Investigation on the Internal Flow Characteristics of the Low Specific Speed Centrifugal Pump with Circular Casing

  • Choi, Young-Do (Korea Maritime University, Industry-Academic Cooperation Foundation)
  • Published : 2008.05.31

Abstract

As a suitable volute configuration in the range of low specific speed, circular casing is suggested in this study. The internal flows in a centrifugal pump with the circular and spiral casings are measured by PIV and analyzed by CFD. The results show that the head and efficiency of the pump by a circular casing of very small radius are almost same as those by the spiral casing. Even at the best efficiency point, the internal flow of the pump by circular casing is asymmetric, and vortex and strong secondary flow occurs in the impeller passage. The radial velocity becomes higher remarkably only near the region of the discharge throat. The flow in the impeller outlet is strongly controlled by the circular casing because the velocity distribution almost does not affected by the position of the impeller blades.

Keywords

References

  1. Stepanoff, A. J., "Centrifugal and Axial Flow Pumps," 2nd ed., pp. 69-89, John Wiley and Sons, 1957.
  2. Kurokawa, J., Matsui, J., Kitahora, T., Saha, S. L., Matsumoto, K. and Tsutsui, A., "Performance of Very Low Specific Speed Impeller," Turbomachinery (in Japanese), Vol. 25, No.7, pp. 337-345, 1997.
  3. Kurokawa, J., Matsumoto, K., Yao, W., Matsui, J. and Hiroshi, I., "Study on Optimum Configuration of a Volute Pump of Very Low Specific Speed," Trans. JSME, Series B (in Japanese), Vol. 66, No. 644, pp.1132-1139, 2000. https://doi.org/10.1299/kikaib.66.1132
  4. Matsumoto, K., Kurokawa, J., Matsui, J. and Hiroshi, I., "Performance Improvement and Peculiar Behavior of Disk Friction and Leakage in Very Low Specific Speed Pumps," Trans. JSME, Series B (in Japanese), Vol. 65, No. 640, pp.4027-4032, 1999. https://doi.org/10.1299/kikaib.65.4027
  5. Choi, Y-D., Nishino, K, Kurokawa, J. and Matsui, J., "PIV Measurement of Internal Flow Characteristics of Very Low Specific Speed Semi-open Impeller," Experiments in Fluids, Vol. 37, pp. 617-630, 2004. https://doi.org/10.1007/s00348-004-0838-7
  6. Choi, Y-D., Kurokawa,J., Matsui,J., "Performance and Internal Flow Characteristics of a Very Low Specific Speed Centrifugal Pump," J. Fluids Eng.,Vol. 128, pp. 341-348 , 2006. https://doi.org/10.1115/1.2169815
  7. Choi,Y-D., Kagawa, S. and Kurokawa J., "Influence of Circular Casing on the Performance of Very Low Specific Speed Centrifugal Pump," Journal of Fluid Machinery, Vol. 9, No. 1, pp. 32-39, 2006. https://doi.org/10.5293/KFMA.2006.9.1.032
  8. ANSYS Inc.,"ANSYS-CFX Documentation," Ver. 11, http://www.ansys.com, 2007.

Cited by

  1. Sensitivity analysis of nuclear main pump annular casing tongue blend vol.9, pp.7, 2017, https://doi.org/10.1177/1687814017706599