DOI QR코드

DOI QR Code

Image Analysis of a Lateral Flow Strip Sensor for the Detection of Escherichia coli O157:H7

  • Received : 2013.10.05
  • Accepted : 2013.11.20
  • Published : 2013.12.01

Abstract

Purpose: This study was performed to develop a lateral flow strip sensor for the detection of pathogenic Escherichia coli O157:H7 in various samples. Also, feasibility of using an image analysis method to improve the interpretation of the strip sensor was evaluated. Methods: The lateral flow strip sensor has been fabricated based on nitrocellulose lateral-flow membrane. Colloidal gold and E. coli O157:H7 antibodies were used as a tag and a receptor, respectively. Manually spotted E. coli O157:H7 antibody and anti-mouse antibody on nitrocellulose membrane were used as test and control dots, respectively. Feasibility of the lateral flow strip sensor to detect E. coli O157:H7 were evaluated with serially diluted E. coli O157:H7 cells in PBS or food samples. Test results of the lateral flow strip sensor were measured with an image analysis method. Results: The intensity of the test dot started to increase with higher concentration of the cells were introduced. The sensitivities of the sensor were both $10^4$ CFU/mL Escherichia coli O157:H7 spiked in PBS and in chicken meat extract, respectively. Conclusions: The lateral flow strip sensor and image analysis method could detect E. coli O157:H7 in 20 min, which is significantly quicker than conventional plate counting method.

Keywords

References

  1. Cho, H. K., G. Y. Kim, W. H. Kim and M. S. Sung. 2010. Detection of Pathogenic Salmonella Using a Surface Plasmon Resonance Biosensor. J. of Biosystems Eng. 35(2):116-123. https://doi.org/10.5307/JBE.2010.35.2.116
  2. Chua, A., C. Y. Yean, M. Ravichandran, B. Lim and P. Lalitha. 2011. A rapid DNA biosensor for the molecular diagnosis of infectious disease. Biosensors and Bioelectronics 26(9):3825-3831. https://doi.org/10.1016/j.bios.2011.02.040
  3. Hart, R. W., M. G. Mauk, C. Liu, X. Qiu, J. A. Thompson, D. Chen, D. Malamud, W. R. Abrams and H. H. Bau. 2011. Point-of-care oral-based diagnostics. Oral Diseases 17:745-752. https://doi.org/10.1111/j.1601-0825.2011.01808.x
  4. Hossain, S. M. Z., C. Ozimok, C. Sicard, S. D. Aguirre, M. M. Ali, Y. Li and J. D. Brennan. 2012. Multiplexed paper test strip for quantitative bacterial detection. Anal. Bioanal. Chem. 403:1567-1576. https://doi.org/10.1007/s00216-012-5975-x
  5. Karch, H., P. Tarr and M. Bielaszewska. 2005. Enterohaemorrhagic Escherichia coli in human medicine. Int. J. Med. Microbiol. 295(6-7):405-18. https://doi.org/10.1016/j.ijmm.2005.06.009
  6. Kim, G., G. M. Yang, Y. H. Kim, C. Y. Mo and S. B. Park. 2010. Detection of Pathogenic Salmonella with a Composite Quantum Dot. J. of Biosystems Eng. 35(6):458-463. https://doi.org/10.5307/JBE.2010.35.6.458
  7. Kim, G., G. Yang, S. B. Park, Y. H. Kim, K. J. Lee, J. Y. Son, H. J. Kim and S. R. Lee. 2011. Rapid Detection Kit for Salmonella typhimurium. J. of Biosystems Eng. 36(2): 140-146. https://doi.org/10.5307/JBE.2011.36.2.140
  8. Kim, G., J. H. Moon and M. Morgan. 2013. Multivariate data analysis of impedimetric biosensor responses from Salmonella typhimurium. Analytical Methods. 5: 4074-4080. https://doi.org/10.1039/c3ay40256h
  9. Kuang, H., G. Cui, X. Chen, H. Yin, Q. Yong, L. Xu, C. Peng, L. Wang and C. Xu. 2013. A one-step homogeneous sandwich immunosensor for Salmonella detection based on magnetic nanoparticles (MNPs) and quantum dots (QDs). Int. J. Mol. Sci. 14:8603-8610. https://doi.org/10.3390/ijms14048603
  10. Posthuma-Trumpie, G. A., J. Korf and A. Amerongen. 2009. Lateral flow (immuno)assay: its strengths, weaknesses, opportunities and threats. A literature survey. Anal Bioanal. Chem. 393:569-582. https://doi.org/10.1007/s00216-008-2287-2
  11. Radke, S. A. and E. C. Alocilja. 2005. A high density microelectrode array biosensor for detection of E. coli O157:H7. Biosens. Bioelectron. 20:1662-1667. https://doi.org/10.1016/j.bios.2004.07.021
  12. Su, X. and Y. Li 2004. Quantum dot biolabeling coupled with immunomagnetic separation for detection of Escherichia coli. O157:H7. Anal. Chem. 76:4806-4810. https://doi.org/10.1021/ac049442+
  13. Varshney, M. and Y. B. Li. 2007. Interdigitated array microelectrode based impedance biosensor coupled with magnetic nanoparticle-antibody conjugates for detection of Escherichia coli O157:H7 in food samples. Biosens. Bioelectron. 22:2408-2414. https://doi.org/10.1016/j.bios.2006.08.030
  14. Wang, D. B., B. Tian, Z. P. Zhang, J. Y. Deng, Z. Q. Cui, R. F. Yang, X. Y. Wang, H. P. Wei and X. E. Zhang. 2013. Rapid detection of Bacillus anthracis spores using a super-paramagnetic lateral-flow immunological detection system. Biosens Bioelectron. 42:661-667. https://doi.org/10.1016/j.bios.2012.10.088
  15. Wang, H., Y. Li and M. Slavik. 2007. Rapid detection of Listeria monocytogenes using quantum dots and nanobeads-based optical biosensor. Journal of Rapid Methods & Automation in Microbiology 15:67-76. https://doi.org/10.1111/j.1745-4581.2007.00075.x
  16. Zhu, H., U. Sikora and A. Ozcan. 2012. Quantum dot enabled detection of Escherichia coli using a cell-phone. Analyst 137:2541-2544. https://doi.org/10.1039/c2an35071h

Cited by

  1. A Review on Lateral Flow Test Strip for Food Safety vol.40, pp.3, 2015, https://doi.org/10.5307/JBE.2015.40.3.277