Estimation of Optimum PP Fiber Content for the Spalling Control of High Strength Reinforced Concrete Columns

고강도 철근콘크리트 기둥의 폭열제어를 위한 최적의 PP섬유함유량 산정

  • Received : 2006.11.13
  • Published : 2007.03.30

Abstract

High Strength Concrete (HSC) has weakness that in a fire, it is spalled and brittles. The phenomenon of spalling is made by water vapor's (resulting from evaporation in the material at over $100{^{\circ}C}$)' being confined in watertight concrete. As the concrete strength increases, the degree of damage caused by the spalling becomes more serious because of the permeability. It is reported that the polypropylene(PP) fiber has an important role in protecting concrete from spalling and the optimum dosage of PP fiber is 0.2%. This study was conducted on the nonreinforced concrete specimens. The high-temperature behavior of high-strength reinforced concrete columns with various concrete strength and various dosage of PP fibers was investigated in this study. The results show that the ratio of unstressed residual strength of columns increases as the concrete strength increases and the ratio of unstressed residual strength of columns increases as the dosage of PP fiber increases from 0% to 0.2%, however, the effect of fiber dosage on residual strength of column barely changes above 0.2%.

고강도 콘크리트(HSC)는 화재 시 폭렬현상과 함께 부재가 취성적인 거동을 하게 되는 단점을 지니고 있다. 폭렬현상은 화재 시 $100{^{\circ}C}$이상에서 부재내부의 수분 증발로 인하여 발생한 수증기가 수밀한 콘크리트에 갇혀 발생한다. 따라서 콘크리트 강도가 증가 할수록 수밀성이 높아져 폭렬의 정도가 심해진다. 콘크리트의 폭렬을 제어할 수 있는 방안으로는 폴리프로필렌 섬유(PP섬유)를 혼입하는 방법이 가장 효율적인 것으로 보고 되었다. 본 연구에서는 콘크리트 강도와 PP섬유 함유량을 변수로 하는 기둥 실험체에 대한 내화실험과 잔존강도실험을 수행하여 폭렬현상을 관찰하고 잔존강도를 측정하였다. 그 결과 콘크리트 강도가 60MPa에서 85MPa로 증가할 때 기둥 실험체의 잔존 축 강도는 10%증가하였다. 또한, PP섬유 함유량이 0%에서 0.2%까지 증가 할수록 잔존 축강도비는 68%에서 85%까지 증가하였으나, PP섬유 함유량이 0.2%이상에서는 잔존강도의 증가가 거의 나타나지 않았다.

Keywords

References

  1. 김무한, 윤현도, 유재철, 강선종, 김규용, "초고강도 콘크리트의 내화성능에 관한 일본건설사의 연구동향 및 성능인증 현황", 콘크리트학회지 제17권 5호, 2005.
  2. 한천구, 양성환, 이병열, 황인성, "골재종규 및 폴리프로필렌 섬유 혼입률 변화에 따른 고성능 콘크리트의 폭렬특성에 관한 연구", 콘크리트학회논문집 제11권 5호 통권53호, 1999, pp. 69-78.
  3. 권영진, 장재봉, 나철성, 김무한, "고성능 콘크리트의 폭렬현상과 대책에 관한 연구동향", 콘크리트학회지 제17권 3호 통권86호, 2005.
  4. L. Sarvaranta, E. Mikkola, "Fiber mortar composites in fire conditions", Fire Mater 18, 1994, pp. 45-50. https://doi.org/10.1002/fam.810180106
  5. L. Sarvaranta, E. Mikkola, "Fiber mortar composites under fire conditions: Effects of ageing and moisture content of specimens", Mater Struct. 27, 1994, pp. 532-538. https://doi.org/10.1007/BF02473214
  6. Pierre Kalifa, "High-Temperature behaviour of HPC with polypropylene fibers from spalling to microstructures", Cement and Concrete Research, Jun., 2001, pp.1487-1499.
  7. L. Sarvaranta, E. Jarvela, E. Mikkola, Fiber mortar composites under thermal ezposure, in: Pluralis(Ed.), Proceedings of 2nd International Symposium on Textile Composites in Building Construction, Lyon, France, 23-25 June 1992, pp. 47-56.
  8. D. Bentz, "Fibers, percolation and spalling of high performance concrete", ACI material Journal, March, 2000, pp.351-359.
  9. Zdenek P. Bazant, Maurice F. Kaplan, "Concrete at High Temperatures : Material Properties and Mathematical Models", Prentice Hall, 1996.
  10. NIST, "International Workshop on Fire Performance of High-Strength Concrete", Md Gaithersburg, Feb., 1997.
  11. NISTIR 5934, "Fire Performance of High-Strength Concrete : A Report of the State-ofthe-Art", NIST, Dec., 1996.
  12. Sullivan, P.J.E., and Sharshar, R., "Performance of concrete at elevated temperatures(as measured by the reduction in compressive strength", Fire Technology, V. 28, No. 3, August, 1992, pp. 240-250. https://doi.org/10.1007/BF01857693