DOI QR코드

DOI QR Code

Application of Direct Analysis Method Considering Initial Imperfection Limitation

초기변형 허용값을 고려한 직접해석법 적용

  • Kim, Hee Dong (Department of Architecture, Inha Technical College)
  • 김희동 (인하공업전문대학 건축과)
  • Received : 2013.06.07
  • Accepted : 2013.07.30
  • Published : 2013.10.27

Abstract

As the first step to suggest effective ways of using direct analysis method considering current situations of construction fields in Korea, analytical approach is used to verify direct analysis method which adapts initial imperfection limitation of Korean specification of building construction. The main analytical variables are size of frames, axial load ratio, axial load distribution, value of notional loads, location of notional loads, and applied method of notional loads. The results show that the use of initial imperfection limitation of Korean specification, L/700 is suitable, and the recommendable method to use direct analysis method is applied notional loads based on L/700 as minimum lateral load at each story, even if B2 is less than 1.5 and lateral loads exist.

국내 현실을 고려한 직접해석법 적용 방안의 제안을 위한 기초 연구로 국내의 강구조물 제작 및 설치시 적용되는 초기변형 허용값을 반영한 직접해석법 적용의 타당성을 해석적으로 평가하였다. 해석의 주요 변수로는 골조의 규모, 축력비, 축력분포, 가상하중 크기, 가상하중 가력 위치, 최소수평하중 개념 적용 여부 등을 적용하였다. 수치해석적 연구 결과 국내 초기변형 허용값인 L/700의 적용은 타당한 것으로 나타났으며, 이를 위한 방안으로 초기변형 허용값 L/700에 근거한 가상하중을 B2계수의 결과가 1.5 이하이고 수평하중이 존재하는 경우에라도 수평하중과 가상하중간에 최소수평하중 개념을 이용하여 층수평하중 형태로 가력하는 방법을 제안하였다.

Keywords

References

  1. 국토해양부(2009) 건축구조기준. 국토해양부, 대한민국. Ministry of Land, Infrastructure and Transport (2009) Korea Building Codes, Ministry of Land, Infrastructure and Transport, Korea (in Korean).
  2. 김희동(2010) 골조 안정성 평가를 위한 직접해석법 적용 방법에 따른 영향, 한국강구조학회논문집, 한국강구조학회, 제 22권, 제4호, pp.293-303. Kim, H.D (2010) The influence of the application methods of direct analysis method for the evaluation of frame stability, Journal of Korean Society of Steel Construction, KSSC, Vol. 22, No. 4, pp. 293-303 (in Korean).
  3. 김희동(2010) 하중증폭계수를 적용한 비대칭 비가새 골조 2차 해석 평가, 한국강구조학회논문집, 한국강구조학회, 제22권, 제1호, pp.87-97. Kim, H.D (2010) Evaluation of the Second Order Analysis of Asymmetric Unbraced Frame by using Load Amplification Factor, Journal of Korean Society of Steel Construction, KSSC, Vol. 22, No. 1, pp.87-97 (in Korean).
  4. 김희동, 이명재(2009) 하중증폭계수를 적용한 비가새 골조 2차 해석 평가, 한국강구조학회논문집, 한국강구조학회, 제21권, 제6호, pp.627-636. Kim, H.D. and Lee, M.J. (2009) Evaluation of the Second Order Analysis of Unbraced Frame by using load amplification factor, Journal of Korean Society of Steel Construction, KSSC, Vol. 21, No. 6, pp.627-636 (in Korean).
  5. AISC (2010) Specification for Structural Steel Buildings, AISC, USA.
  6. 건설교통부(2006) 건축공사표준시방서, 건설교통부, 대한민국. Ministry of Land, Infrastructure and Transport (2006) Korea Building Codes, Ministry of Land, Infrastructure and Transport, Korea (in Korean).
  7. Kim, H.D. and Lee, M.J. (2009) Experimental Investigation of the P-$\Delta$ Effect and Factor B2 of Low-rise Unbraced Steel Frames, International Journal of Steel Structures, Vol. 9. No. 2, KSSC, Korea.
  8. McGuire, W., Gallagher, R.H., and Ziemian, R.D. (1999) Matrix Structural Analysis, With MASTAN2, Weily, USA.