DOI QR코드

DOI QR Code

유동 덮개 형상이 축소 APR+ 내부 유동분포에 미치는 영향에 대한 수치해석

Numerical Analysis for the Effect of Flow Skirt Geometry on the Flow Distribution in the Scaledown APR+

  • 이공희 (한국원자력안전기술원 안전해석평가실) ;
  • 방영석 (한국원자력안전기술원 안전해석평가실) ;
  • 우승웅 (한국원자력안전기술원 안전해석평가실) ;
  • 김도형 (앤플럭스(주)) ;
  • 강민구 (앤플럭스(주))
  • 투고 : 2013.01.25
  • 발행 : 2013.05.10

초록

In this study, in order to examine the applicability of computational fluid dynamics with the porous model to the analysis of APR+ (Advanced Power Reactor Plus) internal flow, simulation was conducted with the commercial multi-purpose computational fluid dynamics software, ANSYS CFX V.14. In addition, among the various reactor internals, the effect of flow skirt geometry on reactor internal flow was investigated. It was concluded that the porous model for some reactor internal structures could adequately predict the hydraulic characteristics inside the reactor in a qualitative manner. If sufficient computation resource is available, the predicted core inlet flow distribution is expected to be more accurate, by considering the real geometry of the internal structures, especially located in the upstream of the core inlet. Finally, depending on the shape of the flow skirt, the flow distribution was somewhat different locally. The standard deviation of the mass flow rate (${\sigma}$) for the original shape of flow skirt was smaller, than that for the modified shape of flow skirt. This means that the original shape of the flow skirt may give a more uniform distribution of mass flow rate at the core inlet plane, which may be more desirable for the core cooling.

키워드

참고문헌

  1. Lee, K. B., Im, I. Y., Lee, B. J., and Kuh, J. E., 1991, YGN 3&4 reactor flow model test, J. Korean Nuclear Society, Vol. 23, pp. 340-351.
  2. Euh, D. J., Kim, K. H., Youn, J. H., Bae, J. H., Chu, I. C., Kim, J. T., Kang, H. S., Choi, H. S., Lee, S. T., and Kwon, T. S., 2012, A flow and pressure distribution of APR+ reactor under the 4-pump running conditions with a balanced flow rate, Nuclear Engineering and Technology, Vol. 44, pp. 735-744. https://doi.org/10.5516/NET.02.2012.715
  3. Rohde, U., Hohne, T., Kliem, S., Hemstrom, B., Scheuerer, M., Toppila, T., Aszodi, A., Boros, I., Farkas, I., Muhlbauer, P., Vyskocil, L., Klepac, J., Remis, J., and Duryi, T., 2007, Fluid mixing and flow distribution in a primary circuit of a nuclear pressurized water reactor-validation of CFD codes, Nuclear Engineering and Design, Vol. 237, pp. 1639-1655. https://doi.org/10.1016/j.nucengdes.2007.03.015
  4. Menter, F., 2001, CFD best practice guidelines for CFD code validation for reactor safety applications, ECORA CONTRACT $N^{\circ}$ FIKS-CT-2001-00154.
  5. ANSYS CFX, Version 14.0, ANSYS Inc.
  6. APR+ Standard Safety Analysis Report, Korea Hydro and Nuclear Power Co, LTD.
  7. Kwon, T. S., Kim, K. H., Chu, I. C., and Euh, D. J., 2012, CFD benchmark calculation for the 1/5-scale ACOP core flow test, Transactions of the Korean Nuclear Society Autumn Meeting, Gyeongju, Korea.
  8. ANSYS CFX-Solver Modeling Guide, 2011, ANSYS Inc.
  9. Lee, G. H., Bang, Y. S., and Woo, S. W., 2012, Numerical analysis of turbulent flow in a staggered tube bundle by applying CFD best practice guideline, Transactions of the Korean Society of Mechanical Engineer Autumn Meeting, Changwon, Korea.
  10. Bieder, U. and Graffard, E., 2008, Qualification of the CFD code TRIO_U for full scale reactor applications, Nuclear Engineering and Design, Vol. 238, pp. 671-679. https://doi.org/10.1016/j.nucengdes.2007.02.040
  11. Lee, G. H., Bang, Y. S., and Woo, S. W., 2012, Performance assessment of turbulence models for the prediction of moderator thermal flow inside CANDU calandria, Transactions of the KSME(B), Vol. 36, No. 3, pp. 363-369. https://doi.org/10.3795/KSME-B.2012.36.3.363