Analysis of Thermal Characteristics for the Fire Risk Assessment According to Partial Disconnection on the VCTF and IV Electric Wire

VCTF와 IV전선의 반단선에 의한 화재위험성 평가를 위한 열적특성 해석

  • Published : 2008.08.31

Abstract

Many researches on fire risk for normal electric wiring have been pursued in advanced countries such as the USA and Japan, but comparative studies of the partial disconnection and normal state of electric wires have not been conducted. Detection system for the cause of partial disconnection is not developed and prevention countermeasure for electrical fire by the cause is not effective. Therefore, in this paper, partial disconnection characteristics on electric wires were derived and analyzed by experiment and electrical-thermal finite element method(Flux 3D) on the model wires which consist of VCTF(PVC insulated PVC sheathed Cap Tyre Flexible Cord, KS C 3304) and IV(lndoorwire PVC, KS C 3302). VCTF is used in wiring portable electric appliances and the IV is used indoors. Interrelationships between partial disconnection premonitory symptom and current were derived and analyzed by the characteristics based on experiments and thermal analysis for electric wire according to current under normal state and 200% overload state of rated current.

Keywords

References

  1. National Emergency Management Agency, "http://www.nema.go.kr/", (electrical fires statistics), 2007
  2. 東京消防, "新火災調査敎本 (電氣火災編)", pp. 8, 2004
  3. Hong-Seok Oh, "A Study on the Causes and Analysis of electrical fires", Korea Institute of Fire Sce. & Eng., Vol. 16, No. 4, 2002
  4. Korea Electrical Safety Corp., "A Study for Fire Harzard of Electric Wiring and Wire using Electrical equipment", 2001
  5. 金点鎬, "A Study on the Fire Cause Analysis of the HIV", 2004
  6. Chung-Seog Choi, "Analysis of electrical fire type and causes", Electrical journal, Vol. 300, pp. 27-36, 2001
  7. Kil-Mok Shong, Chung-Seog Choi, Dong-Woo Kim, and Hee-Ro Kwak, "Analysis on the characteristics of the standed wire disconnected by bending stress", KIEEME, pp. 464-467, 2003
  8. Young-Seok Kim, Kil-Mok Shong, Dong-Ook Kim, Ki-Yeon Lee, and Chung-Seog Choi, "The analysis of metallurgical structure and arc properties of copper wire due to over-current", KIEEME, pp. 554-555, 2005
  9. Sung-chul Kim, Doo-hyun Kim, "Analysis for the thermal properties of the electrical wire according to overload and Disconnection", Journal of KOSOS, Vol. 22, No. 4, August, 2007
  10. Korean Industrial Standard, "KSC 3304"
  11. Korean Industrial Standard, "KSC 3302"
  12. Michael R, Yenchek "Thermal Modeling of Portable Power Cables", IEEE, 1997
  13. Myoung-Soo, Han, "A Study on the Electrical Fire due to the Weakness of the Contact of Wiring Utensil", Seoul National Unvi. of Tech., Master's thesis, pp. 19, 2004
  14. Jeawoo Tech. Co., "http://www.jeawoo.co.kr", 2007
  15. Korea Institute of Patent Information, "Electric Wiring Monitoring System", US 6801133