Abstract

The objective of the present study is to investigate the dividing two-phase flow in a horizontal micro T-junction with the same rectangular cross section, $800\;{\mu}m{\times}800\;{\mu}m$, experimentally. Air and water were used as the test fluids. The superficial velocity ranges of air and water were 15~20 m/s and 0.11~0.2 m/s, respectively. Dividing flow characteristics at the micro T-junction are different from those at the larger T-junctions (5~10 mm in hydraulic diameter). Compared with the results of previous works related with the T-junction with mini cross sections (about 5 mm), for lower range of gas separation, the fraction of the liquid separated through the branch decreases for the fixed fraction of the gas separation. But for higher range of gas separation, higher liquid separation could be found.

Keywords

References

  1. Stacey, T., Azzopardi, B. J. and Conte, G., 2000, The split of annular two-phase flow at a small diameter T-junction, Int. J Multiphase Flow, Vol. 26, pp. 845-856. https://doi.org/10.1016/S0301-9322(99)00051-8
  2. Hong, K. C., 1978, Two phase flow splitting at a pipe tee, J. Pet. Technol., pp. 290-296.
  3. Lee, J. K. and Lee, S. Y., 2001, Dividing two-phase annular flow within a small vertical rectangular channel with a horizontal branch, Proc. 3rd International Conference on Compact Heat Exchangers and Enhancement Technology for the Process Industries, Davos, Switzerland, pp. 361-368.
  4. Mak, C. Y., Omebere-Iyari, N. K. and Azzopardi, B. J., 2006, The split of vertical two-phase flow at a small diameter T-junction, Chem. Eng. Sci., Vol. 61, pp. 6261-6272. https://doi.org/10.1016/j.ces.2006.05.039
  5. Lim, J. S., 2008, An experimental study on dividing two-phase plug flow at a mini T-junction, M. S. thesis, Korea Advanced Institute of Science and Technology.
  6. Yang, C. Y and Shieh, C. C., 2000, Flow pattern of air-water and two-phase R-134a in small circular tubes, Int. J Multiphase Flow, Vol. 27, pp. 1163-1177.
  7. Azzopardi, B. J., 1984, The effect of side arm diameter on two phase flow split at a T junction, Int. J. Multiphase Flow, Vol. 10, pp. 509-512. https://doi.org/10.1016/0301-9322(84)90059-4
  8. Shoham, O., Brill, J. P. and Taitel, Y, 1987, Two-phase Flow Splitting in a Tee Junction-Experiment and Modelling, Chem. Eng. Sci., Vol. 42, pp. 2667-2676. https://doi.org/10.1016/0009-2509(87)87017-3