ORIGINAL ARTICLE - 임플란트 종류 및 식립부위에 따른 안정성에 대한 RFA 분석

ORIGINAL ARTICLE - Analysis of RFA related to stabilities by types and areas of dental implants

  • 이희용 (부천사과나무치과의원) ;
  • 박민주 (부천사과나무치과의원) ;
  • 조현재 (서울대학교 치의학대학원 예방치학교실) ;
  • 유기준 (부천사과나무치과의원) ;
  • 하정은 (서울대학교 치의학대학원 예방치학교실) ;
  • 백대일 (서울대학교 치의학대학원 예방치학교실) ;
  • 배광학 (서울대학교 치의학대학원 예방치학교실)
  • Yi, Hee-Yong (Apple Tree Dental Clinic) ;
  • Park, Min-Ju (Apple Tree Dental Clinic) ;
  • Cho, Hyun-Jae (Dept. of Preventive and Public Health Dentistry, School of Dentistry, Seoul National University) ;
  • Yu, Ki-Jun (Apple Tree Dental Clinic) ;
  • Ha, Jung-Eun (Dept. of Preventive and Public Health Dentistry, School of Dentistry, Seoul National University) ;
  • Baek, Dae-Il (Dept. of Preventive and Public Health Dentistry, School of Dentistry, Seoul National University) ;
  • Bae, Gwang-Hak (Dept. of Preventive and Public Health Dentistry, School of Dentistry, Seoul National University)
  • 투고 : 2011.12.08
  • 심사 : 2011.12.23
  • 발행 : 2012.01.01

초록

Objective : This research compared stabilities between two types of dental implant ($SLA^{TM}$, Institut Straumann AG, Waldenburg, Switzerland and $SSII^{TM}$, Osstem co, Busan, Korea) using Osstell Mentor (Integration Diagnostics AB, Goteborg, Sweden) considering surgery methods, surgery area, diameter of implant, systemic disease, and smoking for obtaining prognosis information when installing fixture of dental implant. Materials & Methods : 206 implants of 131 patients taken by resonance frequency analysis (RFA) were determined as a final sample. Dental implants were installed as protocol of supplier by a excellent dentist who had 10 years experience about dental implants. Before connecting abutments (3 months after installation of fixture), RFA were measured twice for buccal and lingual direction to obtain average value. Results : Dental implants at mandible showed significantly higher stabilities significantly than at maxilla (p<0.001). Diameter 4.8 implants had also higher stabilities than diameter 4.1 in case of $SLA^{TM}$ implants (p<0.001). $SLA^{TM}$ implants showed more excellent stabilities than $SSII^{TM}$ implants, especially at posterior area of mandible (p=0.045) and premolar area of maxilla (p=0.032). Conclusions : This research revealed higher stabilities of $SLA^{TM}$ implants than $SSII^{TM}$ implant, especially at posterior area of mandible (p=0.045) and premolar area of maxilla (p=0.032).

