DOI QR코드

DOI QR Code

Earthquake Resistance of Beam-Column Connection of Precast Concrete U-Shaped Shell Construction

프리캐스트 콘크리트 U형 쉘 공법 보-기둥 접합부의 내진성능

  • Received : 2010.04.26
  • Accepted : 2010.09.28
  • Published : 2010.12.31

Abstract

An experimental study was performed to investigate the earthquake resistance of the beam-column connections as a part of a precast concrete moment-resisting frame that uses precast concrete U-shaped shells for the beams. Five full-scale precast concrete specimens and one conventional monolithic concrete specimen were tested under cyclic loading. The parameters for this test were the reinforcement ratio, stirrup spacing, and end-strengthening details of the precast beam shell. The test results showed that regardless of the test parameters, the precast concrete beam-column connections showed good load-carrying capacity and deformation capacity, which were comparable to those of conventional monolithic concrete specimen. However, at large deformations, the beam-column connections of the precast concrete specimens were subjected to severe strength degradation due to diagonal shear cracks and the bond-slip of re-bars at the joint region. For this reason, the energy dissipation capacity and stiffness of the precast concrete specimens were significantly less than those of the cast-in-place specimen.

이 연구에서는 프리캐스트 콘크리트(PC) U형 쉘을 사용하는 PC 모멘트 골조의 일부인 보-기둥 내부접합부의 내진성능을 평가하기 위하여 실험연구를 수행하였다. 5개의 PC 보-기둥 내부접합부와 1개의 현장타설 콘크리트 보-기둥 내부접합부를 실물 크기로 제작하여 반복가력 실험을 수행하였다. 주요 변수는 보 주철근비, 보 전단철근 간격, U형 PC쉘과 기둥 모서리의 보강철물 설치 유무이다. 실험 결과, 변수에 관계없이 PC 보-기둥 접합부는 현장타설 콘크리트 보-기둥 접합부와 비교하여 유사한 하중재하능력, 연성능력을 나타냈다. 그러나 주기 하중동안 PC 보-기둥 접합부는 보-기둥 이음부에서 보 주철근의 부착파괴로 인한 미끄러짐 변형과 대각방향의 전단균열로 인하여 심한 강도 저하를 나타냈고, 이로 인해 현장타설 콘크리트 보-기둥 접합부보다 접합부의 강성과 에너지소산능력이 감소되었다.

Keywords

References

  1. Englekirk, R. E., “Development and Testing of a Ductile Connector for Assembling Precast Concrete Beams and Columns,” PCI Journal, Vol. 40, No. 2, 1995, pp. 36-51. https://doi.org/10.15554/pcij.03011995.36.51
  2. Mast, R. F., “A Precast Concrete Frame System for Seismic Zone Four,” PCI Journal, Vol. 37, No. 1, 1992, pp. 50-64. https://doi.org/10.15554/pcij.01011992.50.64
  3. Bhatt, P. and Kirk, D. W., “Test on an Improved Beam Column Connection for Precast Concrete,” ACI Journal, Vol. 82, No. 6, 1985, pp. 834-843.
  4. Priestley, M. J. N. and MacRae, G. A., “Seismic Tests of Precast Beam-to-Column Joint Subassemblages with Unbonded Tendons,” PCI Journal, Vol. 41, No. 1, 1996, pp. 64-81.
  5. Park, R. and Bull, D. K., “Seismic Resistance of Frames Incorporating Precast Prestressed Concrete Beam Shells,” PCI Journal, Vol. 31, No. 4, 1986, pp. 54-93. https://doi.org/10.15554/pcij.07011986.54.93
  6. 김승훈, 문정호, 이리형, “철근이음형 프리캐스트 콘크리트 보-기둥 내부 접합부의 구조적 거동에 관한 실험적 연구,” 대한건축학회 논문집 구조계, 20권, 10호, 2004, pp. 53-61.
  7. Park, H. and Eom, T., “A Simplified Method for Estimating the Amount of Energy Dissipated by Flexure-Dominated Rein-forced Concrete Members for Moderate Cyclic Deformations,” Earthquake Spectra, Vol. 22 No. 3, 2006, pp. 1351-1363.