Luminance Performance of a Room with Light Guide and Blind Systems by Mockup Experiments

혼합형 채광조절장치가 실내공간의 휘도분포에 미치는 영향에 관한 Mockup 실험평가

  • Published : 2007.02.28

Abstract

As ecological design elements, daylighting can be applied to provide adequate illumination on visual tasks to create an attractive visual environment and to save electrical energy. Daylighting control systems reject direct sunlight and penetrate it onto the ceiling or to deep into the room. This study aims to evaluate the luminance environment of sloped light guide with automated venetian blind systems according to sun angle changes. For evaluation, a mock-up model was used and the south facing side-window mounted between the clerestory window and the view window. To assess luminance performance, 3 view points of luminance were monitored. As results, the conventional and lightshelves show ideal luminance ratio between workplane and surroundings(3:1) and workplane and darkness area(2:1) due to total ratio of surroundings and darkness area has lower ratio than workplane. Compared to the lightshelves window, conventional window shows unrelieved effect in between the workplane and brightness area(1:5). It means that there has low deviation according to the required standards. Also, compared to the ratio between the brightness area and darkness area(2~6:1) conventional window with high deviation(10~20:1) provide discomfort glare due to the excessively strong contrast, while lightshelves window shows a required luminance ratio that provide a three-dimensional effect to occupants. Therefore, luminance distribution indicate that application of a lightshelves and blinds not only has a significantly positive effect but also offers higher luminance quality in a daylit room

Keywords

Acknowledgement

Supported by : 과학재단

References

  1. 김정태, 신현구, 김곤, "광반사를 이용한 광선반 채광시스템의 기본 형상 설계 및 성능평가에 관한 연구", 대한건축학회논문집, 19권 3호, 2003.3
  2. 문기훈, 김정태, "Lightscape 이용한 광선반채광시스템 채광성능평가", 한국생태환경건축학회논문집, 4권 4호, 2004.12
  3. 송규동, "RADIANCE 프로그램을 이용한 베네치안 블라인드의 차양특성 분석" 한국생태환경건축학회 논문집, 5권 3호, 2006. 9
  4. 화영외, '라이트가이드와 블라인드시스템이 통합 적용된 사무소공간의 주광환경특성분석', 한국생태환경건축학회 학술발표대회논문집, 2006.11, pp179-183
  5. 신현구, 경희대학교 석사학위논문, "광반사를 이용한 광선반 채광시스템의 기본형상 설계 및 성능평가에 관한 연구", 2003
  6. 심인보, 경희대학교 석사학위논문, "광선반 채광시스템의 시각적 성능 평가", 2006
  7. 정근영, 최안섭, "RADIANCE 프로그램에 의한 창문 블라인드의 투과율 분석 연구", 조명.전기설비학회 논문집, 17권 6호 2003.11
  8. Eleanor Lee et al, "Advancement of Electrochromic Windows", Lawrence Berkeley National Laboratory, 2006
  9. Hiroshi Tamura, ""Measurement and subjective experiments on window systems for controlling sunlight", Dept. of Architect, Tokai University
  10. Michael Laar, Lightshelves and Fins-Carrying on Where the Tropical Modernism Lift Off. 7th International IBPSA Conference, 2001, pp.1335-1340
  11. Hayashi, T. Watanabe, T, Katayama, T, "Time- Variable Numerical Model of Heat Transfer around Solar Shading Devices in Window", Thermal Performance of the Exterior Envelopes of Building IV, pp. 405-413, 1989
  12. Koster Helmut, "Dynamic Daylighting Architecture : Basics, Systems, Projects", Springer Verlag, 2004
  13. IEA SHC Task 21, "Daylighting in Buildings", 1998
  14. M. David Egan, "Concepts in Architectural Lighting", 1983
  15. William M. C. LAM, "Sunlighting as Formgiver for Architecture", 1999
  16. www.iea-shc.org