fractures. Methods: 45 patients with facial trauma were examined by 3D VCT from Jan. 2006 to Feb. 2007. 64 channel 3D VCT which consists of 64 detectors produce axial images of 0.625 mm slice and it scans 175 mm per second. These images are transformed into 3 dimensional image using software Rapidia 2.8. The axial image is reconstructed into 3 dimensional image by volume rendering method. The image is also reconstructed into coronal or sagittal image by multiplanar reformatting method. Results: Contrasting to the previous 3D CT which formulates 3D images by taking axial images of 1-2 mm, 64 channel 3D VCT takes 0.625 mm thin axial images to obtain full images without definite step ladder appearance. 64 channel 3D VCT is effective in diagnosis of thin linear bone fracture, depth and degree of fracture deviation. Conclusion: In its expense and speed, 3D VCT is superior to conventional 3D CT. Owing to its ability to reconstruct full images regardless of the direction using 2 times higher resolution power and 4 times higher speed of the previous 3D CT, 3D VCT allows for accurate evaluation of the exact site and deviation of fine fractures.

Keywords

References

  1. Artzy E, Frieder C, Herman GT: The theory, design, implementation and evaluation of a three-dimensional surface detection algorithm. Computer Graphics Image Process 15: 1, 1981 https://doi.org/10.1016/0146-664X(81)90103-9
  2. Marsh JL, Vannier MW: The "third" dimension in craniofacial surgery. Plast Reconstr Surg 71: 759, 1983 https://doi.org/10.1097/00006534-198306000-00002
  3. Marsh JL, Vannier MW: Surface imaging from computerized tomographic scans. Surgery 94: 159, 1983
  4. Vannier MW, Gado MH, Marsh JL: Three-dimensional display of intracranial soft-tissue structures. AJNR Am J Neuroradiol 4: 520, 1983
  5. Totty WG, Vannier MW: Complex musculoskeletal anatomy; analysis using three dimensional surface reconstruction. Radiology 150: 173, 1984 https://doi.org/10.1148/radiology.150.1.6689757
  6. Shimizu T, Youshikawa S, Uesugi Y, Tabuchi K, Nakata Y, Matsui R, Sueyoshi K, Narabayashi I: Three dimensional computed tomographic angiography of pulmonary vessels. Radiat Med 17: 151, 1999
  7. Kim MS, Han KT, Lim P: Three dimensional CT images in diagnosis of craniofacial deformities. J Korean Soc Plast Reconstr Surg 17: 596, 1990
  8. Han DG, Park DH: Comparison of three-dimensional CT images with conventional CT images in the diagnosis of the facial bone fractures. J Korean Soc Plast Reconstr Surg 24: 78, 1997
  9. Park C, Lee YH, Suh CH: Computerized tomogram(C-T) in plastic and reconstructive surgery. J Korean Soc Plast Reconstr Surg 7: 329, 1980