참고문헌
- R. M. Brugger, J. A. Shih, and H. B. Liu, “An Epithermal Neutron Beam for Neutron Capture Therapy at the Missouri University Research Reactor,” Nuclear Technology, 98, 322-332 (1992) https://doi.org/10.13182/NT92-A34662
- H. B. Liu, R. M. Brugger, D. C. Rorer, P. R. Tichler, and J. P. Hu, “Design of a High-flux Epithermal Neutron Beam Using 235U Fission Plates at the Brookhaven Medical Research Reactor,” Medical Physics, 21, 1627-1631 (1994) https://doi.org/10.1118/1.597268
- RD Rogus, OK Harling, and JC Yanch, “Mixed Field Dosimetry of Epithermal Neutron Beams Used for Boron Neutron Capture Therapy at the MIRT-II Research Reactor,” Medical Physics, 21, 1611-1625 (1994) https://doi.org/10.1118/1.597267
- IAEA, Current Status of Neutron Capture Therapy, IAEATECDOC-1223, IAEA (2001)
- JC Yanch, XL. Zhou, IE Shefer, and RE Klinkowstein, “Accelerator-based Epithermal Neutron Beam Design for Neutron Capture Therapy,” Medical Physics, 19, 709-721 (1992) https://doi.org/10.1118/1.596815
- J. W. Floyd, W. N. David, et al., “Boron Neutron Capture Therapy (BNCT): Implications of Neutron Beam and Boron Compound Characteristics,” Medical Physics, 26, 1237-1244 (1999) https://doi.org/10.1118/1.598618
- S. Hamidi and M. C. Scott, “BNCT Neutron Beam Characterization Using a Resonance Absorption Filter Method,” Nuclear Instruments and Methods in Physics Research Section A, 476, 99-105 (2002) https://doi.org/10.1016/S0168-9002(01)01399-7
- Sung Ho Park, Chi Young Han, Soon Young Kim, and Jong Kyung Kim, “Use of the CT Images for BNCT Calculation: Development of BNCT Treatment Planning System and Its Applications to Dose Calculation for Voxel Phantoms,” Radiation Protection Dosimetry, 110, 661-667 (2004) https://doi.org/10.1093/rpd/nch235
- CK Wang and BR Moore, “Thick Beryllium Target as an Epithermal Neutron Source for Neutron Capture Therapy,” Medical Physics, 21, 1633-1638 (1994) https://doi.org/10.1118/1.597269
- BA Ludewigt, WT Chu, RJ Donahue, J Kwan, TL Phillips, LL Reginato, and RP Wells, “An Epithermal Neutron Source for BNCT Based on an ESQ-accelerator,” Proceedings of the Topical Meeting on Nuclear Applications of Accelerator Technology, Albuquerque, New Mexico, November 16-20, 1997
- DL Bleuel, RJ Donahue, BA Ludewigt, and J Vujic, “Designing Accelerator-based Epithermal Neutron Beams for Boron Neutron Capture Therapy,” Medical Physics, 25, 1725-1734 (1998) https://doi.org/10.1118/1.598353
- T. E. Blue and J C. Yanch, “Accelerator-based Epithermal Neutron Sources for Boron Neutron Capture Therapy of Brain Tumors,” Journal of Neuro-Oncology, 62, 19-31 (2003) https://doi.org/10.1007/BF02699931
- Deok-jae Lee, Chi Young Han, Sung Ho Park, and Jong Kyung Kim, “An Accelerator-based Epithermal Neutron Beam Design for BNCT and Dosimetric Evaluation Using a Voxel Head Phantom,” Radiation Protection Dosimetry, 110, 655-660 (2004) https://doi.org/10.1093/rpd/nch107
-
CL Lee, XL Zhou, RJ Kudchadker, F Harmon, and YD Harker, “A Monte Carlo Dosimetry-based Evaluation of the
$^{7}{Li(p,n)}^7$ Be Reaction Near Threshold for Accelerator Boron Neutron Capture Therapy,” Medical Physics, 27, 192-202 (2000) https://doi.org/10.1118/1.598884 -