키워드

참고문헌

  1. Sennerby L, Meredith N. Implant stability measurements using resonance frequency analysis : biological and biomechanical aspects and clinical implications. Periodonto 2000. 2008;47:51-66. https://doi.org/10.1111/j.1600-0757.2008.00267.x
  2. Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont. 1998;11(5) :491-501.
  3. Rodrigo D, Aracil L, Martin C, Sanz M. Diagnosis of implant stability and its impact on implant survival : a prosective case series study. Clin Oral Implants Res. 2010;21(3):255-261. https://doi.org/10.1111/j.1600-0501.2009.01820.x
  4. Friberg B, Senner by L, Lin den B, Grondahl K, Lekholm U. Stabiluty Measurements of noe-stage Branemark implants during healing in mandibles. A clinical resonance frequency analysis study. Int J Oral Maxillofac Surg. 1999;28(4):266-272. https://doi.org/10.1016/S0901-5027(99)80156-8
  5. Szmukler-Moncler S, Salama H, Reingewirtz y, Dubruille JH. Timing of loading and effect of micromotion on bone-dental implant interface review of experimental literature. J Biomed Mater Res. 1998;43(2):192-203. https://doi.org/10.1002/(SICI)1097-4636(199822)43:2<192::AID-JBM14>3.0.CO;2-K
  6. Sykaras N, Triplett RG, Nunn ME, lacopio AM, Opperman LA. Effect of recombinant human bone morphogenetic protein-2 on bone regerneration and osseointegration of dental implants. Clin Oral Implants res. 2001;12(4):339-49). https://doi.org/10.1034/j.1600-0501.2001.012004339.x
  7. Albreksson T, Jacobsson M. Bone-metal interface in osseointegration. J Prosthet Dent. 1987;57:597-607). https://doi.org/10.1016/0022-3913(87)90344-1
  8. Carlsson L, Rostlund T, Albrektsson B, Albrektsson T. Removal torques for polished and rough titanium implants. Int J Oral Maxillofac Implants. 1988;3(1) :21-24.
  9. Kim JM, Kim SJ, Han I, Shin SW, Ryu JJ. A camparison of the implant stability among various implant systems: clinical study. J Adv Prosthodont. 2009 Mar;1(1):31-36. https://doi.org/10.4047/jap.2009.1.1.31
  10. Froberg KK, Lindh C, Ericsson I. Immediate loading of Branemark System Implants: a comparison between TiUnite and turned implants placed in the anterior mandible. Clin Implant Dent Relat Res. 2006 ;8(4):187-197. https://doi.org/10.1111/j.1708-8208.2006.00017.x
  11. AI-Khaldi N, Sleeman D, Allen F. Stability of dental imlants in grafted bone in the anterior maxilla longitudinal study. Br J Oral Maxillofac Surg 2011 Jun;49(4):319-323. https://doi.org/10.1016/j.bjoms.2010.05.009
  12. 오준호, 장문택, Resonance Frequency Analysis(RFA)를 이용한 임플란트 종류간의 초기 안정성 비교. 대한치주과학회지. 2008;39(3):529-534.
  13. 이진숙, 상악동저거상 이종골이식과 동시에 식립한 비매립형 임플란트의 초기 안정성에 관한 공명진동수 분석(RFA), 이화여대 임상치의학대학원 2008.
  14. Sui YT, Jonsson J, Yoon GS, Johansson C. Resonance frequency measurements in vivo and related surface properties of magnesiumincorporated, micropatterned and magnesiumincoporated TiUnite, Osseotite, SLA, TiOblast implants. Clin Oral Implants Res. 2009 Oct;20(10):1146-1155. https://doi.org/10.1111/j.1600-0501.2009.01767.x
  15. Rabel A, Kohler SG, Schmidt-Westhausen AM. Clinical study in the primary stability of two dental implant systems with resonance frequency analysis. Clin Oral Investig. 2007 Sep;11(3):257-265. https://doi.org/10.1007/s00784-007-0115-2
  16. Chong L, Khocht A, Suzuki JB, Gaughan J. Effect of implant design on initial stability of tapered implants. J Oral Implantol. 2009;35(3):130-135. https://doi.org/10.1563/1548-1336-35.3.130
  17. Sim CP, Lang NP. Factors influencing resonance frequency analysis assessed by Osstell mentor during implant tissue integration: 1. Instrumenet positioning, bone structure, implant length. Clin Oral Implants Res. 2010 Jun;21(6):598-604. https://doi.org/10.1111/j.1600-0501.2009.01878.x
  18. Han J, Lulic M, Lang NP. Factors influencing resonance frequency analysis assessed by Osstell mentor during implant tissue integration: 2. Implant surface modifications and implant diameter. Clin Oral Implants Res. 2010 Jun;21(6):605-611. https://doi.org/10.1111/j.1600-0501.2009.01909.x
  19. Ohta K, Takechi M, Minami M, Shigeishi H, Hiraoka M, Nishimura M, Kamata N. Influence of factors related to implant stability detected by wireless resonance frequency analysis device. J Oral Rehabil. 2010 Feb;37(2):131-137. https://doi.org/10.1111/j.1365-2842.2009.02032.x
  20. Valderrama P, Oates TW, Jones AA, Simpson J, Schoolfield JD, Cochran DL. Evaluation of two different resonanace frequency devices to detect implant stability : A Clinical trial. J Periodontol. 2007;78(2):262-272. https://doi.org/10.1902/jop.2007.060143
  21. Oh JS, Kim SG, Lim SC, Ong JL A comparative study of two noninvasive techniques to evaluate implant stability : Periotest and Osstell Mentor. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2009;107(4):513-518. https://doi.org/10.1016/j.tripleo.2008.08.026
  22. Lachmann S, Jager B, Axmann D, Gomex-Roman G, Groten M, Weber H. Resonance Frequency analysis and damping capacity assessment, Part 1 : an in vitro study on measurement reliability and a methodof comparison in the determination of primary dental implant stability. Clin Oral Implants Res. 2006 Feb;17(1):75-79. https://doi.org/10.1111/j.1600-0501.2005.01173.x
  23. Zix J, Hug S, Kessler-Liechti G, Mericske-Stern R. Measurement of Dental Implant Stability by Resonance frequency analysis and damping capacity assessment : Comparison of both techniques in a clinical trial. Int J Oral Maxillofac Implants. 2008;23(3):525-530.
  24. Winter W, Mohrle S, Holst S, Karl M. Parameters of Implants stability measurements based on resonance frequency and damping capacity : A comprative finite element analysis. Int J Oral Maxillofac Implants. 2010;25(3):532-539.
  25. Guier AU, Sumer M, Duran I, Ozen Sandikci E, Telcioglu NT. RESONANCE FREQUENCY ANALYSIS OF 208 STRAUMANN DENTAL IMPLANTS DURING THE HEALING PERIOD. J Oral Implantol. 2011 Nov 21.
  26. 이상윤, 치과 임플란트 산업의 글로벌 경쟁력 확보 방안에 관한 연구 : 아시아 태평양지역을 중심으로, 한양대 산업경영디자인대학원 2009
  27. Mombelli A, Cionca N. SystemiC diseases affecting osseointegration therapy. Clin Oral Implants Res. 2006;17(2):97-103. https://doi.org/10.1111/j.1600-0501.2006.01354.x
  28. Alsaadi G, Quirynen M, Koma ' rek A, van Steenberghe D. Impact of local and systemic factors on the incidence of oral implant failures, up to abutment connection. J Clin Periodontol. 2007;34(7):610-617 https://doi.org/10.1111/j.1600-051X.2007.01077.x
  29. Huang HM, Lee SY, Yeh CY, Lin CT. Resonance frequency assessment of dental implant stability with various bone qualities : a numerical approach. Clin Oral Implants Res. 2002;13(1):65-74. https://doi.org/10.1034/j.1600-0501.2002.130108.x
  30. Huang HM, Chiu CL, Yeh CY, Lin LH, Lee SY. Early detection of implant healing process using resonance frequency analysis. Clin Oral Implants Res. 2003a;14(4) 437-443. https://doi.org/10.1034/j.1600-0501.2003.00818.x
  31. Huang HM, Chiu CL, Yeh CY, Lee SY. Factors influencing the resonance frequency of dental implants. J Oral Maxillo fac Surg. 2003b;61(10):1184-1188. https://doi.org/10.1016/S0278-2391(03)00680-3
  32. Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Implants Res. 1996 ;7(3):261-7. https://doi.org/10.1034/j.1600-0501.1996.070308.x