CT Number Measurement of Residual Foreign Bodies in Face

안면부에 잔류된 다양한 이물질을 측정한 CT 계수

  • Wee, Syeo Young (Department of Plastic and Reconstructive Surgery, College of Medicine, Soon Chun Hyang University) ;
  • Choi, Hwan Jun (Department of Plastic and Reconstructive Surgery, College of Medicine, Soon Chun Hyang University) ;
  • Kim, Mi Sun (Department of Plastic and Reconstructive Surgery, College of Medicine, Soon Chun Hyang University) ;
  • Choi, Chang Yong (Department of Plastic and Reconstructive Surgery, College of Medicine, Soon Chun Hyang University)
  • 위서영 (순천향대학교 의과대학 성형외과학교실) ;
  • 최환준 (순천향대학교 의과대학 성형외과학교실) ;
  • 김미선 (순천향대학교 의과대학 성형외과학교실) ;
  • 최창용 (순천향대학교 의과대학 성형외과학교실)
  • Received : 2008.03.04
  • Accepted : 2008.05.02
  • Published : 2008.07.10

Abstract

Purpose: Computed tomography theoretically should improve detection of foreign bodies and provide more information of adjacent soft tissues. And the CT scanner and PACS program proved to be an excellent instrument for detection and localization of most facial foreign bodies above certain minimum levels of detectability. The severity of injury in penetrating trauma to the face, it is often underestimated by physical examination. Diagnosis of a retained foreign object is always critical. Methods: From March, 2005 to February 2008 a study was done with 200 patients who had facial trauma. Axial and coronal CT images were obtained with a General Electric(Milwaukee, Wis) 9800 CT scanner at 130 kV, 90 mA, with a 2-mm section thickness and a $512{\times}512$ matrix. Results: Axial and coronal CT images at various window widths should be used as the first imaging modality to detect facial foreign bodies. The attenuation coefficients for the metallic and nonmetallic foreign bodies ranged from -437 to +3071 HU. As a general rule, metallic foreign bodies produced more Hounsfield artifacts than nonmetallic foreign bodies, thus providing a clue to their composition. All of the metallic foreign bodies were represented by a single peak and had a maximum attenuation coefficient of +3071 HU. Of the nonmetallic foreign bodies, glass had an attenuation coefficient that ranged from +105 to +2039, while plastic had a much lower coefficient that ranged from -62 to -35. wood had the lowest range of attenuation coefficients: -491 to -437. Conclusion: The PACS program allows one to distinguish metallic from nonmetallic foreign bodies and to individually identify the specific composition of many nonmetallic foreign bodies. This program does not, however, allow identification of the specific composition of a metallic foreign body. We recommend this type of software program for CT scanning of any patient with an injury to the face in which a foreign body is suspected.

Keywords

References

  1. Chung BC, Kim SH, Min DH: Histopathological studies of the foreign body reaction following subdermal implantation of foreign materials into the rabbit. J Korean Soc Plast Reconstr Surg 6: 15, 1979
  2. Paik HW, Choi JW, Chong HK, Lee PK, Ahn ST: Clinical experience of foreign body granuloma in the apex of orbit. J Korean Soc Plast Reconstr Surg 32: 131, 2005
  3. Jeong SH, Shin SH, Park SH, Koo SH: Measurement analytical study of computed tomography of the orbital structure in acute blow-out fracture. J Korean Soc Plast Reconstr Surg 34: 44, 2007
  4. Suh SH, Jang BI, Jung YS, Cho MJ: A case of nasal endoscopic removal of nasocranial metalic foreign body. Korean J Otolaryngol 41: 1485, 1998
  5. Choi BY, Lee SE, Lee WS, Kim SH, Chung DH: A case of penetrating injury into the skull base by a metalic foreign body. Korean J Otolaryngol 39: 1913, 1996
  6. Kim SH, Byeon JH, Rhie JW, Lim P: 2 Cases of penetrating intraorbital injury and complication caused by wood. J Korean Soc Plast Reconstr Surg 23: 833, 1996
  7. Kim IO, Chang KH, Hans MC, Kim CW: An experimental study on the variability of the CT number using phantom models. J Korean Radiol Soc 23: 513, 1987 https://doi.org/10.3348/jkrs.1987.23.4.513
  8. Han TI, Lim JW, Ryu KN, Ko YT, Song MJ, Lee DH, Lee JH: Low density lesion in solid mass on CT: pathologic change and Housfield number. J Korean Radiol Soc 30: 1123, 1994 https://doi.org/10.3348/jkrs.1994.30.6.1123
  9. Zinreich SJ, Miller NR, Aguayo JB, Quinn C, Hadfield R, Rosenbaum AE: Computed tomographic three- dimensional localization and compositional evaluation of intraocular and orbital foreign bodies. Arch Ophthalmol 104: 1477, 1986 https://doi.org/10.1001/archopht.1986.01050220071029
  10. Jin HS, Kim HJ, Han KH: Calcification deposits in nasal silicone implants: regional distribution in relation to surrounding soft tissue. J Korean Soc Plast Reconstr Surg 31: 315, 2004
  11. Kim JH, Kim SH, Kim JH, Kim KS: A case of metallic foreign body retained in the naso-maxillo-ethmoido- orbital complex. Korean J Otolaryngol 47: 177, 2004
  12. Lim JH, Kwak MS: Case report of retained intraorbital metallic foreign body removal. J Korean Ophthalmol Soc 40: 1127, 1999
  13. Lim SJ, Lee JB, Hong YJ: A case of intraorbital foreign body. J Korean Ophthalmol Soc 26: 335, 1985