S Zimin and BJ Allen, “Study of Moderator Thickness for an Accelerator-based Neutron Irradiation Facility for Boron Neutron Capture Therapy Using the
$^{7}{Li(p,n)}$ Reaction Near Threshold,” Phys. Med. Biol., 45, 59-67 (2000) https://doi.org/10.1088/0031-9155/45/1/305 -
DA Allen and TD Beynon, “What is the Best Proton Energy for Accelerator-based BNCT Using the
$^{7}{Li(p,n)}^7$ Be Reaction?,” Medical Physics, 27, 1113-1118 (2000) https://doi.org/10.1118/1.598976 - E Bisceglie, P Colangelo, N Colonna, V Paticchio, V Santorelli, and V Variale, 'Production of Epithermal Neutron Beams for BNCT,' Nuclear Instruments and Methods in Physics Research Section A, 476, 123-126 (2002) https://doi.org/10.1016/S0168-9002(01)01406-1
-
WB Howard, SM Grimes, TN Massey, SI Al-Quaraishi, DK Jacobs, CE Brient, and JC Yanch, “Measurement of the Thick Target
$^{9}{Be(p,n)}$ Neutron Energy Spectra,” Nuclear Science and Engineering, 139, 145-160 (2001) -
AA Burlon, AJ Kreiner, S White, JC Yanch, B Blackburn, and D Gierga, “In-phantom Dosimetry Using the
$^{13}{C(d,n)}$ 14N Reaction for BNCT,” Med. Phys., 28, 796-803 (2001) https://doi.org/10.1118/1.1368879 - BW Blackburn, JC Yanch, and RE Klinkowstein, “Development of a High-power Water Cooled Beryllium Target for Use in Accelerator-based Boron Neutron Capture Therapy,” Med. Phys., 25, 1967-1974 (1998) https://doi.org/10.1118/1.598370
-
DL Bleuel and RJ Donahue, “Optimization of the
$^{7}{Li(p,n)}$ Proton Beam Energy for BNCT Application,” LBL-37983, Lawrence Berkeley National Laboratory (1996) - Shane Park, Hyeong Min Joo, Byeong Ill Jang, Gyoodong Jeun, Jong Kyung Kim, and Jong Seo Chai, “Thermally Optimized Lithium Neutron Producing Target Design for Accelerator-based BNCT,” Proceedings of the 12th International Symposium on Neutron Capture Therapy for Cancer, Kagawa, Japan, October 9-13, 2006
- BW Blackburn and JC Yanch, “Liquid Gallium Cooling of a High-power Beryllium Target for Use in Accelerator Boron Neutron Capture Therapy (ABNCT),” Proceedings of the 8th Workshop on Targetry and Target Chemistry, Missouri, USA, June 23-26, 1999
- N. C. Christopher, Greenb Stuart, J. Masona Anna, et al., “In-phantom Characterisation Studies at the Birmingham Accelerator-Generated Epithermal Neutron Source (BAGINS) BNCT Facility,” Applied Radiation and Isotopes, 61, 733- 738 (2004) https://doi.org/10.1016/j.apradiso.2004.05.057
- Swanson Analysis Systems, ANSYS - Engineering Analysis System. Theoretical Manual (for ANSYS Revision 4.4), Swanson Analysis Systems, 1989
- Sang Hoon Jung, Chi Young Han, Soon Young Kim, Jong Kyung Kim, Min Goo Hur, Jong-Seo Chai, Yong Kyun Kim, and Jang Ho Ha, “Measurement of Neutron Spectrum and Yield for the Lithium Target System in Accelerator- Based BNCT,” Proceeding of the Korean Nuclear Society Spring Meeting, Jeju, Korea, May 26-27, 2005
- Shane Park, Gyoo Dong Jeun, and Jong Kyung Kim, “A Development of Thermally Optimized of Lithium Target Design for Accelerator-Based BNCT,” The Third International Symposium on Radiation Safety and Detection Technology (ISORD-3), Taiyuan, China, July 27-28, 2005
- Sang Hoon Jung, Chi Young Han, Soon Young Kim, and Jong Kyung Kim, “Research on Accelerator-Based BNCT in Hanyang University,” The Third International Symposium on Radiation Safety and Detection Technology (ISORD- 3), Taiyuan, China, July 27-28, 2005
- Fluent Inc., “FLUENT 6.0 User Guide,” Fluent Inc. (2001)
- F. Y. Hsu, C. J. Tung, J. C. Chen, Y. L. Wang, H. C. Huang, and R. G. Zamenhof, “Dose-rate Scaling Factor Estimation of THOR BNCT Test Beam,” Applied Radiation and Isotopes, 61, 881-885 (2004) https://doi.org/10.1016/j.apradiso.2004.05.048
- Cornelis P. Raaijmakers, Iain A. Bruinvis, Eric L. Nottelman, and Ben J. Mijnheer, “A Fast and Accurate Treatment Planning Method for Boron Neutron Capture Therapy,” Radiotherapy and Oncology, 46, 321-332 (1998) https://doi.org/10.1016/S0167-8140(97)00183-7
- B. J. Albertson, T. E. Blue, and J. Niemkiewicz, “An Investigation on the Use of Removal-Diffusion Theory for BNCT Treatment Planning: A Method for Determining Proper Removal-Diffusion Parameters,” Medical Physics, 28, 1898-1904 (2001) https://doi.org/10.1118/1.1386424
- I. Auterinen and P. Hiismaki, “Design of an Epithermal Neutron Beam for the TRIGA Reactor at Otaniemi,” Proceedings of the CLINCT BNCT Workshop, Helsinki, Finland, May 14-24 1993
- V. Giusti, “Neutron sources for BNCT: a General Review,” Proceedings of the International Workshop on Neutron Capture Therapy: State of the Art and 3rd Young Members Neutron Capture Therapy Meeting, Pisa, Italy, Nov. 28 - Dec. 2, 2003.
- O. E. Kononov, V. N. Kononov, M. V. Bokhovko, V. V. Korobeynikov, A. N. Soloviev, A. S. Sysoev, I. A. Gulidov, W. T. Chu, and D. W. Nigg, “Optimization of an Accelerator-based Epithermal Neutron Source for Neutron Capture Therapy,” Applied Radiation and Isotopes, 61, 1009-1013 (2004) https://doi.org/10.1016/j.apradiso.2004.05.028
- A.A. Burlon and A.J. Kreiner, “A Comparison between a TESQ Accelerator and a Reactor as a Neutron Sources for BNCT,” Nuclear Instruments and Methods in Physics Research Section B, 266, 763-771 (2008) https://doi.org/10.1016/j.nimb.2008.01.004
- A. J. Kreiner, J. W. Kwan, et al., “Tandem-ESQ for Accelerator-based BNCT,” Proceedings of the 12th International Symposium on Neutron Capture Therapy for Cancer, Kagawa, Japan, October 9-13, 2006
- K. Tanaka, et al., “Irradiation Characteristics of BNCT Using Near-threshold 7Li(p,n)7Be Direct Neutrons: Application to Intra-operative BNCT for Malignant Brain Tumours,” Phys. Med. Biol., 47, 3011-3032 (2002) https://doi.org/10.1088/0031-9155/47/16/315
-
K. Tanaka, T. Kobayashi, G. Bengua, Y. Nakagawa, S. Endo, and M. Hoshi, “Characteristics of BDE Dependent on
$^{10}B$ Concentration for Accelerator-based BNCT Using Near-threshold$^{7}{Li(p,n)}^7{Be}$ Direct Neutrons,” Applied Radiation and Isotopes, 61, 875-879 (2004) https://doi.org/10.1016/j.apradiso.2004.05.047 - S. Yonai, T. Itoga, M. Baba, T. Nakamura, H. Yokobori, and Y. Tahara, “Benchmark Experiments for Cyclotronbased Neutron Source for BNCT, Applied Radiation and Isotopes, 61, 997-1001 (2004) https://doi.org/10.1016/j.apradiso.2004.05.025
- S. Yonai, T. Aoki, T. Nakamura, H. Yashima, M. Baba, H. Yokobori, and Y. Tahara, “Feasibility Study on Epithermal Neutron Field for Cyclotron-based Boron Neutron Capture Therapy,” Med. Phys., 30, 2021-2031 (1998) https://doi.org/10.1118/1.1587431
- D. Pelowitz (Ed.), “MCNPX User's Manual Version 2.5.0,” LA-CP-05-0369, Los Alamos National Laboratory (2005)
- D. A. Allen and T. D. Beynon, “A Design Study for an Accelerator Based Epithermal Neutron Beam for BNCT,” Phys. Med. Biol., 40, 807-821(1995) https://doi.org/10.1088/0031-9155/40/5/007
-
Kyung-O Kim, Sang Hoon Jung, Soon Young Kim, Gi- Dong Kim, and Jong Kyung Kim, “Performance Evaluation of a Beam-shaping Assembly for Accelerated-BNCT Using the Neutron Generation Experiment of
$^{7}{Li(p,n)}^7{Be}$ Reaction,” Journal of Nuclear Science and Technology, Supplement 5, 143-146 (2008) - Kyung-O Kim, Soon Young Kim, and Jong Kyung Kim, “A Feasibility Study on a Dual-beam Port Assembly for Accelerator-Based Boron Neutron Capture Therapy,” Journal of Nuclear Science and Technology, Supplement 5, 197-200 (2008)
-
Kyung-O Kim, Jong Kyung Kim, and Soon Young Kim, “Optimized Therapeutic Neutron Beam for Acceleratorbased BNCT by Analyzing the Neutron Angular Distribution from
$^{7}{Li(p,n)}^7{Be}$ Reaction,” Applied Radiation and Isotopes, In Press, Available Online 14 February (2009) - S. J. Gonzalez, G. A. Santa Cruz, W. S. Kiger III, M. R. Palmer, P. M. Busse, and R. G. Zamenhof, “NCTPlan, the New PC version of MacNCTPlan: Improvements and Verification of a BNCT Treatment Planning System,” Proceedings of the 10th International Symposium on Neutron Capture Therapy for Cancer, Essen, Germany, September 8-13, 2002
- D. W. Nigg, C. A. Wemple, D. E. Wessol, and F. J. Wheeler, “SERA, An Advanced Treatment Planning System for Neutron Therapy and BNCT,” Transactions of the American Nuclear Society, 80, 66-68 (1999)
- Sang Hoon Jung, Ik Soo Choi, Sung Ho Park, Kyung-O Kim, and Jong Kyung Kim, “A New GUI Based Patient- Specific Treatment Planning System for Boron Neutron Capture Therapy,” Journal of Nuclear Science and Technology, Supplement 5, 201-204 (2008)
-
Sang Hoon Jung, Sung Ho Park, Ik Soo Choi, Jong Kyung Kim, Sang Min Yoon, Eun Kyung Choi, Seung Do Ahn, Sang-wook Lee, and Jong Hoon Kim, “A Treatment Planning Study on Glioblastoma Multiforme with Different Techniques Using Boron Neutron Capture Therapy, 3D Conformal Radiotherapy, and Intensity Modulated Radiotherapy,” the
$6^{th}$ International Conference on Isotopes, Seoul, Korea, May 12-16, 2008
피인용 문헌
- Design study and heat transfer analysis of a neutron converter target for medical radioisotope production vol.299, pp.2, 2014, https://doi.org/10.1007/s10967-013-2637-1
- Neutrons against cancer vol.45, pp.5, 2014, https://doi.org/10.1134/S1063779614050049
- Determination of the thermal and epithermal neutron sensitivities of an LBO chamber vol.56, pp.3, 2017, https://doi.org/10.1007/s00411-017-0700-y
- Characteristics of a heavy water photoneutron source in boron neutron capture therapy vol.37, pp.7, 2013, https://doi.org/10.1088/1674-1137/37/7/078201
- Be reaction for treatment of deep-seated brain tumors by BNCT vol.38, pp.10, 2014, https://doi.org/10.1088/1674-1137/38/10/108203